Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | LI₹1.2 CrAccepted-AOC | ₹1.2 Cr | LI | Accepted-AOC Successful Bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically not qualified |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
15 Sept 2022, 2:00 pmClosed
S.E. PWD Bldg. Circle Nalbari
S.E. PWD Bldg. Circle Nalbari
Establishment of Cold Storage(Cold Room) at the Campus of the Howly Regulated Market Committee
2022_PWBNH_26972_1
SENL(N)/P.N/8/2022-23/1017
Open Tender
Civil Works - Building
Item Rate
180 days
S.E. PWD Bldg. Circle Nalbari
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
₹2.4 L
Yes
8 Dec 2022
10 Sept 2022
15 Sept 2022
10 Sept 2022
15 Sept 2022
10 Sept 2022
10 Sept 2022 - 15 Sept 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered). Depth exceeding 1.5 m but not exceeding 3 m
Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered): Depth exceeding 1.5 m but not exceeding 3 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Along the external wall below concrete or masonry apron us-ing chemical emulsion @ 2.25 litres per linear metre includ- ing drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Dry brick on edge flooring in required pattern with bricks of classdesignation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Providing VDF flooring for top coat of floor with dewatering of concrete by vaccum pump and sprinkling non-metlic floor hardner @ 5Kg /sqm followed by a coat cement slurry mixed with Nitobond SBR latex or equivalent @ 1kg over 1.25 sq. mtr and 67 ml Nitobond SBR latex . Over the levelling reinforced cement concrete base 1.1.5:3 simultenious casted as per specification 10 mm x 12 mm grove @ 5 Mtr or equal distributed pattern to be cut and filted with Polysulphide Sealent as grounting cpompound complete and finished in all respect as per company specifcation and Engineer-in-chrage ( The RCC work wil be measured and paid separately)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Service cost of Technical expert/ Firm/consultant including drawing design etc as requred & directed by Engineer ( engaged by contrcctor) including tax etc as per APWD norms ( Agreement with Technical expert/Firm Conmsultant with the contrctor along with experinence Certificate of Technical expert/Firm/ Consultant will have to be produced)
Suplying installation testing comissioning of Cold storage and dryling yard as per the Architectural drawing and standard specifications ( note: The contator will be submitted the design an detailds darwing for HPCC work of obtain appreval from the authority before peoceding to execution) the general specificatins of HPCC,Insultation and Machineries are as per Annexute-I
Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 75 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. As required. 5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. As required. 6 pin 15/16 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. As required. 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. As required. 6 pin 15/16 A socket outlet
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Design, manufactire, supply, installation tresting and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel floor mounted totally enclosed switch board suitable for use of 415 volts, 3 phase, 50 Hz complete with aluminium bar-bar and all acccessories including suupply and fixing of following incoming and outgoing switchgears. The sheet steel shall undergo minium 7 tank treatment followed by finihsed powder coating of min 60 m micron thickness Incomer FP100 A 36 KA -Ics =100% Icu MCCB microprocessor based release with built in E/F protection, extended rotary handle and spreder terminal-2 Nos ( 1 for ASEB and other for Gnerator) Digital Ammeter 0-100 A 3 Phase 4 wire Accuracy Class-1 as per IEC 62053-21 Bezel diamention (W X H) =96x 96 mm 1 Nos CT 100/5 240V 3 Phase 4 wire Freq 50 Hz+/-5% Accuracy Class 0.5S :1 Set SP MCB with 10 KA breaking capacity of rating 6 Amps: 03 Nos EYB indicating Lamps 1 Set BUS BAR : 800 A TPN AL. Bar with coloured heat shrinkable PVC sleeve 1 Set 100 A 4P Manual Change over switch 1 No Outgoing 40 A 4P MCCB 25 KA - 2 Nos for AC power supply 32 A TP MCB 25 KA-1 No B- Series as spare 32 A DP MCB 25 KA-10 No B-Series for SBs and power points Earthing Bus Supply & Installation of Light Fitting/Fans / Air Conditioner/ Geyser / Luminaries and Fixture
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply nd Installation of 1200 sweep powerful double bearing ceiling fan. Make Orinet summer breeza or equivalent Havells or Panssomic make as approved
Supply of 400 mm High speed Oedestal fan, Make : Orient 400 mm stand 37
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly onceiling/ wall, including connections with 1.5 sq. mm FRLS PVCinsulated, copper conductor, single core cable and earthing etc. as required.
Supplying of following LED lighting fixture complete with Drive an Lamps with reflector /cover etc complete as required : 1 x 20 W LED T8 6500K retrofitting tube light fitting with drive and frame Make : CGL or Havells/ Siska equivalent philips as approved
Down light 6 Inch dia round recess 15 Watt LED W ( 6.5) light fittings for room lighting Make SISK-dls 6`` -15 W or equivalent CGL / HAVELS /SURYA as approved for room lighting ( 7 lights in each room)
Supplying of 40 W LED W IP65 light luminaries made out of dis case auiniu housing and head frame pwder coated in approved color incuding driver and accessories as required. Make Siska Ref Cat No SSK ST 45 W SN or equivalent GCL, Surya Havells as approved forout door ligitng as directed.
Supply of 40 W LED W IP65 Flood light made out of sia cast alumunium housing and head frame, powder coated in approved colour incuding driver and accessories as required. Make Siska Ref. Cat No SSK -BLS-CF-40W or equivalent CGL Surys, Heavels as approved for Coolong shade area as directed
Supply of following sizes of 1.1 KV grade single core/multicore Copper/aluminium conductor XLPE insulated and PVC sheated armoued/unarmoured cable conforming to IS 1554 ( Part-I) 1988 Make RR Kable, Havells, Polycab KEI or equivalent as approved 4 core 10 sq. mm x XLPE ARMOURED Copper for AC outdor unit form MDB
3.5 Core 70 Sq. mm XLPE ARMOURED aluminum Cable for Power supply from transfomer to MCB
4 core 50 Sq. mm XLPE ARMOURED Aluminium cable for Power supply from DG to MDB
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number additional PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing earth Bus bar joint made of 20 mm x3 mm thick 125 mm long with 6 Nos G.I. bolts, nuts chuck nut and spring washers etc complete as required
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40 mm dia
Providing and fixing M.V. danger notice plate of 200 mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and installation of 4.5 Kg Mil steel ABC type CO2 type fire extensuisher
Supplying Installation and Commissioning of following capacity 35 KVA 430 V, 3 Phase Slient Diesel Generator stes with auto run and auto changee over facility including earthing as required : Make Cummins of CGL as approved
Supplying and laying in position cement concrete 1:3:6 ( 1 cement : 3 course sand: 6 graded stone aggregated 20 mm nominal size) for above generator foundations etc. including frame works etc. as directed
Supplying installation testing and commissioing of the following rating copper wound out door type transformer. Transformer should be as per CEA/BIS guidelines as ammended up to date for losses along ith LV enclosure 63 KVA 50 Hz 11/0.433 KV Oil filled LEVEL 2.4 STATR COPPER WINDING transformer ( To be installed on pole structures)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required for transformer
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm)
Cost for Load Security
Construction of 11 KV line to site of Constrution ( As per APDCL ( includinig supervision Cost etc) ( L/S) payment will be made on the bsis of APDCL Bill/ Voucher/ Esimate)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .