Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹13.3 L+₹1.3 L (10.5%)Rejected-Finance PLOT NO 1 3RD CROSS STREET THENDRAL NAGAR MOOLAKULAM REDDIYAR PALAYAM POST PUDUCHERRY 605 010 | PONDICHERRY | PUDUCHERRY | 605010 | L2 | Rejected-Finance L2 Rejected | |
| 3 | L3₹13.4 L+₹1.4 L (11.7%)Rejected-Finance NO 4 85 MICRO STREET MORATTANDI VANOUR TALUK TAMILNADU 605 111 | VILLUPURAM | TAMIL NADU | 605111 | L3 | Rejected-Finance L3 Rejected |
Tender Value
₹12.9 L
EMD Value
₹25,862
Closing Date
1 Aug 2023, 10:30 amClosed
The Executive Engineer
3rd Floor, Department of ADW and STW, Thattanchavady, Puducherry
Special repairs and maintenance works to the Government Boys Hostel at Villianur, Puducherry.
2023_PADCO_13246_1
45/PADSTDC/EW/23-24
Open Tender
Civil Works
Works
Thattanchavady
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹25,862
7 Feb 2024
24 Jul 2023
1 Aug 2023
24 Jul 2023
1 Aug 2023
24 Jul 2023
Amount
Code No. 4.1.3: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20mm nominal size)
Code No.9.117.1: Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +_1mm ), with wall thickness 2.0 mm (+-0.2mm) , corners of the door frame to be jointed with galvanized brackets and stainless steel screws , joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 x 19 mm and 1mm (+-0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification - Extruded section profile size 48 x 40 mm
Code No.9.118.1: Providing and fixing to existing door frames - 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59 x 24 mm and wall thickness 2 mm (+- 0.2 mm) with inbuilt edging on both sides . The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws . The styles of the shutter reinforced by inserting galvanised M.S.tube of size 20x20 mm and 1mm (+- 0.1mm) wall thickness . The lock rail made up of 'H' section , a uPVC hollow section of size 100 x 24 mm and 2 mm (+-0.2 mm) wall thickness , fixed to the shutter styles by means of plastic / galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm (+_ 0.1mm) wall thickness . They panels filled vertcally and tie bar at two places by inserting horizontally 6 mm galvanised M.S.rod and fastened with nuts and washers , complete as per manufacturer's specification (For W.C. and bathroom door shutter)
Code No.12.41.2: Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter
Code No.12.42.5.2: Providing and fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree -110 mm bend
Code No.12.42.6.2: Providing and fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) -110mm shoe
Code No.12.43.2: Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs ,screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc.,complete - 110mm
Code No. 13.48.1: Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacture's specification -Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm
Code No. 14.43 : Removing white or colour wash by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete
Code No. 14.54.1 :Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work
Code No. 16.100 : Acid cleaning for the existing Mosaic floors , glazed tiles work and removing the stains and decays to give a glassy look etc complte (The Acid used shall be 32% concentrated hydrochloric acid after taking on the precautionary measures)
Code No. 31.161.1l (Addendum): Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore /Nandi) (0.6 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site ,lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excluding UPVC specials such as bends,tees, threaded pieces,couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 180mm dia.
Code No. 7259 : Supplying and fixing of C.P.brass long body bibcock
Code No.1.15.1 : Rewiring for light point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantling as required - GROUP A
Code No.1.15.2 : Rewiring for light point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantling as required - GROUP B
Code No.1.15.3 : Rewiring for light point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantling as required - GROUP C
Code No.1.22.2: Supplying and fixing metal box of following sizes (nominal per size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 100 mm x 100 mm x 60 mm deep
Code No.1.22.6:Supplying and fixing metal box of following sizes (nominal persize) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 200 mm x 125 mm x 60 mm
Code No.1.22.16:Supplying and fixing metal box of following sizes (nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 250 mm x 300 mm x 100 mm
Code No.1.23.1: Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc.as required - 5/6 A switch
Code No.1.23.3 :Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc.as required - 2 way 15/16 A switch
Code No.1.25 : Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required
Code No. 1.44 : Installation , testing and commissioning of ceiling fan , including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated , copper conductor ,single core cable etc as required
Code No. 1.50.1: Installation of exhaust fan in the existing opening , including making good the damage , connection , testing ,commissioning etc. as required - Upto 450 mm sweep.
Code No. 2.10.4 : Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Triple Pole
Code No. 2.13.2 : Supplying and fixing following rating , double pole , 240 V, Isolator in the existing MCB DB complete with connections ,testing and commissioning etc.as required - 63 A
Code No. 3131-O : Supplying of 450mm 1400 rpm heavy duty exhaust fan Make:Almonard/Orient/Usha.
Code No. NPSR : Suppling of ceiling fan sweep 1200mm Fusion-50 Energy saving fan Five star.Make: Havells (Rate appd No.605/PW/SEI/AE(P)-II/F.No.221/14-15/579 Dt. 02.02.2015)
Code No. NPSR: Supplying and fixing 4 feet, 20-24 W LED tube light fitting make :Philips/Wipro/Havells/Crompton. (Rate appd No.352/PW/SEI/AE(P)-I/F.No.CB312(ELEC)/2018-19/ Dt. 30.01.2019)
Code No. NPSR: Supplying and fixing of 48W LED Street Light Fitting (Philips/Havels/LEDGEO) etc., complete as directed by the Engineer-in-charge (Rate appd No.2735/PW/SE-II/AE(P)-6/SB-150/2022-23/1019 Dt. 27/07/2022).
NR CONSTRUCTION
S.VIJAYAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .