| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC KHATTA NO 503 KHASRA NO 233 ANSH TRADING COMPANY GOLE CAMP ROAD TALAB TILLO JAMMU JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | ₹25.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹28.5 LRejected-Finance 11 26 BHAGWANPURA KISHANGARH CHANDIGARH | ₹28.5 L | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | AVNET Solutions L2 | ANSH TRADING COMPANY L1 |
|---|---|---|---|---|---|
| 1.01 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] | 4,290 | Metre | 31 ₹1.3 L | 32 ₹1.4 L |
| 1.02 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 900 | Metre | 65 ₹58,500 | 55 ₹49,500 |
| 1.03 | SITC of 15 U Standard rack to place all Av equipment Make Valrack, Comrack,Hive Networks. (DSR 39.23.3) | 1 | Each | 15,600 ₹15,600 | 14,800 ₹14,800 |
| 1.04 | Supply,Erection testing and Commissioning of UTP cat 6 information outlet( RED - for Data - User End) and UTP Face plate complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:-Molex/RandM/D-Link (DSR 39.15) | 63 | Each | 310 ₹19,530 | 300 ₹18,900 |
| 1.05 | Supply,Erection testing and Commissioning of UTP cat 6 Mounting Patch Cords Low smoke zero helogene
(LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:-
Molex/RandM/D-Link. (DSR 39.12.1) 3 FT length | 63 | Each | 280 ₹17,640 | 260 ₹16,380 |
| 1.06 | Supply,Erection testing and Commissioning of UTP cat 6 Mounting Patch Cords Low smoke zero helogene
(LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:-
Molex/RandM/D-Link. 7 FT length (DSr 39.12.2) | 63 | Each | 310 ₹19,530 | 290 ₹18,270 |
| 1.07 | Supply,Erection testing and Commissioning of UTP cat 6 24 port jack pannel complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- Molex/RandM/D-Link. (DSR 39.11) | 4 | Each | 7,000 ₹28,000 | 7,200 ₹28,800 |
| 1.08 | Supply,Erection testing and Commissioning of Layer 2 Switch should have total 28 Nos. Gigabit port
including 24 Nos. of 10/100/1000 Mbps Ethernet Ports and 4 Nos. of dual personality (SFP/GbE) portsThe switch should be flexible enough to be managed through cloud and standalone mode. The cloud management should be free of cost The Switch should have Non-blocking wire speed switch
fabric, should have Min. 56 Gbps Back plane or more and should have Min. 41 Mpps or more, IPv6 Support, 16K MAC address, CE-LVD ,FCC, CE ,BSMI , RoHS Compliant,Operating temperature 0 DegC to 50 Deg C Should have Cluster Stacking to manage up to 24 switches by single IP addressThe OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these cerificates must be submitted in technical bid.Make- Cisco, Alcatel, Zyxel, Juniper (DSR 39.3.2) | 4 | Each | 79,200 ₹3.2 L | 75,900 ₹3.0 L |
| 1.09 | Supply,Erection testing and Commissioning ofng of Layer 3 Swith with 24x 100/1000 Mbps RJ-45 ports, 4x Dual personaliy GbE ports (SFP 100/1000 Mbps or RJ-45 10/100/1000 Mbps Ports, 4x SFP plus 10G Ports, Support Dual redundant power supply, 136 Gbps Switch fabric speed,, 101.10 Mpps Forwarding Rate , 32K MAC address table, Operation Temperature: 0° to 50° C, L3 Services - IPv4 Routing, RIP v1, v2, OSPF v2 ,L3 Services - IPv6 Routing, Multipath-ECMP, ANSI/UL 60950-1, FCC Part 15 (Class
A),CE EMC (Class A) IEC 60950-1,EMC, , iStacking (cluster) up to 24 switches, The OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these cerificates must be submitted in technical bid. Make- Cisco, Alcatel, Zyxel, Juniper (DSR 39.4) | 1 | Each | 1,98,600 ₹2.0 L | 1,92,800 ₹1.9 L |
| 1.10 | Supply,Erection testing and Commissioning of 1G SFP plus Transceiver for Single Mode Fiber complete in all respect up to the entire satisfaction of Engineer-in charge of work Make: Cisco, Alcatel, Zyxel, Juniper (DSR 39.6.2) | 8 | Each | 9,500 ₹76,000 | 7,500 ₹60,000 |
Tender Value
₹22.2 L
EMD Value
₹44,348
Closing Date
19 Jan 2026, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Setting up Court Rooms at second floor in SDO Civil Complex at Punhana in Nuh District.( Pdg. LAN, CCTV, Fire Alarm and PA system only)
2026_HRY_496377_1
2026C776743F F7D1 4AB9 81FC D28B23BFCDCF668BAR
Open Tender
Civil Works
60 days
Punhana
2 documents required · 2 mandatory
₹1,000
₹44,348
Yes
24 Mar 2026
12 Jan 2026
20 Jan 2026
12 Jan 2026
19 Jan 2026
12 Jan 2026
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
SITC of 15 U Standard rack to place all Av equipment Make Valrack, Comrack,Hive Networks. (DSR 39.23.3)
Supply,Erection testing and Commissioning of UTP cat 6 information outlet( RED - for Data - User End) and UTP Face plate complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:-Molex/RandM/D-Link (DSR 39.15)
Supply,Erection testing and Commissioning of UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- Molex/RandM/D-Link. (DSR 39.12.1) 3 FT length
Supply,Erection testing and Commissioning of UTP cat 6 Mounting Patch Cords Low smoke zero helogene (LSZH/LS0H )complte in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- Molex/RandM/D-Link. 7 FT length (DSr 39.12.2)
Supply,Erection testing and Commissioning of UTP cat 6 24 port jack pannel complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work Make:- Molex/RandM/D-Link. (DSR 39.11)
Supply,Erection testing and Commissioning of Layer 2 Switch should have total 28 Nos. Gigabit port including 24 Nos. of 10/100/1000 Mbps Ethernet Ports and 4 Nos. of dual personality (SFP/GbE) portsThe switch should be flexible enough to be managed through cloud and standalone mode. The cloud management should be free of cost The Switch should have Non-blocking wire speed switch fabric, should have Min. 56 Gbps Back plane or more and should have Min. 41 Mpps or more, IPv6 Support, 16K MAC address, CE-LVD ,FCC, CE ,BSMI , RoHS Compliant,Operating temperature 0 DegC to 50 Deg C Should have Cluster Stacking to manage up to 24 switches by single IP addressThe OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these cerificates must be submitted in technical bid.Make- Cisco, Alcatel, Zyxel, Juniper (DSR 39.3.2)
Supply,Erection testing and Commissioning ofng of Layer 3 Swith with 24x 100/1000 Mbps RJ-45 ports, 4x Dual personaliy GbE ports (SFP 100/1000 Mbps or RJ-45 10/100/1000 Mbps Ports, 4x SFP plus 10G Ports, Support Dual redundant power supply, 136 Gbps Switch fabric speed,, 101.10 Mpps Forwarding Rate , 32K MAC address table, Operation Temperature: 0° to 50° C, L3 Services - IPv4 Routing, RIP v1, v2, OSPF v2 ,L3 Services - IPv6 Routing, Multipath-ECMP, ANSI/UL 60950-1, FCC Part 15 (Class A),CE EMC (Class A) IEC 60950-1,EMC, , iStacking (cluster) up to 24 switches, The OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these cerificates must be submitted in technical bid. Make- Cisco, Alcatel, Zyxel, Juniper (DSR 39.4)
Supply,Erection testing and Commissioning of 1G SFP plus Transceiver for Single Mode Fiber complete in all respect up to the entire satisfaction of Engineer-in charge of work Make: Cisco, Alcatel, Zyxel, Juniper (DSR 39.6.2)
S/I/T/C of 6 core SM Optical fiber. Make:-Molex/RandM/D-Link (DSR 39.19.1)
S/I/T/C of 12 Port LIU. Make:-Molex/RandM/D-Link (DSR 39.21.2)
S/I/T/C of LC to SC Patch Cord. Make:- Molex/RandM/D-Link
S/I/T/C of SC SM Pigtail Make:-Molex/RandM/DLink
S/I/T/C of Fiber Adapter Make:- Molex/RandM/DLink
S/I/T/C of 3core 1.5sqmm power cable. Make: Havells, Polycab, Finolex (DSR 20.28.1)
Supply,Erection testing and Commissioning of 15 U rack with cable manager,fan tray,power distribution kit complete in all respect.Make: Comrack/Netrack/Wallrack (DSR 39.23.3)
Supply,Erection testing and Commissioning of 6 U rack with cable manager,fan tray,power distribution kit complete in all respect.Make: HCL/ Comrack/ Wallrack/ Netrack (DSR 39.23.1)
SITC of 3 KVA Online UPS Overvoltage cut-off device Support for up to external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window for Indian Environmental Condition andfor Optimized BatteryPerformance. 30 minutes back up MAKE APC/ LIBERT EINOVA/Microtek/Emerson (DSR 26.1.2)
SITC of Bullet 4MP to 5MP IP Camera (but not less than 4MP). 1/3` or better` progressive scan CMOS or better image sensor, supporting day/night operation with IR cut filter, minimum illumination 0.01 lux (color), 0 lux (B/W with IR). Motorized 2.8-12mm or better lens with remote zoom/focus, electronic shutter 1/100000s to 1/15s. Camera shall deliver 4 streams including Profile 1: Mainstream - 2560 x 1440 @ 30fps (H.265/H.264), Substream 2, Substream 3, Substream 4. Should have exposure controls (auto/manual), BLC, noise reduction, WDR (120dB or better). The camera shall support built-in analytics (motion detection, tamper, intrusion ), 50m IR, edge storage with minimum 512GB SD card slot (Class 10). Network protocols: IPv4/IPv6, HTTP, TLS, SMTP, SNMP, DNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP. Cyber security compliance: ISO/IEC 27402, AES-256, Camera housing shall be IK10, IP66, rated. ONVIF profiles S, G and T supported. Power supply: 12VDC/24VAC/PoE. Operating range: -10°C to plus 60°C, 1- 95% RH. Certifications: BIS, CE, FCC Part-15 (Class A), ONVIF S, G, T, IP67, IK10, with mandatory STQC certification available on day of release of RFP. Makes Honeywell /CPPLUS/Matrix (DSR 40.4.2)
SITC of 16 Channel Network Video Recorder. Operating System Embedded LINUX. Video Output 2 HDMI (4K), 2 VGA. Camera supported Resolution Supports up to 12MP: 8MP: 5MP: 4MP: 3MP: 2MP Resolutions. Video Compression H.265/ H.264. Channel 16 channels. Incoming and Outgoing Bandwidth 380Mbps or better. Motion Detection supports. Playback Capability 4-channel 16 MP@25 fps: 8 channels 8MP@25fps: 12 channels 5MP@25fps: 16 channels 4MP@25fps, 32 channels 2MP@25fps. Certifications BIS, UL, CE, FCC, RoHS, ISO 9001, CMMI Level 3 and Level 5, ISO/IEC 27032, GDPR Makes Honeywell /CP-PLUS/Matrix (DSR 40.10.2)
SITC ofLayer-2 switch 24 x 10/100/1000 Base-T ports and additional 4 nos. SFP ports. Switch should supported for load balancing and constructing scalable LANs. IPv6 routing (OSPFv3) is supported in hardware for maximum performance.Switch should have 370 watt power budget. Switch support Auto-voice VLAN, SNMP v1, v2c, v3, RFC 1643 Ethernet Interface MIB, RFC1493 Bridge MIB, Jumbo Frame Support (up to 9 KB), IEEE 802.1Q Tag VLAN, IEEE 802.1p (Class of Service), 128 Static VLANs , , DSCP - L3 QoS, Port -based ingress/egress rate limiting, Forwarding modes: Store-and-forward, Bandwidth:52 Gbps.IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3x full-duplex flow control, IEEE 802.1D Spanning Tree Protocol, IEEE 802.1S Multiple Spanning Tree Protocol, IEEE 802.1S Multiple Spanning Tree Protoco Make: Cisco/Juniper/Zyxel/Extreme (DSR 39.3.1)
SITC of 4TB Capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. Make Seagate/WD/Toshiba (DSR 40.12.1)
SITC of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf,Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated Make (RandM/D-link/Molex) (HSR 39.11)
SITC of CAT6 UTP 24 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m onforming to the following standards like EN 50173, ISO/IEC 60603-7 and 11801/IEC 60332-1, UL VW-1 Make (RandM/Dlink/Molex) (DSR 39.12.1)
SITC of 43` LED Monitor, Full HD, HDMI Port, Component Video Inputs, 1 Digital Audio Out, Make: LG/Panasonic/Samsung (DSR 42.4.2)
SITC of 3core 1.5sqmm power cable. Make: Havells, Polycab, Finolex (DSR 20.28.1)
Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)`s both for the rectifier and inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be )95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be ( 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz plus /- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 and 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 3KVA MAKE APC/ LIBERT EINOVA/Microtek/Emerson (DSR 26.1.2)
SITC of 6 U rack with cable manager,fan tray,power distribution kit complete in all respect.Make: Comrack/Vallrack/Netrack (DSR 39.23.1)
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel . of required loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. The panel should also have IP30 or better protection. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make: Morley ZX5SE,Bosch Avenar 2000, Siemens Cereberus EN. (DSR 28.2.1.2)
SITC of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 1 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Morley HM/PTSE/I plus MI/B501AP/IV ,Bosch FAP425-OT plus MS400B,Siemens OH720 plus DB722 (DSR 28.2.4)
SITC of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 1 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector). (Make: Morley HM/RHSE/I plus MI/B501AP/IV, Bosch FAH-425-T plus MS400B, Siemens HI720 plus DB722). (DSR 28.2.9)
Supply, installation, testing and commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass, Bosch FMC-210- DM-G-R, Siemens FDM221. (DSR 28.2.14)
Supply, installation, testing and commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make : Morley MI/DCMO,Bosch FLM-420-RLV1-E, Siemens FDCIO222
Supply, installation, testing and commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make : (Morley MI DMMI, Bosch FLM-420-O1I1- E,Siemens FDCIO223
Supply, installation, testing and commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05,Bosch FNM-420, Siemens FDS224R (DSR 28.2.15)
Supply Installation, Testing and Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Pearl/Giolite/OMEX
SITC of minimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj
SITC of 3 KVA Online UPS Overvoltage cut-off device Support for up to external battery cabinets, Generator Compatible with Wide Input. Wide Input Voltage window for Indian Environmental Condition andfor Optimized BatteryPerformance. 30 minutes back up MAKE APC/ Elnova/Microtek/Emerson (DSR 26.1.2)
SITC of 240 Watts Mixer amplifier, Inbuilt Bluetooth for audio streaming, Supports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, Insert feature to use as a pre/power amplifier , Optional 2 tone chime generation for input 1, Frequency response -80 Hz to 18 kHz ( plus 1/ 3 dB @ 10 dB ref. rated output), Distortion- (1% @ rated output power, 1 kHz, Bass Control - Max. ± 8 dB , Treble Control - Max. ± 8 dB ,Connector - Cinch, stereo converted to mono, Sensitivity - 200 mV to 300 mV, Impedance - 22 kohm, S/N (flat at max. volume) - =70 dB, Headroom -)25 dB complete in all respect Make /BOSCH/ Siemens/Honeywell (DSR 28.3.7)
Supply, installation, testing and commissioning of 15U Standard rack to place all Av equipment Make Valrack, Comrack,Hive Networks. (DSR 39.23.3)
Supply and erection of FIRE EXTINGUISHERS dulyhang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire) ABC Dry power type fire Extinguishers of 5 kg. capacity
Supply and erection of FIRE EXTINGUISHERS dulyhang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire) Co2 type fireextinguishers of 4 Kg capacity
Wiring for PA system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Plaza. 2 x 1.5 sq.mm (DSR 28.5.3.1).
Suply and erection of PVC copper insulated and sheathed FRLS 1-core circular flexible wire Make: Plaza / Havells / Polycab / R.R. Kabel / KEI (Size 1.50 sqmm ( 1/1.40 mm).
SITC of Cabinet and Ceiling Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V, ABS Rated impedance - 1667 Make /BOSCH/ Siemens/Honeywell (DSR 28.3.4)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
BOQ_574887.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid