Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC VEER SAVAKAR SARANI BANKURA | L1 | Accepted-AOC AOC | |
| 2 | L2₹1.6 L+₹4,058 (2.62%)Rejected-Finance 211 2 NARAYANTALA EAST BAGUIHATI KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance AS L2 BIDDER | |
| 3 | L3₹1.6 L+₹5,310 (3.43%)Rejected-Finance 11 PRATAPADITYAPLACE KOLKATA 700026 | L3 | Rejected-Finance AS L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹3,200
Closing Date
5 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT ENGINEER, CMSD,PHED
AE,CMSD,PHED,5TH FLOOR, PURTA BHAVAN
eplacement-of-damaged-pumping-machinery-and-other-electro-mechanical-works-at-Satgachia-Zone-I-PH-No-1-water-supply-scheme-under-CMD-PHE-Dte
2022_PHED_424371_9
WBPHED/AE/CMSD/eNIT_01/2022-23
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
SATGACHIA
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,200
AE,CMSD,PHED,5TH FLOOR, PURTA BHAVAN
30 Dec 2022
25 Nov 2022
8 Dec 2022
25 Nov 2022
5 Dec 2022
28 Nov 2022
28 Nov 2022
Amount
Thorough cheking of all electrical & mechanical accessories for brake down of pumping machinery as per direction of EIC.
Hiring charges of derrick set for withdrawing of pumping machinery as per direction of EIC.
Withdrawing of damaged 12.5HP Pump motor set along with 85ft. Long 3" dia. UPVC column pipe, 5ft. Long 3" dia. M.S. column pipe antisnapping device etc. by hired derick arrangement after disconnection of all electircal and pipe line connection complet as per direction of EIC.
Supply & delivery of the following Pumping machinery, Electrical accessories etc. at site. a) Submersible Pumping Machinery, directly coupled with suitable size water proof motor having following specifications. P U M P DISCHARGE (33 M3/H) H E A D (62 mtr.) S H A F T. Stainless Steel. OUTLET SIZE. 80mm. PUMP EFFICIENCY IN PERCENTAGE: Minimum 65. M O T O R (12.5HP) Submersible type, 3ph.50Hz, A.C.- 400Volt +10%, wet type winding, RPM-2900. SIZE OF TUBEWELL : (300mm. x 200mm.dia). and length of Housing pipe 44.00mtr. Pump motor set must be BEE standard energy star rating (3-5) as per IS – 8034:2002 Make-KSB/PLUGA/B.G./TEXMO/ Approved Make). N.B.;- (I) H/Q Characteristic Curve of pump set should be submitted before delivery. (II) Test certificate of pump & motor should be submitted during delivery & G.C.
Supply & delivery of following materials at site for installation of pumping machinery.
a)12" x 12 " rubber Sheet
b) 5/8" X 3" all thread nut, bolt with washer
Installtion of above new 12.5HP pumping machinery along with 85ft. Long 3" dia. UPVC column pipe, 5ft. Long 3" dia. M.S. column pipe antisnapping device etc. and item no. 5(a-b) by hired derick arrangement and making all electrical and pipe line connection complete as per direction of EIC.
Dismantling Manual Pannel part by part and damaged main switch for repairing and checking throughly as per direction of EIC.
Spply & delivey of the following Materials for replacement of damaged materials.
a)100 A TPN Main Switch with re-wirable fuse link within sheet steel enclosure(make (Havels/Standard/Approved Make)
b) 96 sqmm, Digital Type, Ampmeter 0-60Amp., AC use (Make: AE/Appproved Make)
c) Single phase preventor VSP3 (Make: Minilack).
d) R.Y.B. Indicator Lamp LED type (Make : ABB/Approved make)
Repairing of Manual panel and damaged main switch with above items (item No. 8 (a to d) and necessary wiring materials as per direction of EIC.
Supply and delivery of 20 watt, LED Tube Light (Make-phillips/ other approved make) (P.H. No. 1&2)
Supply & fitting fixing of 20 watt, LED Fixture set ----------for Phillips Model no. BRP 020/10 LED (Make: Phillps/ Other Approved Make) with 40mm. dia. × 2.5mtr. long G.I pipe bracket fixing on wall of the Pump House with 3nos. M. S. clamp properly grouting including making power connection with supply and drawing 2.5sq.mm. copper flexible cable wire with controlling sub switch and continuous earthing from nearest junction board all complete as per direction of E.I.C. (P.H. No. 1&2)
Add. GST@18%
Add. Cess@1%
P K ENGINEERING
POLYCON ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .