COL NK SAH
CWE AF Lohegaon pune 411032
REPAIR AND MAINTAINANCE OF COOLING APPLIANCES SPLIT/WINDOW AC WATER COOLER, REFRIGERATOR DEFRIZER DESERT COOLER VOLTAGE STABLIZER AND IMSC ITEMS AT 2 WING AF STN PUNE UNDER GE AF LOHEGAON
2019_MES_294262_1
81777/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF LOHEGAON
As per NIT and tender document
5 documents required · 5 mandatory
₹500
GE AF Lohegaon
₹40,000
Yes
18 Mar 2020
1 Nov 2019
5 Dec 2019
2 Nov 2019
3 Dec 2019
16 Nov 2019
Amount
M&L for Servicing, cleaning of complete unit (indoor and out door) of air cooled split type AC of any capacity by using blower, cleaning of condenser coil with water, checking all the parts, electrical connection , cleaning the air filters, combing of fins by using fins comb including replacing defective filters, burnt wiring, tightening of electric wiring connections, etc, complete all as specified and directed by Engr in Charge
M&L for replacement of existing old U/S insulation of refrigerant pipes of spit air conditioner up to 3 TR cap complete all as specified and directed by Engr in Charge
M&L for replacement of micro processor printed circuit board complete suitable for split type AC's as per exiting make & model up to 3 TR Cap complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv PCB of indoor/outdoor unit of Inverter type AC as per existing make & model complete all as specified and directed by Engr in Charge
M&L taking out defective micro processor printed circuit board of split type AC of existing Make/Model up to 3 TR Capacity for repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable starting capacitor suitable of window type/split type AC's up to 3 TR Capacity as per existing cap complete all as specified and directed by Engr in Charge
M&L for replacement of unserviceable running capacitor 30/36/40/55 mfd suitable for split/window type AC's 1 to 3 TR cap of existing make & model complete all as specified and directed by Engr-in-charge.
M&L for replacement of capacitor 4/6 mfd suitable for fan motor of (split/window /water cooler/Desert cooler fan motor) complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable swinging motor of indoor unit of split type AC up to 3TR capacity suitable for existing make/model complete all as specified and directed by Engr in charge
M& L for replacement of condenser fan/blower motor with bush and washers as per existing make and model for split type AC up to 3 TR Capacity complete all as specified and directed by Engr-in-charge.
M&L for replacement of existing unsv compressor unit with unit with new Compressor unit as per existing make & model including taking out the old u/s burnt out Compressor of split type Air Conditioner, unsv replacement of bushes, sleeves, washers nut and bolt, relay terminal cover, clips reqd for fixing of new compressor, cutting, brazing of copper piping, charging of suitable refrigerant gas as required Qty to obtained desired cooling, carry out leak test etc., all as required at site complete for following capacity:- complete all as specified and directed by Engr-in-charge. Make: Emerson/Carrier/ Tecumsha/ LG/Voltas
Capacity 1.5 TR
Capacity 2.0 TR
Capacity 3.0 TR
M&L for replacement of unserviceable fan blade of condenser unit of split type AC up to 3 TR as per existing make and model complete all as specified and directed by Engr-in-charge.
M&L for leak detection by nitrogen pressure test in refrigerant system of AC, cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity to achieve desire coolingcomplete all as specified and directed by Engr-in-charge.
Split type AC 1.5 TR capacity
Split type AC 2.0 TR Capacity
Split type AC 3.0 TR capacity
M&L for replacement of unsv contactor kit of split type AC as per existing make & model up to 3 TR complete all as specified and directed by Engr-in-charge.
ML for replacement of unsv copper tubing 5/8" dia complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv copper tubing 3/8" dia complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv power cable cord PVC flexible copper wire 2.5 sqmm 3 core complete all as specified and directed by Engr-in-charge.
Labour only for rectification of water leakage problem by cleaning indoor unit & drain pipe of split type AC up to 3 Ton cap complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv valve of split type AC up to 3 TR cap complete all as specified and directed by Engr-in-charge.
M& L for replacement of unserviceable hermetically sealed compressor with new Compressor suitable for window type AC of following capacity, including replacement of unserviceable bushes, sleeves, washers nut and bolt ,foundation legs including relay terminal cover and clips and including cutting, brazing, leak detection, charging of suitable refrigerant gas as required to obtained desired cooling, carry out leak test etc., all as required at site complete commissioning, testing for the following capacity complete all as specified and directed by Engr-in-charge. Make-Emerson/Carrier/ Tecumsha/ LG/Voltas
Compressor suitable for 1.5 TR Capacity
Compressor suitable for 2.0 TR capacity
M&L for replacement of unserviceable electric blower motor suitable for 1/1.5 /2TR capacity window type AC double speed, single phase 230 volt 50 Hz, complete all as specified and directed by Engr-in-charge. Make - Gulmarg/AUE or as per existing make/ type.
M&L for replacement of unserviceable thermostat switch suitable for water coolers, Window type AC's /split AC's, refrigerators and Deep freezers any capacity, make & model complete all as specified and directed by Engr-in-charge.
M&L for replacement of starting relay suitable for water coolers, Window type AC's /split AC's, refrigerators and Deep freezers any capacity, make & model complete all as specified and directed by Engr-in-charge.
M&L for replacement of existing unsv fan motor of desert coolers up to 6000CFM as per existing model & speed including taking out the old /unserviceable motor complete all as specified and directed by Engr-in-charge.
M&L for replacement unenviable water pump of desert cooler with submersible type water pump 0.6 KW, 1.25 m head pump complete all as specified and directed by Engr-in-charge.
M&L for replacement of Khas pad (set of three) with best quality new pad, for desert coolers of 4000/5000 cfm capacity.complete all as specified and directed by Engr-in-charge.
M&L for replacement of fan speed control switch of Desert cooler up to 6000 CFM PVC body unit as per existing make & model complete all as specified and directed by Engr-in-charge.
M&L for replacement of Lover control knob switch of Desert cooler up to 6000 CFM PVC body unit as per existing make & model complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv fan blade of desert cooler up to 6000CFM as per existing type make & model complete all as specified and directed by Engr-in-charge.
M&L for replacement of honeycomb pads of desert cooler up to 6000CFM as per existing size complete all as reqd at site complete all as specified and directed by Engr-in-charge.
M&L for servicing of water cooler of installed capacity 40/40 to 150/150 Ltrs, cleaning the tank, condenser coil, oiling the fan motor, checking all parts, repair to electrical burnt/loose connection, replacement of rubber gasket, washer minor u/s parts etc. complete all as specified and directed by Engr-in-charge.
Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for water coolers of following capacities including provn of bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity:- Emerson/Carrier/ Tecumsha/ LG/Voltas complete all as specified and directed by Engr-in-charge.
Cooling capacity 40 Ltrs/Hr
Cooling capacity 60 Ltrs/Hr
Cooling capacity 150 Ltrs/Hr
M&L for leak detection in refrigerant system of water cooler (40/60/80/120/150 Ltrs cap) including cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity complete all as specified and directed by Engr-in-charge.
S&F push cock of 15 mm dia for water cooler and taking out the unserviceable push cock and complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv float valve for water cooler (40/60/120/150 Ltrs) capacity any as per existing size and type complete all as specified and directed by Engr-in-charge.
Servicing of air curtains, single phase, 240V by checking all electrical connection, blower, motor oiling greasing and replacement of u/s wire, lugs, bushes, rubber pads, bearing etc. complete all as specified and directed by Engr-in-charge.
Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for refrigerators including provn of bushes, sleeves, washers nut and bolt for 4/3 Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging suitable refrigerant and commissioning testing for the following capacity. Make Emerson/Carrier/ Tecumsha/ LG/Voltas complete all as specified and directed by Engr-in-charge.
165 - 200 Ltrs capacity
285 - 300 Ltrs capacity
M&L for leak detection in refrigerant system of Refrigerator (165 to 300 Ltrs cap) including cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity complete all as specified and directed-
Taking out existing split type air conditioners of any type and capacity removing from the site and keeping it in a safe custody for re-use or deposit in store complete all as specified and directed by Engr-in-charge.
Fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through stone masonry wall with connected accessories such as bracket, copper tubing, cable from indoor to out door unit and rain water pipe etc as per site requirement complete all as specified and directed by Engr-in-charge.
M&L for replacement of old unsv outdoor unit of split type with AC 3 star rating, 1.5 TR Cap having copper tubing, high EER rating compressor (for gas R-407/410/32), blower motor etc. complete including, making elect, refrigerant piping connection, brazing, leak testing and charging suitable refrigerant gas to achieve desired cooling effect and testing complete all as specified and directed by Engr-in-charge. Make- Blue Star/Voltas/Hitchin/Daiken
Servicing of ceiling suspended DX type AHU of VRF system by checking all parts, repair to electrical connection, cleaning of air filter, cooling coil, fan/blower and replacing minor u/s parts like bushes, nut bolts including taking down air diffuser grill from fall ceiling, cleaning and refixing of the same as directed by Engr-in-charge.
M&L for replacement of Unsv indoor unit of split type AC 1.5 TR complete having 3 star rating suitable for (R-407/410/32) gas complete all as specified and directed by Engr-in-charge. Make- Voltas/Blue Star/Hitachi/Daiken
M&L for replacement of unsv MCB SP C series 20 A to 32 A m breaking cap 6kA complete all as specified and directed by Engr-in-charge. Make - L&T/Legrand/Hager/Siemens
M&L for replacement of Metal plug 20A, 2Pin+SC complete all as specified and directed by Engr-in-charge. Make L&T/Legrand/Hager/Siemens
M&L for replacement of Metal socket 20A, 2 pin+SC complete all as specified and directed by Engr-in-charge. Make L&T/Legrand/Hager/Siemens
M&L for replacement of Unsv sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole C series MCB 20 Amps, 240 volts complete all as specified and directed by Engr-in-charge. Make: L&T/Legrand/Hager/Havel's
M/L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & capping complete all as specified and directed by Engr-in-charge. Note :Two runs of 4.0 Sqmm copper cable, one run of earth wire of 4.0 Sqmm copper cable shall be measured & paid as one length).
Servicing of air shower for 2 persons by checking all electrical connection, replacing u/s wire, lugs, washers, sensors, push button, cleaning filters, blower motor servicing, oiling, replacement of bearing of blower assembly, bush etc complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv Doormat magnetic switch of air shower
M&L for replacement of unsv hydraulic Door closer assembly of air shower complete all as specified and directed by Engr-in-charge.
M&L for repair of Printed circuit board of air shower for 2 persons taking down and re-fixing of the same as complete all as specified and directed by Engr-in-charge.
M&L for servicing, rewinding of stabilizer 4 KVA with copper winding as per existing gauge & turns including replacement of defective items complete all as specified and directed by Engr-in-charge.
M&L for servicing, rewinding of stabilizer 5 KVA with copper winding as per existing gauge & turns including replacement of defective items complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv condenser cooling coils of Split type AC up to 3 TR cap with new copper coil including taking out unsv condenser coil complete all as specified and directed by Engr-in-charge.
M&L for replacement of unsv motor of air curtain as per existing make and model including replacement of bush, baring etc as reqd at site complete all as specified & directed by Engr in Charge
M&L for replacement of unsv drain flexible PVC pipe of split type AC complete all as specified and directed by Engr in Charge
M&L for replacment of unsv HEPA filters having 99.97% DN to 0.3 MIC of Air shower as per existing size complete all as specified and directed by Engr-in-charge.
M&L for replacment of emergency release switch of Air shower including making proper connections complete all as specified and directed by Engr-in-charge.
M&L for replacment of unsv pre filters of Air shower flange type having efficiency 95% DN to 10 MIC as per existing size. complete all as specified and directed by Engr-in-charge.
M/s. NILESH SURESH KAWOOR
somnath engineering corporation
Sahara Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .