GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
MAINT REPAIR WORK OF SWIMMING POOLS IN THE AREA OF AGE U WATER SUPPLY II UNDER GE U WATER SUPPLY DELHI CANTT 10
2021_MES_423266_1
GE/WS/D-160 of 2020-21
Open Tender
Civil Works
Item Rate
220 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹20,000
Yes
12 Aug 2021
18 Feb 2021
18 Mar 2021
18 Feb 2021
16 Mar 2021
4 Mar 2021
Amount
Cleaning of TOI Swimming Pool of size 25 m x 13.5 m using acid and other suitable methods before filling, as required at site complete all as specified and as directed.
Cleaning of NOM Swimming Pool of size 25 m x 13.5 m using acid and other suitable methods before filling, as required at site complete all as specified and as directed.
Cleaning of RRRC Swimming Pool of size 25 m x 13.5 m using acid and other suitable methods before filling, as required at site complete all as specified and as directed.
Cleaning of DID Swimming Pool of size 50 m x 21 m using acid and other suitable methods before filling, as required at site complete all as specified and as directed .
Cleaning of Harbux stadium Swimming Pool of size 50 m x 21m,using acid and other suitable methods before filling, as required at site complete all as specified and as directed.
Cleaning of Harbux stadium Diving pool of size 16 m x 16 m,using acid and other suitable methods before filling, as required at site complete all as specified and as directed.
Cleaning of Harbux stadium Baby pool of size 6 m x 4 m ,using acid and other suitable methods before filling, as required at site complete all as specified and as directed . Note for srl item Nos 01 to 07 :- Quoted rates shall include for man power required for filling the swimming pools with water and de-watering on completion of operation and maintenance of swimming pools.
Supply & fixing in replacement Butterfly valve of size 100 mm dia including with & including jointing material complete all as specified and as directed.
Supply & fixing in replacement Butterfly valve of size 150 mm dia including with & including jointing material complete all as specified and as directed.
Supply, fixing, jointing and testing in replacement of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 of size 100mm dia complete including taking out unsv NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item
Supply, fixing, jointing & testing in replacement of Cast Iron Sluice Valve of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
100 mm bore
150 mm bore
Taking down/out including opening of pumping set of capacity upto 05 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of coupling & renewal of warnout bearing with & including suitable nuts,bolts & washers etc and other repairs of minor nature , applying two coats of synthetic enamel paint over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed.
Taking down/out including opening of pumping set of capacity 7.5 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of coupling & renewal of warnout bearing with & including suitable nuts,bolts & washers etc and other repairs of minor nature , applying two coats of synthetic enamel paint over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed.
Taking down/out including opening of pumping set of capacity 7.5 HP to 15 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of rubber coupling with & including suitable nuts,bolts & washers etc and other repairs of minor nature , applying two coats of synthetic enamel paint over a coat of red oxide primerchecking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed.
Taking down/out including opening of pumping set of capacity 15 HP to 30 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of rubber coupling with & including suitable nuts,bolts & washers etc and other repairs of minor nature , applying two coats of synthetic enamel paint over a coat of red oxide primer,checking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed.
Taking down/out including opening of Compressor at site, carrying out the servicing, greasing, oiling, gland filling, replacement of rubber coupling with & including suitable nuts,bolts & washers etc and other repairs of minor nature , applying two coats of synthetic enamel paint over a coat of red oxide primer checking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 100 Amps with breaking capcity 16 KA , 415 volts complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 160 Amps with breaking capcity 25 KA , 415 volts complete all as specified and as directed.
Supply of GI pipe medium grade of size 50mm bore ISI marked.
Material & labour for welding and fixing of 25 to 50mm dia GI pipe Heavy grade, length more than 5 mtr for opening and closing for valves with a help of circular wheel, inside a reservior/sump for pool operation complete all as specified and as directed
Material and labour for painting on steel and iron surfaces with two coat of synthetic enamel paint as per existing colour scheme or pattern after preperation of old painted surface of any description over 10cm in width or girth complete all as specified and directed
Supply and fixing in replacement copper cable of size 2.5 sqmm 3 core, 1100 volts complete all as specified and as directed
Supply and fixing in replacement PVC water suction hose pipe 2 Inch(50mm) and 50 feet long complete all as specified and as directed
Supply in replacement 17.5 Inch Aluminium weighted swimming pool vaccum head on wheels, all type of pool floor cleaner, Suction sweeper complete all as specified and as directed
Material and labour Rewinding of ceiling fan with suitable gauge of enamelled copper wire complete and including with suitable class of insulating varnish including winding materials, attending lathe work to fan rotor shaft and including painting of ceiling fan with two coats of synthetic enamel paint and writing MES numbers complete all as specified and as directed
All as per item No. 13 here-in-before but for exhaust fan of size 300 mm
Testing of Swimming pool in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 3328 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification Note :- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source swimming pool.
Taking down the Direct on line starter for 7.5 Hp motor relay range 20-32 and replacement with new DOL starter 7.5 Hp relay range 20-32 in existing starter panel complete all as specified and directed
Taking down the unserviceable FASD ML 1.5 (with MU relay) of any size and replacement with new FASD ML 1.5 (with MU relay) 25 HP including stainless steel box existing starter panel complete all as specified and directed
Supply and laying rubber mat of dimensions 2mtrX1mtrX10 mm as per ISI mark for 11 KV
Supply, installing, testing and commissioning in replacement of factory made and tested LT Electrical panel CPRI approved make Indoor type suitable for 415 Volts, 3 phase, 4wire 50 Hz AC supply system – Seven tank process, powder coated, having front and back door, bus bar chambers, cable galleries compartmentalized for each out going, made out of CRCA Sheet 3.15 mm thick, indoor type, Degree of Protection – IP 54, Cable entry – Bottom, incomer – 1 No. Incomer shall consist of following components – LED Type Indicator (1) Incoming MCCB 200 A 25 KA 4 Pole Thermal Magnetic- 1 Nos (2) Digital volt meter (0-500 V) with VSS - 1Nos (3) Digital Amp meter (0-200A) with ASS -1Nos (4) Control MCB SP 6 A - 3Nos (5) C.T 200/5 A Tape Wound - 3Nos (6) Indicating light Red/Yellow/Green -3Nos (7) Star Delta Starter 25 H.P- 5Nos (Each having following Items) (a)Outgoing MCB 63 A 10 KA 3 Pole 'C' Series -1Nos (b) Power contactor 32 A 3 Pole -2Nos (c) Power contactor 25 A 3 Pole 1Nos (d) BI Metal over load relay 14-23 A -1Nos (e) Star Delta Timer Micon 225 -1Nos (f) Single Phase Preventer -1Nos (g) Push button with block Start/Stop -2Nos (h) Indicating light On/Off/Trip -3Nos (j) Terminal Block 3 Way -2Nos (8) Motor protection automatic phase sequence corrector universal make single phase preventer with facility to change over from automatic to manual with over load proctection for contactors upto 160 Amps -1Set (9) Bus Bar Chamber 300 A 4 strips Aluminium -1Set (10) Enclosure of suitable size -1No (Universal Switch gear control)
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I complete all as specified and as directed .
Main earthing strip from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .
On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
Taking down old unserviceable point wiring from existing conduit ( light fan , socket or powder) complete such as switches, ceiling rose, pendent holder and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc complete all as specified and directed.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box (Make : Schneider Elect/Legrand Mosaic/Anchor Ave) of suitable size for fixing modular switches/sockets/fan regulator etc complete all as directed for the following :- (Note : The cost of modular type Metal boxes and modular accessories like cover plates will be included in quoted rate.)
one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push.
one socket outet point 5 amps on the same board.
one socket outet point 5 amps on the independent board.
All as per item no. 35 here in before but One 3 pin socket outlet. 15 amps, independent with 4 sq mm copper FRLS wire with 4 Sqmm FRLS copper earth wire
Supply & fixing in replacement of switch piano, flosh type single pole 1 way, 5 Amps complete all as specified and directed.
Supply & fixing in replacement of switch piano, flosh type single pole 1 way, 15 Amps complete all as specified and directed.
Supply & fixing in replacement of socket outlet 6 Amp, 2 in 1,3 pin 5 Amps complete all as specified and directed.
Supply & fixing in replacement of socket outlet 15 Amp, 2 in 1,3 pin 5 and 15 Amps complete all as specified and directed.
Supply & fixing in replacement of Fan regulator step type, 120 watts complete all as specified and directed.
Supply and fixing in replacement of Ceiling rose, surface bakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thick bakelite, laminated hylem sheet of appropriate size & MS box of suitable size complete all as specified and directed.
Supply and fixing in replacement of MCB C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 6 to 32 Amps.
All as item no 16 here in before but of 40 to 63 amps capacity.
Supply and fixing in replacement of basic all purpose sueface and wall mounted LED batten with polycarbonate housing & intigrated electronic driver 1 x 18 Watt incl 1x18 Watt LED with product description 18W830 code LHXEBQP5IN1W018
Supply and fixing in replacement of exhaust fan 450 mm sweep SP 230V , 50Hz,1400 RPM heavy duty including louvre and making hole on wall and grouting the same complete all as specified and directed.
S & F in replacement of street light energy saving envoirmental friendly long life LED street light/Bldg security light made of pressure die cast aluminium housing with with high power LED 60 Watt as light source product description 60W5700K with WSPD code LHETBXU7PA7B060 IP 66
S & F only LED bulb of 7/9 watt
Taking down unsserviceable street light fitting 45W/60W any make and replacement with new driver/LED lamp existing suitable make and model make it funcional complete all as specified and directed
S & F in replacement of LED Uniflood with driver inside PDC housing light white, 70 Watts, 240 Volts Elegant and power saving.
An amount of Rs 9561.00 shall be deducted from BOQ on account of schedule of credit
DHAIRYAE ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .