Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.1 LAdmitted-Finance 11 E 379 11 PUL PEHLL 110044 | SOUTH EAST DELHI | DELHI | 110044 | -2.05% | ₹14.1 L | L1 | Admitted-Finance |
| 2 | L2₹14.2 L+₹15,111.98 (1.07%)Admitted-Finance | -1.00% | ₹14.2 L+₹15,111.98 (1.07%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical Not submitted as per NIT |
Tender Value
₹14.4 L
EMD Value
₹28,785
Closing Date
10 Jul 2026, 3:00 pmClosed
EE(E)/ELD-13/DDA
Executive Engineer (E), ELD-13/DDA, Near Hasanpur Bus Depot. Delhi. 110092
RMO of Compound lighting, PA System along with DG Set at Surbathing Ghat downstream of Yamuna river Wazirabad Barrage.
2026_DDA_915606_1
05/EE/ELD-13/DDA/2026-27(SPLZ) (Re-Re-Invited)
Open Tender
Electrical Works
Percentage
365 days
As per NIT documents.
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹28,785
EE(E)/ELD-13/DDA
10 Aug 2026
3 Jul 2026
13 Jul 2026
3 Jul 2026
10 Jul 2026
3 Jul 2026
6 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Running, opreation & maiteneance of DG set, PA system, re-wiring of speakers as per inventory, BOQ, terms and conditions attached. Deploying following staff etc. complete as reqd.
Opretor Gr-II - 1 No. daily
Wireman Gr-II -1 No. - 4 days a month
Khallasi-1 No daily | 12 | Month | 66,428 | ₹7,97,136 |
| 2 | LED Batten light (System lumen efficacy ≥105 85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) | 20 | Each | 681 | ₹13,620 |
| 3 | Servicing of existing installed DG set of 110 KVA from OEM ( Kirloskar Make) along with supply and replacement of worn out parts such as fuel filter kit, Airfilter, oilfilter, engine oil/Mobil oil, coolent , i/c testing, commissioning and cartage etc complete as required. | 1 | Job | 16,363 | ₹16,363 |
| 4 | Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.(1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ) | 4 | Each | 2,882 | ₹11,528 |
| 5Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA , "C" curve miniature circuit breaker suitable for inductive load of the following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||||
| 5.01 | Single Pole | 25 | Each | 285 | ₹7,125 |
| 5.02 | Double Pole | 8 | Each | 696 | ₹5,568 |
| 6Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. | |||||
| 6.01 | 32 A TP&N | 8 | Each | 2,292 | ₹18,336 |
| 6.02 | 63 A TP&N | 6 | Each | 3,342 | ₹20,052 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.25 MB
Tendernotice_2.pdf
PDF • 5.13 MB
BOQ_962211.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .