Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 1488 CHAMAN COLONY DHANAS CHANDIGARH | Admitted-Finance |
| 2 | Admitted-Finance CHANDIGARH CHANDIGARH | NA | NA | 160001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹37,280
Closing Date
21 Jan 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Principal
Principal Dr Jatinder Kaur
Construction of One Medical Room and One Common Reading cum Study Room in Guru Gobind Singh College for Women Sector 26 Chandigarh
2021_CHD_57841_1
GGSCW/2021/46
Open Tender
Civil Works
Item Rate
45 days
Guru Gobind Singh College for Women Sector 26 Chd
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
Principal Guru Gobind Singh College for Women
₹37,280
Yes
21 Jan 2021
13 Jan 2021
21 Jan 2021
13 Jan 2021
21 Jan 2021
13 Jan 2021
15 days
Amount
PART-A(CIVIL WORK)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(2.8)
All kinds of soil(2.8.1)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(2.25)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(2.27
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(4.1)
1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)(4.1.10)
Centering and shuttering including strutting, propping etc. and removal of form for :(5.9)
Foundations, footings, bases of columns, etc. for mass concrete(5.9.1)
Suspended floors, roofs, landings, balconies and access platform(5.9.3)
Lintels, beams, plinth beams, girders, bressumers and cantilevers(5.9.5)
Columns, Pillars, Piers, Abutments, Posts and Struts(5.9.6)
Stairs, (excluding landings) except spiralstaircases(5.9.7)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge(5.33)
(Note :- Cement content considered in this item is @ 320 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level(5.33.1)
All works above plinth level upto floor V level(5.32.2)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level(5.22A)
Thermo-Mechanically Treated bars of grade Fe-500D or more(5.22A.6)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:(6.1)
Cement mortar 1:6 (1 cement : 6 coarse sand)(6.1.2)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :(6.4)
Cement mortar 1:6 (1 cement : 6 coarse sand)(6.4.2)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessaryscrews.(9.9)
Kiln seasoned and chemically treated hollock wood(9.9.2)
35 mm thick(9.9.2.1)
providing and fixing 5mm thick clear glass of approved make in windows, ventilators etc(9.7.7.2)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:(9.21)
35 mm thick including necessary M.S. screws but excluding the cost of butt hinges (9.21.1)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :(9.27)
35 mm thick shutters(9.27.1)
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete(.9.83)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :(9.96)
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :(9.97)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :(9.1)
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.(9.101)
Twin rubber stopper(9.101.2)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:(10.14)
Profile E(10.14.3)
Fixing with adjustable lugs with split end tail to each jamb(10.14.3.1)
(Note- The centre mullion in any door and window frame will be counted and paid 1.5 times of outer section, for its clear length)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick(11.26.1)
kota stone slab 20 mm in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.(11.27)
Extra for pre finished nosing in treads of steps of Kota stone /sand stone slab. (11.31)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
In 75x75 mm deep chase(12.21.1)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.(12.22)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(12.41)
110mm diameter(12.41.2)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.(12.42)
110 mm bend(12.42.5.2)
12 mm cement plaster of mix :(13.1)
1:6 (1 cement: 6 fine sand)(13.1.2)
15mm cement plaster of mix :(13.16)
1:3 (1 cement : 3 fine sand)(13.16.1)
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. (13.42)
Two or more coats on new work.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (13.8)
Finishing walls with Acrylic Smooth exterior paint of required shade :(13.46)
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(13.46.1)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :(13.61)
Applying priming coat:(13.5)
With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)(13.50.1)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces, khurrahsetc using trapecrete or any parallel product by dr. fixit make including testing on ground. . (NS)
10 cm thick ( average ) mud phuska of damped brick earth on roof laid to slop consilidating and plastererd with 25 mm thick mud mortar with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 and covered with machinemoulded tile brick grouting with cement mortar 1:3 mixed with 2% of integral water proofing compound by weight of cement and finished neat.(12.16)
Extra for every additional 1 cm thickness of mud phuska. (12.18)
Providing and fixing M.S railing grills, guard bars etc. as & where requried consisitng of M.S flat/solid square bars/ M.S angle etc. as per architectural drawings & fixing in position including welding charges, cost of one coat of anit-corrosive metal primer & two coats of special quality paint of approved shade complete in all respect. (NS)
Demolishing R.C.C slab/jhaller, brick work, plaster, PCC flooring, tile terrace, removal of door window frame etc. and removal of malba as/site.
PART-C (ELECTRICAL WORK)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(1.25)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.(1.45)
Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)(2.9)
8 way Double door(2.9.4)
S&F SP MCB 5 to 32 amps suitable for 240/415 volts, "C" series MCB suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(2.10)
Triple pole and neutral(2.10.4)
Supply of PVC/XLPE insulated copper conductor armoured and served cable working voltage 1100 volt Grade through walls/ ceiling with appropriate clamps and fixing arrangements, cable tray etc. as per specifications and drawings.(NS)
4 Core 16 Sq.mm
BRIJ NANDAN
M/s Dayal Constructions
DHARMINDER KUMAR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .