Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC NOT SPECIFIED | ₹30.3 L | L1 | Accepted-AOC low rate |
| 2 | L2₹36.8 L+₹6.4 L (21.3%)Rejected-Finance MANSA | BATHINDA | PUNJAB | 151302 | ₹36.8 L+₹6.4 L (21.3%) | L2 | Rejected-Finance high rate |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
15 Apr 2025, 12:00 pmClosed
Divisional Engineer
13-A,Canal Colony, Phase-1, Urban Estate, Dugri,
Lining and Relining of w/c of Outlet RD 24812 L of Khota Mr of Raunta Disty Vill Raunta (Laying and Jointing of RCC UGPL system and other allied works in construction of watercourse)
2025_WR_136489_11
PWRMDC/NIT 04 of 2025/DT.12.03.2025
Open Tender
Civil Works
Item Rate
180 days
Moga
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
₹60,000
Yes
Ludhiana
5 May 2025
13 Mar 2025
15 Apr 2025
13 Mar 2025
15 Apr 2025
13 Mar 2025
18 Mar 2025
Amount
Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. upto 1.5 mtr depth
Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. from 1.5 to 2.25 mtr depth
Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. from 2.25 to 3.00 mtr depth
Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. from 3.00 to 4.5 mtr depth
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
First class brick masonary 229 mm thick laid in cement sand mortar 1.6 in foundation and plinth including supply recarriage of bricks cement .
10mm thick cement plaster 1.4 on sides walls (-) Rs.1.25/- for scaffolding.
10mm thick cement plaster 1:4 on bed and top.
Reinforced cement concrete 1:2:4 hand mixed but including steel reinforcement
Cement Conc.1:2:4 including supply, carriage & with stone ballast or shingle
Cement concrete 1:4:8 with brick ballast 40mm gauge
Lowering, jointing and cutting of RCC NP-2 plain end pipes 250mm dia with RCC collars and laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect
Lowering, jointing and cutting of RCC NP-2 plain end pipes 300mm dia with RCC collars and laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect
Lowering, jointing and cutting of RCC NP-2 plain end pipes 350mm dia with RCC collars and laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect
Lowering, jointing and cutting of RCC NP-2 plain end pipes 400mm dia with RCC collars and laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect
Lowering, jointing and cutting of RCC NP-2 plain end pipes 450mm dia with RCC collars and laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect
Lowering, jointing and cutting of RCC NP-2 plain end pipes 500mm dia with RCC collars and laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect
Lowering, jointing and cutting of RCC NP-2 plain end pipes 600mm dia with RCC collars and laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect
Lowering, jointing and cutting of RCC NP-2 plain end pipes 150 mm dia for vent pipe into Trenches and laying same to correct alignment as per IS 458:2003( @2.5 metre / No) --
Wrought Iron and mild steel ladders, framed grills, grating etc. complete fixed in position in D-tank.
Providing & fixing M.S. foot rests made of 23x25 mm square bar including fixing in manholes complete with cement concrete 1:2:4
Providing and fixing of Alfa Alfa Valve 250mm fitted on riser pipe to act as Nakka (D-Regulators)
Providing and fixing of Alfa Alfa Valve 300mm fitted on riser pipe to act as Nakka (D-Regulators)
Providing and fixing of Alfa Alfa Valve 350mm fitted on riser pipe to act as Nakka (D-Regulators)
Providing and fixing of Alfa Alfa Valve 400mm fitted on riser pipe to act as Nakka (D-Regulators)
Providing and fixing of Alfa Alfa Valve 450mm fitted on riser pipe to act as Nakka (D-Regulators)
Providing and fixing of Alfa Alfa Valve 500mm fitted on riser pipe to act as Nakka (D-Regulators)
Providing and fixing of Alfa Alfa Valve 600mm fitted on riser pipe to act as Nakka (D-Regulators)
Centreing &shuttering for Concerte faces
Providing & Fixing of steel shutter gates assembly in main pipeline complete in all respect (250 mm dia)
Providing & Fixing of steel shutter gates assembly in main pipeline complete in all respect (300 mm dia)
Providing & Fixing of steel shutter gates assembly in main pipeline complete in all respect (350 mm dia)
Providing & Fixing of steel shutter gates assembly in main pipeline complete in all respect (400 mm dia)
Providing & Fixing of steel shutter gates assembly in main pipeline complete in all respect (450 mm dia)
Providing & Fixing of steel shutter gates assembly in main pipeline complete in all respect (500 mm dia)
Providing & Fixing of steel shutter gates assembly in main pipeline complete in all respect (600 mm dia)
Dismantling of Brick work in cement
DEEPAK SINGLA CONTRACTOR (BID ID -634004)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .