| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹67.4 L+₹12.4 L (22.5%)Rejected-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹84.3 L+₹29.3 L (53.2%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹84.6 L+₹29.6 L (53.8%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹99.8 L+₹44.8 L (81.5%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
9 Jul 2020, 6:00 pmClosed
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR TO EXTERNAL PLASTER, RAIN BEATING WALLS CJAJJAS SHAFT SEEPAGE AND CONNECTED WORKS AT RS COLABA AND REPAIR TO WATER PROOFING TREATMENT LEAKAGE SEEPAGE SUNKEN TREATMENT SANITARY FITTINGS CI PVC PIPES AT OLD RS COLABA UNDER AGE BR II NW NAVY N
2020_MES_349334_1
8197/CWE(NW)/MUMBAI
Open Tender
Civil Works
Item Rate
270 days
GE NW Navy Nagar
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE NW NAVY NAGAR
₹1.9 L
Yes
7 Aug 2020
2 Jun 2020
11 Jul 2020
2 Jun 2020
9 Jul 2020
24 Jun 2020
2 Jun 2020 - 23 Jun 2020
Amount
Part I Taking down plaster (Chipping off ) removing ,carefully Loose plaster by low impact Hammer without damaging the structure and cleaning and disposal of debris out side the premises complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for 20 mm thick plastering in two coats 15 mm thick backing coat in CM 1:6 and 5 mm thick setting coat in CM 1:4 mixed with water proofing compound @ 2% by weight of cement on fair faces of brick work or concrete wall surfaces finished even and smooth without using extra cement all as specified including scaffolding, Safety net complete all as specified and directed. (Note :- WPC shall be measured and paid separately)
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L Rendering 10 mm thick in CM 1:3 on ceiling finished even and smooth complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Supply only integral water proofing compound.
M & L f or providing and applying Double Coat Sand Face polymer modified Plaster in patches (25 mm thick min. ) in C.M. ratio 1:4 plaster including Drip mould/ Bands / Pattas etc. complete as per the instructions and as per our standard technical specification manual complete all as specified and directed. (Note :- work will be carred out with scafolding all over bldg upto 14th floor of wall. Rate of scaffolding is included in this item)
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L preparing newly plastered surfaces of walls and applying two coats of Acrylic based exterior paint exterior grade (100% Acrylic) over a coat of primer & bio wash on wall complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for Siliconate Injection Grout for rising dampness .inserting the nozzles for the rising dampness. The spacing of holes will 2 No’s holes in every 1 Sqm, Using 12 mm to 15 mm diameter drill bit, drill holes at an inclination of 45o the extent of ½ to ¾ the wall thickness and injecting in the lowest possible point almost touching the defective damp proofing course (Slab in case of floors in RCC apartments).Depending upon the severity of dampness and the materials used in the wall & in its construction, a hand pump sufficient to create pressure of approx... 2 kg/cm2 must inject chemical through pressure grouting machine. Inject the diluted liquid (1:4) by pumping till the point of return of liquid is felt. Allowing it to remain for sometime before moving to the next nozzle. Observing the area for 24 hrs. Followed by Removal of the extended / protruding nozzles and seal the holes with suitable compound. The treated areas should be washed thoroughly. Followed by providing of protective plastic cloth with plastering finish complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M & L for water proofing treatment of external walls by applying two coats of elastomeric coating material after cleaning the surface thoroughly and sealing all cracks with acrylic sealing compound as per the manufacturer’s specifications and directions of Consultant/Architect. Make : Build core STP chemicals or equivalent complete all as specified and directed. (Note :- work will be carred out with scafolding all over bldg upto 14th floor of wall. Rate of scaffolding & acrylic based exterion paint is included in this item)
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M & L for water proofing treatment of chajja applying two coats of elestomeric coating material after cleaning the surface thoroughly and sealing all cracks with acrylic sealing compound as per the manufacturer’s specifications complete all as specified and directed.Make : Buildcore STP chemicals or equivalent. (Note :- work will be carred out with scafolding all over bldg upto 14th floor of wall. Rate of scaffolding is included in this item)
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Writing letter or figures as per existing name n exc 30 cm high (Block,Roman, Italic or Indian) per cm height of letters complete all as specified and directed.
M&L anodised aluminium sheeting 22 gauge thick fixed in repairs as in crumple section.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Removal of existing water proofing treatment of the roof, cleaning with wire brushes etc including demolition of PCC padding of any description and in any position including shifting or removing of demolished material from roof slab to ground/land including all arrangement complete all as specified and directed.
M & L for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) average thickness n.exc 50mm, mixed with Shali Plast LW+ of STP/Pidilite URP of Dr. Fixit or Equivalent and appoved as per manufactures instruction. Before laying concrete surface shall be cleaned and a bond coat of slurry with Shali Crete URP (of STP) or quivalent with cement to be applied. Alll cracks in slab to be openend in 'V' groove and filled with Shali Fix RMC a Polymer Morter of STP/ equivalent complete all as specified and directed.
M&L for 20mm thick rendering in CM 1:4 with the addition of Shaliplast LW+ @ 200ml per bag of cement on fair faces of brick or concrete surfaces complete all as specified and directed.
M&L for protecting the roof including parapet wall with water proofing coating complete all as specified and directed. (a) Clean the surface and apply one coat of primer (STP Shali Urethane BTD diluted in water in 1:1 ratio and applied @ 400 gm/sqm OR Dr, Fixit primeseal diluted in water in 2:1 ratio and applied @ 7-8 sqm/ltr) and allows to dry for 6 to 8 hrs. (b) Apply first coat of water proofing coating over primer surface (Shali Urethene BTD with non butuminous bleding of STP Ltd. @ 1 Sqm/Ltr without dilution OR Dr. Fixit New Coat without any dilution @ 2 Sqm /Ltr) (c) Lay Non woven fiber glass mesh (Reinforcement of Shali Geo Text 40/50 gsm of size 2.5mm x 2.5mm) or equivalent with overlap of 50 mm on both direction while the first coat is still wet. (d) Apply second coat of water proofing coating as per manufactures instruction after 6-8 hrs of drying of first coat. (e) Apply third coat of water proofing coating (as per manucturer instruction) after 6-8 hrs of drying of second coat The total thickness of 1 to 1.2mm must be achieved after 7 days of air cure. Note : 1) The colour of each coat shall be as directed by GE. 2) The work shall be carried out by authorised applicator only 3) Water proofing to rain water spouts to be done as per manufacturer instruction
M & L for applying APP (Atactic poly propylene) bitumen membrane 4mm thick APP modified weight not less than 3.5 Kg/Sqm reinforced with non woven polyester fibre of weight 160 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene, applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer 0.25Kg/Sqm over roof ( An overlap of 100mm & 150mm shall be provided on sides and ends respectively ) all as per manufacturers instructions and complete all as specified and directed. .
Cutting grooves 75mm wide & 65 mm deep in brick wall / RCC surfaces at any location shaping horizontal face with mechanical cutter and grooves filled with PCC 1:2:4 type B-0 (using 12.4mm graded stone aggregate) mixed with chemical compound SUPER LATEX OR DR FIXIT OF PIDILITE INDUSTRIES LTD or SBR LATEX of STP LTD mixed with proportion 200 ml per 50 Kgs cement as per manufacturers instructioncomplete all as specified and directed.
M&L for -cement concrete tiles 200mmx200mmx20mm thick, machine pressed; set, jointed in neat cement slurry with grey cement and no pigment & pointed with epoxy mortar of width 3 mm joint in floors, and cut & polished over 10mm thick cement screed bed in CM 1:3 complete all as specified and directed.
Water proofing treatment to rain water spouts of entire roof terrace by opening of all the existing Failed loose pipes and its Joint (In Old Structure), replacing the same by an appropriate dia pipe( not less then110mm) followed by Application of two coats of cold modified bituminous ensure leakage free joint.(work includes filling of mortar and making good the same) complete all as specified and directed.
M & L for Sand Face polymer modified Plaster in patches (25 mm thick) in C.M. ratio 1:4 in two coats, backing coat 15 mm thick over 10 mm thick finishing coat plaster including Drip mould/ Bands / Pattas etc. (parapet wall) complete as per the instructions and as per our standard technical specification manual complete all as specified and directed
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of bricks work or concrete finished even and smooth without using extra cement omplete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for 05 mm thick plastering in CM 1:3 on concrete surface on ceiling finished even and smooth omplete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
All as per item 67 above but on ceiling.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for Preparation of old painted surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for Preparation of old painted surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of antirush paint/red oxide primer complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Demolition of lime/cement concrete of any description and in any position not otherwise specifically provided for including chaina mozaic, WC complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Roughening surfaces of old concete floor/ wall by picking, sweeping clean & washing down with water to remove dust etc, treating cement concrete or concrete surfaces with three dressing of sodium silicate & brushing with neat cement slurry with 3.00 kg of cement per sqm and applying cement plaster 10 mm thick in CM 1:3 with WPC & applying evenly a tack coat of bitumen 85/25 at 1.2 kg/Sqm complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Plain cement concrete 1:7:12 type F2 (using 40mm graded stone aggregate) in sunken floor, 150mm thick, surface finished fair and even complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Dismantling floor, hearth, or wall tiling incl cement mortar4 bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L non-skid coloured Ceramic tiles 300x300x6 to 7mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not excceding 0.11 sqm, in floors etc, set and jointed in epoxy mortar and pointed in white of coloured cement to match including 20 mm thick screed bed in CM 1:6 complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M & L Coloured glazed ceramic tiles 300 x 200 x 7mm on vertical surfaces set & jointed in neat cement slurry and pointed in white cement mixed with pigment complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for rendering 10mm thick in cement mortar 1:4 on backing coat of wall tiles etc complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F in repairs for vitreous china squatting pan Orissa pattern of size 580 x 440 mm white with back inlet and integral footrest and anti syphonnage pipe including 'P' or 'S' trap and provn of lime concrete complete all as specified supplied and fixed in repairs.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F in repairs vitreous china, semi-pedestal pattern ( Anglo- Indian type), white (excluding fixing bolts flushing cistern and including flush pipe) including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F in repair Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F in repair 32mm dia waste coupling of PTMT (half or full threaded) minimum weight 32mm- 45gns complete all as specified and directed. (Make:- Blue star/Nirali)
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F pillar tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F 32mm dia High density polyethylene (LDPE) pipes of pressure 6 kgf/sq.cm for WHB in repairs includding socket & screw complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F Unplasticised PVC pipes of pressure rating 6 kgf/Sq.cm of 50 mm bore fixed complete to walls, ceiling or in floors including bend and sockets etc; any type of pipe complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F in repair PVC valveless, syphonic action type, flushing cristern, 10 ltr capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F Flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for CI Nahani trap dia of outlet 75mm fixed in repairs including jointing to waste pipe in runlead fixed in cement concrete type B 1 (1:2:4) complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for CI floor trap dia of outlet 100mm fixed in repairs including jointing to waste pipe in runlead fixed in cement concrete type B 1 (1:2:4) complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F PTMT grating doom over Nahani trap and floor trap of 100mm Dia (Minimum weight 25 gms) complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Taking down CI soil/waste/vent/rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F CI soil/waste/vent pipe in any length with ears 100mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
All as per item 192 above but except pipe.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F CI soil/waste/vent pipe in any length with ears 75mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
All as per item 202 above but except pipe.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F CI bends (any radius) for soil/waste pipes 100mm bore diminishing pieces or tapers on walls complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F CI bends (any radius) for soil/waste pipes 75mm bore diminishing pieces or tapers on walls complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F CI branch piececs single (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches for 100mm bore pipe (Y or T) complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F CI branch piececs single (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches for 75mm bore pipe (Y or T) complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F 100mm cast iron sanitary connection socket to fit WC out-let complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Taking down PVC rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F PVC (SWR) pipes 150mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F PVC (SWR) bends 150mm bore any radius
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Taking up or down GI tubing and connections 15 mm bore including cleaning for refixing or removal to store complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Refixing old GI tubing and connection15 mm bore in new or old position in ( Walls, ceiling, floors etc) with old accesories complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F GI Tubing 15 mm bore medium grade with all fitting and fixed comlete to wall and ceiling or laid in floors complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F Bib tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F Stop valves 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S & F swivel shower of PTMT any colour for fixing with 15mm pipe (Min weight 40 gms)
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L for taking out/removing vegitation growth or shrubs and injecting chemical GLYPHOSPHATE 41% SL 20 ML or till refusal by making cut/injection in the stem of plants 30 mm c/c and spraying with solution (25 ml GLYPHOSPHATE 41% diluted with one lit of water) and removing the plants/vegitation growth completely dead, including necessary scaffolding, julas etc complete as per manufacturer of chemical Biostadtlndia Ltd or equivelent approved by GE.
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M&L preparation of old decorated surfaces of wall including washing and applying two coat of Acrylic emulsion paint exterior grade (100% Acrylic) over one coat of primer incl necessary scaffolding, Safety net complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Cleaning & drying surface of floor /dado of bathroom, WC & kitchen etc by mechanical means i.e. blower complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Opening joints of floor tiles, junction of floor & dado tiles, 300mm height from bottom layer of dado tiles with electrical grinder, electrical blower etc complete in WC, bathroom & kitchen complete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
M & L for inserting chemical mixture of polymer 960 & o.p.c. through these opened joints manually by trowel to seal all cracks honey combing of slab/beams and walls etc complete upto 300mm height from bottom layer of dado in WC, bathroom & kitchen including NTcomplete all as specified and directed
(a) Height upto and including 4th floor.
(b) 5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Removing demolished material exceeding 5KM, but not exceeding 15KM outside MD land complete all as specified and directed (Note:- For item No 1 to 307 Work to be carried out at G+14 bldg including top roof,parapet and shaft walls with scaffolding & safety measures in repairs and in patches).
RAMESH ENTERPRISES
Darpan Construction
SHREE JAGDISH FURNITURE CO.
7hills Construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .