| 1 | L1₹32.6 LAccepted-Finance HOUSE NO 97 MOHALLA AFGHANA GALI KRISHAN DWARA JAMMU | JAMMU | JAMMU | JAMMU AND KASHMIR | ₹32.6 L | L1 | Accepted-Finance Being lowest bidder. |
| 2 | L2₹33.7 LRejected-Finance 195 BALLABHBARI GUMANPURA GUMANPURA KOTA RAJASTHAN 324007 UDYAM RJ 17 0172124 | KOTA | RAJASTHAN | 324007 | ₹33.7 L | L2 | Rejected-Finance Other than lowest bidder. |
| 3 | L3₹41.5 LRejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | ₹41.5 L | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹43.9 LRejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | ₹43.9 L | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Sona Enterprises L2 | M/S RAVI KUMAR L1 | S S BUILDERS L4 | M/S TRADE LINK L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Replacement of unsv/broken by new solar photo voltaic modules panel type/model MBSLeLITE 60, 254.79watt, rated voltage 30.89 V, rated current 8.25 Amp, crystalline silicon PV modules with spare/parts required for smooth functioning, tightenining of electric connection complete and assembling and reconnecting all as per site requirment all as specified and directed by Engr-In- Charge. | 20 | Each | 1,800 ₹36,000 | 8,000 ₹1.6 L | 12,000 ₹2.4 L | 5,000 ₹1 L |
| 2.00 | Repair/Servicing of Off grid inverter outdoor type incl replacement of unsv parts, IP-65 protection, 200 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, AC power string inverter on three phase side output voltage 415 V(+12.5%, 20% VAC) maximum current ripple 4% PP Reactive power 0.95 inductiveto 0.95 capacity, harmonic distortion less than 3% over all efficiencyof not less than 98%and above at full loadwith all protection (IEC61683), Operating temperature range -30 Degree Celcius to 60 Degree Celcius including making connection as per existing complete all as per site requirment all as specified and directed by Engr-In- Charge.The cost of replacement of unsv parts measured separately. | 2 | Each Job | 3,600 ₹7,200 | 500 ₹1,000 | 1,00,000 ₹2 L | 1,40,000 ₹2.8 L |
| 2.10 | IGBT | 2 | Each | 2,250 ₹4,500 | 1,000 ₹2,000 | 85,000 ₹1.7 L | 15,000 ₹30,000 |
| 2.20 | DC Relay | 2 | Each | 1,500 ₹3,000 | 3,000 ₹6,000 | 40,000 ₹80,000 | 5,000 ₹10,000 |
| 2.30 | Boosting Capacitor | 2 | Each | 1,500 ₹3,000 | 4,000 ₹8,000 | 10,000 ₹20,000 | 5,000 ₹10,000 |
| 2.40 | EMI Filter | 2 | Each | 2,100 ₹4,200 | 1,000 ₹2,000 | 20,000 ₹40,000 | 2,500 ₹5,000 |
| 3.00 | Dismantling and taking down old u/s earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
(ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC.
(iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost. | 5 | Each set | 3,600 ₹18,000 | 1 ₹5 | 5,000 ₹25,000 | 7,000 ₹35,000 |
| 4.00 | Dismantling and taking down old u/s earthing and Material and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and as directed.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
(ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC.
(iii) On testing after completion if the desired earth resistance ismore than 2Ώ the earthing will be redone at no extra cost | 5 | Each set | 3,300 ₹16,500 | 4,000 ₹20,000 | 5,000 ₹25,000 | 7,000 ₹35,000 |
| 5.00 | Dismantling and taking down old u/s earthing complete with copper earth plate 600mm x 600mmx 3.15mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 20x3 mm Copper strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
(ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC.
(iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost | 2 | Each | 15,000 ₹30,000 | 1 ₹2 | 20,000 ₹40,000 | 32,000 ₹64,000 |
| 6.00 | Replacement and fixing only Copper strip 20x3 mm from earth electrode to test point complete all as specified and directed. | 180 | RM | 90 ₹16,200 | 230 ₹41,400 | 300 ₹54,000 | 700 ₹1.3 L |
Updated dates
Tender Value
₹44.9 L
EMD Value
₹90,000
Closing Date
11 Apr 2026, 6:00 pmClosed
GE 860 EWS
GE 860 EWS PIN-913860
REPAIR MAINT OF SOLAR POWER PLANT AND CONNECTED ITEMS AND LT PANEL BOARD, FEEDER PILLAR BOXES, JUNCTION BOXES, REMOVAL OF LT PANEL BOARD AND CONNECTED WORKS SERVICES AT SHESHARTHANG AREA UNDER GE 860 EWS
2026_MES_755512_1
8144/2026-27/E8
Open Tender
Civil Works
270 days
Shesharthang
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS
₹90,000
15 Apr 2026
7 Mar 2026
13 Apr 2026
7 Mar 2026
11 Apr 2026
23 Mar 2026
Replacement of unsv/broken by new solar photo voltaic modules panel type/model MBSLeLITE 60, 254.79watt, rated voltage 30.89 V, rated current 8.25 Amp, crystalline silicon PV modules with spare/parts required for smooth functioning, tightenining of electric connection complete and assembling and reconnecting all as per site requirment all as specified and directed by Engr-In- Charge.
Repair/Servicing of Off grid inverter outdoor type incl replacement of unsv parts, IP-65 protection, 200 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, AC power string inverter on three phase side output voltage 415 V(+12.5%, 20% VAC) maximum current ripple 4% PP Reactive power 0.95 inductiveto 0.95 capacity, harmonic distortion less than 3% over all efficiencyof not less than 98%and above at full loadwith all protection (IEC61683), Operating temperature range -30 Degree Celcius to 60 Degree Celcius including making connection as per existing complete all as per site requirment all as specified and directed by Engr-In- Charge.The cost of replacement of unsv parts measured separately.
DC Relay
Boosting Capacitor
EMI Filter
Replacement and fixing only Copper strip 20x3 mm from earth electrode to test point complete all as specified and directed.
Replacement and fixing only GI earth strip 25x4 mm from earth electrode to test point complete all as specified and directed.
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge. Make: Havells/Sintex.
Supply & fixing in replacement of Integral LED Flood light Luminaries 100 Watts consisting of suitable number of LEDs and mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens, IP 66 protection suitable for mast light mounting, 5700K, LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV , Confirm the tests from auth labs : LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge.
Supply and fixing in replacement or passing through PVC conduit pipe of single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed.
Supply and fixing in replacement MCCB TPN 400 Amps, 415 Volts, 50 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 500 Amps, 415 Volts, 50 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 100 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
M&L Servicing and Cleaning of Off grid inverter indoor type, IP-65 protection, 200 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, including making fresh connection as per existing complete all as per site requirment all as specified and directed by Engr-In- Charge. Make: Optimal Model : Solar inverter GSC-200K(3P-0D-400-50-360-0K).
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and as directed.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc.
Description all as per item ser No 22.00 here in before but for 4 core 16 Sqmm
Description all as per item ser No 22.00 as per item ser No 22 here in before but for 3.5 core 35 Sqmm
Description all as per item ser No 22.00 as per item ser No 22 here in before but for 3.5 core 95 Sqmm
Description all as per item ser No 22.00 as per item ser No 22 here in before but for 3.5 core 150 Sqmm
Description all as per item ser No 22.00 as per item ser No 22 here in before but for 4 core 400 Sqmm
Material and labour for shifting heavy items / excavation / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley ect as required at site complete, all as specified and as directed.
Supply Only PVC braided hose pipe size 01 Inch complete all as specified and as directed.
Material and laying for Steel water tubes ISI marked, medium grade galvanised, with all fittings such as bends, elbows tees, slort, pieces, connections, back nuts,diminishing pieces caps, plugs and unions etc, laid in trenches or in floor with clamp including taking out of old unsv GI pipes complete of the following sizes :-
Description all as per item ser No 32.00 here-in-before but for 20 mm bore.
Description all as per item ser No 32.00 here-in-before but for 25 mm bore.
Description all as per item ser No 32.00 here-in-before but for 50 mm bore.
S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking out of old unsv gate valve complete of following sizes :-
Description all as per item ser No 33.00 here-in-before but for 20 mm bore
Description all as per item ser No 33.00 here-in-before but for 25 mm bore
DeDescription all as per item ser No 33.00 here-in-before but for 50 mm bore
Supply and fixing Rotational moulded polyethelene water storage tank triple layer ISI marked capacity 1000 ltr (cylinderical vertical with closed top) hoisted and fixed in position including making connection with existing pipeline complete all as per direction of Engr-in-Charge.
Supply and fix in replacement of Lithium based Energy Efficient Integrated Solar Street Light of 32 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 64/66Wp , Lithium Battery 11.1/12.8V, 33.0AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700°K - 6500°K, Microcontroller based charge controller cum driver, automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10°C to (+)55°C, weight not more than 16-18kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant including tubular pole 6 mtr height with bottom base plate 200x200x12 mm , outdoor dia not less than 65 mm with heavy duty GI pipe or steel thickness 3mm and suitable arrangement to mount solar light as directed on pole including foundation PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate and erection as per manufacturer drawing, providing synthetic enamel aluminium paint over one coat of red oxide complete all as specified and directed Make:- Axxon (AXN-32W) or equivalent of Phillips/Bajaj/wipro/havells
Supply and fixing in replacement of Inverter battery 12 volt, 150 AH, C-10 type, Solar Tubular type complete all as specified and directed by Engineer-in-charge.
Material and labour in replacement of broken earth pit of size 300x300x300 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result all as specified and directed.
Repairing of existing unserviceable PCC coping of supporting PCC blocks for solar paqnels by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash all as specified and directed.
Supply and fixing in replacement of Surge protection Device (SPD) DC 1000 Volt in DC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of DC Fuse 15 Amp in Surge protection Device (SPD) DC 1000 Volt in DC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Surge protection Device (SPD) AC in AC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of PVC insulated Solar DC cable 6 sqmm 1.8 KV DC volt for solar plant copper cable including taking down complete all as specified and directed by Engr-In-charge.
Supply and fixing in replacement of cable connector for solar DC cable 6 sqmm 1.8 KV DC volt for solar plant copper cable including taking down complete all as specified and directed by Engr-In-charge.
S&F, in replacement, MCCB, 415 volts, 04 pole, 63 Amps, 16 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : L&T / C&S / Indo Asian / Havells
S&F, in replacement, MCCB, 415 volts, 04 pole, 100 Amps, 35 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge.Make : L&T / C&S / Indo Asian / Havells
S&F, in replacement, MCCB, 415 volts, 04 pole, 160 Amps, 36 KA, adjustable type , including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : L&T / C&S / Indo Asian / Havells loadline
S&F, in replacement, MCCB, 415 volts, 04 pole, 200 Amps, 36 KA, adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : L&T / C&S / Indo Asian / Havells
S&F, in replacement, MCCB, 415 volts, 04 pole, 250 Amps, 36KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : L&T / C&S / Indo Asian / Havells
S&F, in replacement, MCCB, 415 volts, 04 pole, 400 Amps,36 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : Schneider / L&T / C&S / Indo Asian / Havells
S&F, in replacement, MCCB, 415 volts, 04 pole, 630 Amps, 50 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. Make : LT Cat Part No DN3- 630D / L&T / C&S / Indo Asian / Havells
Taking out old UNSV LT panel board / Junction box of any size complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 400 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 200 Amps, 415 Volt, AC ,25 KA = 02 Nos (O/G) (c) MCCB 4 pole, 160 Amps, 415 Volt, AC, 25 KA = 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts = 10 Nos (O/G) (d) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T (e) Phase indicating lamp = 03 Nos (R, Y, B) (f) Aluminium bus bar of capacity 600 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,35 KA = 01 Nos (I/C) (b) MCCB 4 pole, 160 Amps, 415 Volt, AC ,35 KA = 02 Nos (O/G) (c) MCCB 4 pole, 100 Amps, 415 Volt, AC ,35 KA = 02 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 11 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 250 Amps, 415 Volt, AC ,50 KA = 01 Nos (I/C) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 25 KA= 01 Nos (O/G) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 25 KA= 03 Nos (O/G) (d) MCB SPN 63 Amps, 230 Volts, AC = 04 Nos (O/G) (e) Multifunction meter MFM 4400 LED meter Cl 0.5S with RS485 Make : L&T (f) Phase indicating lamp = 03 Nos (R, Y, B) (g) Aluminium bus bar of capacity 400 amps four strip with colour coding should be shrinkable sleeves 4 Nos fixed on insulators-01 Set of four Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :- (a) MCCB 4 pole, 160 Amps,240/415 Volt, 50Hz, 10 KA= 01 Nos (I/C) (b) MCB SPN 63 Amps, 240 Volts - 04 Nos (O/G) Note : Unit rate quoted by the contractor here-in-before also includes for fixing and connecting of MCBs and installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the galvanised iron strip 32×6mm by means of bolts, nuts , check nuts and washers of galvanized iron and galvanised iron strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to MCBDB’s earth test point all as specified or indicated including testing on completion.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_846241.pdf
techsummary_846241.pdf
finance_846241.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender28144.pdf
Tender Documents • 0.91 MB
Tender18144.pdf
Tender Documents • 0.54 MB
Tender38144.pdf
Tender Documents • 0.31 MB
BOQ_846241.xls
BOQ • 6.84 MB
Download all tender documents and submit your bid