Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.1 L+₹25,720 (1.24%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹23.0 L+₹2.2 L (10.6%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L3 | Rejected-Finance L3 | |
| 4 | L4₹25.0 L+₹4.2 L (20.1%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹28.8 L+₹8.0 L (38.3%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹30.0 L
EMD Value
₹59,920
Closing Date
1 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN 914134 c/o 56 APO
REPAIR AND MAINT OF HT DISTRIBUTION SYSTEM AND ALLIED WORKS AT KHANABAL AND KHUNDRU UNDER GE 861 EWS
2022_MES_532556_2
134 WE-25(T)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Srinagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 861 EWS
₹59,920
Yes
6 Dec 2022
12 Aug 2022
3 Sept 2022
12 Aug 2022
1 Sept 2022
19 Aug 2022
13 Aug 2022 - 17 Aug 2022
Amount
Dismantling and taking out steel pole of any size, fixed in any position and removal from site, complete all as specified and directed by Engr-in-Charge.
Supply, fixing and erection in vertical position steel tubular swaged poles type 410, SP-55 (11 metres long) with 300mm x 300mm x 6mm thick mild steel base plate continuously welded to pole, MS plate 3mm thick finial taper plug bolt, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded position and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer on remaining exposed surfaces and making alternate black and white strips 30cm high with super enameled paint upto 1.5 mtrs height from ground level/ coping after erecting, complete all as specified and directed. Note : Earth work, PCC shall be measured and paid separately under relevant items.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 mtr deep, for laying cables/ pipes/ poles/stay etc and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-charge.
All as per Ser item No 3.00 here-in-above but depth exceeding 1.5 mtr and not exc 3 mtr.
Returning, filling in, spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removing surplus material (soil) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and directed by Engr-in-Charge.
Supply and laying in trenches fine river sand including spreading/ levelling, cushioning to underground cables 8cm before laying and 15cm after laying the cable and streching the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured.
Supply and laying in replacement reinforced precast concrete cable cover, class HV, type 2, flat of size 450mm x 180mm x 40mm, complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates) as in foundation of pole/stay etc, complete all specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping of pole etc including necessary form work, complete all as specified and directed by Engr-in-Charge.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm, complete all as specified and directed by Engr-in-Charge.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm, complete all as specified and directed by Engr-in-Charge.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed by Engr-in-Charge.
M&L in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (HD) with standard aluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm 3 core, complete all as specified and directed.
S&F in replacement galvanised strip of size 32mm x 6mm, burried in ground upto 50cm depth or fixed to wall with insulators etc for loop earthing including welding for joints, complete all as specified and directed. Note:- Earth work will be measured and paid seperately under relevent items.
S&F in replacement GOD triple pole, 11000 volts, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 Amps with drop out fuse, complete all as specified and directed.
S&F disc type insulator, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11 KV volts including taking down old unserviceable one, complete all as specified and directed by Engr-in-Charge.
S&F Pin type white, brown and green insulator including one galvansied mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm high, 150mm dia for 11000 volts grade including taking down old unserviceable one, complete all as specified and directed.
S&F galvanised stay wire of size 7/4mm complete, including taking down the old unserviceable stay wire, complete all as specified and directed.
S&F in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
S&F in replacement danger notice plate of size 25 x 20cm for HT, made out of 1.6mm thick mild steel sheet, vitreous, enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25 x 3mm MS flat fixed with iron, bolts and nuts, complete all as specified and directed by Engr-in-Charge.
Supply and laying 20mm graded coarse stone aggregate all around of the HT poles/ feeder panel/ station etc of bed 45cm thick, complete all as specified and directed by Engr-in-Charge.
S&F in replacement lighting arresters expulsion type complete with all fittings, suitable for 11 KV volts and discharge capacity 65 Kilo Amps, complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to the Galvanised iron strip of size 32mm x 6mm by means of bolts, nuts, check nuts and washers, protected by GI tube light grade of 40mm bore including provision of concrete pit in PCC 1:2:4 type B-1 with 40mm thick cover of RCC (1:2:4) reinforced with XPM, weight not less than 4 Kg /Sqm and 6mm dia round bar handle, excavation and earth work in any type of soil, charcoal dust and salt, 20mm bore GI watering pipe of light grade with funnel and wire mesh, complete all as shown in electrical plate No 3 of MES SSR Sch 2009 Part-I and all as directed by Engr-in-Charge. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metre shall be deemed to included in the quoted rate. (ii) On testing after completion if desired resistance is not obtained, the contractor shall redone the earthing without any extra cost to the department.
Disconnecting HT/ LT side electrical connection carefully existing 11 KV/ 440 Volts stepdown transformer of any capacity, draining out of existing transformer oil after filtration, dehydration and measuring the die-electric strength not less than 40 KV at 2mm gap including reinstallation of transformer satisfactory on its original position, connecting, testing and commissioning, complete all as specified and directed by Engr-in-Charge.
Supply and Filling in with new transformer oil, low viscosity of approved make as per IS-335 of 1993 and die-electric strength 30 KV when tested at 4mm gap, complete all as specified and directed. Note:- Contractor shall submit the certificate of desire value of die-electric strength from IS approved lab.
S&F in replacement breather assembly CI body of standard size, filled with silica gel of transformer up to 200 KVA capacity, complete with nuts, bolts and washers, complete all as specified and directed.
M&L for strip opening of transformer and removing the top cover for inspection, draining the transformer oil and taking out the core along with HT/ LT coil (Winding) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated new transformer oil and connection with existing electrical system HT/ LT and commissioning compete on load of capacity not exceeding 200 KVA, complete all as specified and directed. Note :- (i) Transformer oil will be measured and paid separately.
M&L for winding of HT/ LT coil of different type, capacity and make of transformer with approved quality super enameled copper wire of approved make of suitable gauge and number of turns along with allied materials like cork steel, fiber glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc, complete all as required at site and directed by Engr-in-Charge.
M&L for re-conditioning of LT coil of aluminium/copper wound transformer by turning the old paper insulations, strainghtening the entire LT strip providing new paper insulations of superior quality and making coil of suitable design as original, complete all as specified and directed by Engr-in-Charge.
S&F in replacement HT buses porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal, suitable for transformer of capacity upto 200 KVA, complete all as specified and directed by Engr-in-Charge.
S&F in replacement LT buses porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal for indoor/outdoor transformer of capacity not exceeding 200 KVA, complete all as specified and directed by Engr-in-Charge.
S&F in replacement top gasket, made of 3mm thick cork sheet with suitable holes including providing suitable size of bolts, nuts and washer for transformer top cover complete for any transformer of capacity upto 200 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement tapping switch/ gear and changer machanism for variation of HT voltage in steps for transformer of capacity not exceeding 200 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement breather assembly plastic body of standard size filled with silica gel of transformer of capacity not exceeding 200 KVA, complete all as specified and directed by Engr-in-Charge.
M&L for stay assembly, 20mm dia stay rod complete with accessories as shown is electrical plate No 1, complete all as specified and directed. NOTE:- Loop type insulator, stay clamp, excavation and concrete work shall be measured and paid under relevent item of BOQs seprately.
S&F cradle ground, hexagonal/ rectangular, fabricated with galvanized steel wire of 4mm dia for road crossing etc, complete all as specified and directed.
S&F in replacement loop type porcelain vitreous white, brown or green, large size with overall dimension 90mm x 140mm with hole 52.5mm, complete all as specified and directed.
S&F aluminium conductor steel reinforced of any size, fixed in over head lines on HT poles including stretching the aluminium conductor and binding with binding wires of aluminium or aluminium tapes etc. Jumpers and connections incuding taking down old existing conductor of any type, complete all as specified and directed by Engr-in-charge.
Stretching the aluminium conductor on overhead line/trimming of bushes, tress (8 ft near to over head HT line) HT pole and binding with binding wire of aluminium or aluminium tapes etc. jumpers and connections, complete all as specified and directed by Engr-in-Charge. Notes :- (a) Necessary shut down to be taken by contractor from 33 KV/ 11 KV MRS before execute the work. (b) Stretching of each conductor between two pole will be treated as one job.
M&L for servicing of HT 11KV, VCB installed at various locations including calibration by dismantling, cleaning, greasing the complete VCB with attached relays, bus bar etc, insulation testing, setting the contractor gap by measuring as required, reassembling the VCB and reinstalling back to its original position, checking and repairing the current, circuit panel wiring, relay testing (i.e. Primary and Secondary injection test)/setting of relay rating in 06 months intervals of all CT's and submitting the test report to Engr-in-Charge including provision of new spares parts as required complete including operational testing and commissioning and directed by Engr-in-Charge. Notes:- (a) New spares parts, if required for repair/serviceing of VCBs will be measured and paid separately under relevent item of BOQ. (b) Caliberation of relays and primary and secondary injuction test shall be conducted by rep of OEM/ State Inspection Dept of SED. Certificate of authority shall be produced by the SED/ OEM.
Supply only following spares for VCBs 33/11 KV of existing make :-
Resin encapsulated Vacuum bottles suitable for 11 KV VCB panel of capacity 400 Amp upto 25 KA as per existing.
Clossing coil 30V DC.
Tripping coil 30V DC.
11 KV porcelain bushing for VCB top/buttom.
Indicator bulb 20 watt 1100 volts as per existing make & specification sutiable for 400 Amps VCB, including necessary connection.
S&F in replacement of epoxy resin cast CT dual core of ratio as per existing accuracy class 0.055 buden 200/100/05vA for 11 KV, complete all as specified and directed. Make:- Vishal/Crompton/concord.
Operating switch (ON-OFF Lever) assembly.
Manual charging/operating gear system assembly with operating handle of complete assembly.
Digital type earth fault & over current relay, equivalent of L&T Mode No MC61A 24-110V.
Supply and filling transformer power oil of BDV not less than 45 KVA for topping up reduced level due to evaporation/leakage/loss due to dehydration in HT transformer, complete all specified and directed by Engr-in-Charge. Make : Power link/ Power oil/ Savita/ Midel.
S&F in replacement cable route indicator, made out of 50x50x6mm angle iron, 600mm long embedded in PCC block of suitable size with moulded letter ''HT cable'' suitable inscribed including PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) block of size 150x150x150mm, complete all as specified and directed by Engr-in-Charge.
M&L for GI tubing light grade 80mm bore with all fittings, laid in trenches or fixed on wall, along with pole for protection of cable including taking up or down old existing water tube, complete all as specified and directed by Engr-in-Charge.
M&L for preparation of surface of HT pole after removing existing treatment and applying two coats of synthetic enamel paint, complete all as specified and directed. Note :- Painting of one pole will be treated and measured as one Job.
Concept Engineering & Constructions
M/S Sky Engineers
M/S AK ENTERPRISES
M/S YATTOO CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .