Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAdmitted-Finance GURGAON | GURUGRAM | HARYANA | 122001 | ₹2.1 L | L1 | Admitted-Finance |
| 2 | L2₹2.3 LAdmitted-Finance | ₹2.3 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Globe Tech Solutions Consultancy Pvt Ltd L1 | DBS ENGINEERS PVT LTD L2 |
|---|---|---|---|---|---|
| 1.00Carrying out GPS Survey, Feasibility study, providing technical consultancy & giving best options for feasible arrangements/layouts with the need of future requirements and existing and detailed modified Electrical Drawings of 132 kV switchyard at 132 kV Asha Substation, showing proposed shifting of existing bays, if required & extension for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV spare feeder bay(s) if feasible, along with shifting/ modification as needed to accommodate required installations on as is where is basis for illustration of S/s Steel Structures, T/Fs, Equipment, Bus-Bars etc. along with marking the boundaries & General arrangement of all switchyard Structures, Equipment, Installations, Bus-Bars/ Bays of all voltage levels along with all the empty Spaces/ Land in the Switchyard & adjoining area under UPPTCL after necessary Survey at site. . Brief description of work is as follows- | |||||
| 2.00 | 132KV Switchyard extension for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV feeder bays (if feasible) along with shifting/ modification as needed to accommodate required installations on as is where is basis with single main and transfer scheme at 132KV Voltage level. The designs of extensions/modifications shall follow/ conform to the existing practices being adhered in UPPTCL / existing structure designs already approved by the design wing of UPPTCL.The detailed drawings including necessary required revisions shall be submitted in three sets of hard copies on A-1 size sheets and one set of soft copy in PDF format for 132/33 kV system. | 1 | Job | 1,15,500 ₹1.2 L | 1,32,000 ₹1.3 L |
| 3.00 | Preparation and submission of Electrical Layout Drawing of existing network and Proposed extensions for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV feeder bays (if feasible) along with shifting/ modification as needed to accommodate required installations on as is where is basis. The ELD will incorporate type of Structures, Equipment names, Interconnections, Measurements etc. along with all installations like O/H & U/G lines and EHV columns/towers.The detailed drawings including necessary required revisions shall be submitted in three sets of hard copies on A-1 size sheets and one set of soft copy in PDF format for 132/33 kV system. | 1 | Job | 79,700 ₹79,700 | 85,000 ₹85,000 |
| 4.00 | Preparation and submission of Single Line Diagram & Sectional Drawings of existing network and Proposed extension for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV feeder bays (if feasible). | 1 | Job | 16,000 ₹16,000 | 16,500 ₹16,500 |
Tender Value
Refer Docs
EMD Value
₹2,500
Closing Date
16 Mar 2026, 6:00 pmClosed
SE ETC Shahjahanpur
Electy Trans Circle Shahjahanpur
Work
2026_UPTCL_1107582_3
Short Term E. Tender no. 66ETC(S)/2025-26
Open Tender
Electrical Works
60 days
Hardoi
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹2,500
4 Apr 2026
11 Mar 2026
17 Mar 2026
11 Mar 2026
16 Mar 2026
11 Mar 2026
11 Mar 2026 - 16 Mar 2026
Carrying out GPS Survey, Feasibility study, providing technical consultancy & giving best options for feasible arrangements/layouts with the need of future requirements and existing and detailed modified Electrical Drawings of 132 kV switchyard at 132 kV Asha Substation, showing proposed shifting of existing bays, if required & extension for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV spare feeder bay(s) if feasible, along with shifting/ modification as needed to accommodate required installations on as is where is basis for illustration of S/s Steel Structures, T/Fs, Equipment, Bus-Bars etc. along with marking the boundaries & General arrangement of all switchyard Structures, Equipment, Installations, Bus-Bars/ Bays of all voltage levels along with all the empty Spaces/ Land in the Switchyard & adjoining area under UPPTCL after necessary Survey at site. . Brief description of work is as follows-
132KV Switchyard extension for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV feeder bays (if feasible) along with shifting/ modification as needed to accommodate required installations on as is where is basis with single main and transfer scheme at 132KV Voltage level. The designs of extensions/modifications shall follow/ conform to the existing practices being adhered in UPPTCL / existing structure designs already approved by the design wing of UPPTCL.The detailed drawings including necessary required revisions shall be submitted in three sets of hard copies on A-1 size sheets and one set of soft copy in PDF format for 132/33 kV system.
Preparation and submission of Electrical Layout Drawing of existing network and Proposed extensions for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV feeder bays (if feasible) along with shifting/ modification as needed to accommodate required installations on as is where is basis. The ELD will incorporate type of Structures, Equipment names, Interconnections, Measurements etc. along with all installations like O/H & U/G lines and EHV columns/towers.The detailed drawings including necessary required revisions shall be submitted in three sets of hard copies on A-1 size sheets and one set of soft copy in PDF format for 132/33 kV system.
Preparation and submission of Single Line Diagram & Sectional Drawings of existing network and Proposed extension for addition of 3 nos. 132 kV feeders including required proposal for provision of one or two more 132 kV feeder bays (if feasible).
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
BOQ_2094185.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid