Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹7.6 L+₹41,800 (5.82%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹8.1 L+₹93,800 (13.1%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s adrsh Enterprises L2 | J S B INFRA L3 | MAA MUNDESWARI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00Work for LT Line | ||||||
| 1.01 | Repairing of 8/9 Meter damage/rusted steel tubular pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast. | 20 | Job. | 6,000 ₹1,20,000 | 6,500 ₹1,30,000 | 5,500 ₹1,10,000 Lowest |
| 1.02 | Replacement of 8/9 Mtr. L.T. Damage Pole with STP/PCC pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast including carriage of new pole From Store to site & Damage pole from site to store (excluding PCC Pole) and other necessary work with material eg. earthing of pole, Shackle Insulator, Holding Clamp, Nut & Bolts of different Size Cross Arm. | 20 | Job. | 8,200 ₹1,64,000 | 8,500 ₹1,70,000 | 7,980 ₹1,59,600 Lowest |
| 2.00Work for 11 K.V. Line | ||||||
| 2.01 | Repairing of 9/11 Meter damage/rusted steel tubular pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast. | 20 | Job. | 6,500 ₹1,30,000 | 7,000 ₹1,40,000 | 5,980 ₹1,19,600 Lowest |
| 2.02 | Replacement of 9/11 Mtr. 11 KV Line Damage Pole with STP/PCC pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast including carriage of new pole From Store to site & Damage pole from site to store (excluding PCC Pole) and other necessary work with material eg. earthing of pole, Shackle Insulator, Holding Clamp, Nut & Bolts of different Size Cross Arm. | 20 | Job. | 8,800 ₹1,76,000 | 9,000 ₹1,80,000 | 8,450 ₹1,69,000 Lowest |
| 3.00Work for 33 K.V. Line | ||||||
| 3.01 | Repairing of 9/11 Meter damage/rusted steel tubular pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast. | 10 | Job. | 7,000 ₹70,000 | 7,200 ₹72,000 | 6,600 ₹66,000 Lowest |
| 3.02 | Replacement of 11/13 Mtr. 33 KV Line Damage Pole with STP/PCC pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast including carriage of new pole From Store to site & Damage pole from site to store (excluding PCC Pole) and other necessary work with material eg. cross arm, earthing of pole, Shackle Insulator, Holding Clamp, Nut & Bolts of different Size | 10 | Job. | 10,000 ₹1,00,000 | 12,000 ₹1,20,000 | 9,400 ₹94,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
9 Jul 2026, 3:00 pmClosed
SUPERINTENDING ENGINEER
UEDC-II, CHANDRIKA NAGAR COLONY, SIGRA, VARANASI
The work for maintenance and repair of L.T Line, 11 K.V. Line and 33 K.V. Line (Pole replacement, repairing of S.T.P. etc.) to ensure uninterrupted supply in the area of UEDD-Machhodari, Varanasi
2026_PVVNV_1165399_1
13/UEDC-II(V)/2026-27
Open Tender
Electrical Works
Lump-sum
365 days
UEDD- MACHHODARI, VARUNAPAR
PLEASE REFER AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,835
Yes
EE, UECD-II, VARANASI
₹10,000
Yes
15 Jul 2026
1 Jul 2026
9 Jul 2026
1 Jul 2026
9 Jul 2026
1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Work for LT Line | |||||
| 1.01 | Repairing of 8/9 Meter damage/rusted steel tubular pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast. | 20 | Job. | - | - |
| 1.02 | Replacement of 8/9 Mtr. L.T. Damage Pole with STP/PCC pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast including carriage of new pole From Store to site & Damage pole from site to store (excluding PCC Pole) and other necessary work with material eg. earthing of pole, Shackle Insulator, Holding Clamp, Nut & Bolts of different Size Cross Arm. | 20 | Job. | - | - |
| 2Work for 11 K.V. Line | |||||
| 2.01 | Repairing of 9/11 Meter damage/rusted steel tubular pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast. | 20 | Job. | - | - |
| 2.02 | Replacement of 9/11 Mtr. 11 KV Line Damage Pole with STP/PCC pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast including carriage of new pole From Store to site & Damage pole from site to store (excluding PCC Pole) and other necessary work with material eg. earthing of pole, Shackle Insulator, Holding Clamp, Nut & Bolts of different Size Cross Arm. | 20 | Job. | - | - |
| 3Work for 33 K.V. Line | |||||
| 3.01 | Repairing of 9/11 Meter damage/rusted steel tubular pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast. | 10 | Job. | - | - |
| 3.02 | Replacement of 11/13 Mtr. 33 KV Line Damage Pole with STP/PCC pole by digging of pit around the pole of size 1.0 mtr x 1.0 mtr x 1.0 mtr is to be done for proper positioning and then cleaning of rust and descaling with the help of hard wire brush & chisel and then putting 3 Nos. angle size 50x50x10 mm, 3 ft long properly welding the angles around pole to give robust structure. After completing of above work grouting and muffing of pole 300 mm above ground level with cement, concrete, sand and bricks ballast including carriage of new pole From Store to site & Damage pole from site to store (excluding PCC Pole) and other necessary work with material eg. cross arm, earthing of pole, Shackle Insulator, Holding Clamp, Nut & Bolts of different Size | 10 | Job. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
13-UEDC-II.26-27.docx
Tender Documents • 0.09 MB
BOQ_2185739.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .