Loading…
Loading…
Tender Value
₹2.7 Cr
EMD Value
₹5.4 L
Closing Date
26 Jun 2026, 3:00 pm
Various Telecom Works in connection with (i) Augmentation of existing SSE Signal store depot at Bhusawal (BSL) & Manmad (MMR) office and construction of new SSE office & store depot at Jalgaon(JL) on BSL division. (ii) Provision of Railnet connectivity at ROH Depot Bhusawal. (iii) Provision of telecom facilities at Admin Building ACL/BSL.(iv) Provision of internet connectivity at store shed/ACL/BSL (V) Development of Infrastructure and other needs of Railway school
BSL-N-SNT-01-2026-27
BSL-N-SNT-01-2026-27
Open
6 Months
Jalgaon, Maharashtra
₹0
₹5.4 L
5 Jun 2026
5 Jun 2026
12 Jun 2026
A-Augmentation of existing SSE Signal store depot at Bhusawal (BSL) & Above/
Supply, Testing & Commissioning of Isolator Device to isolate the circuit in case of short circuit, complying to the RDSO/SPN/217/2025 Ver 3.1 or latest.(Inspection by RDSO)
B-Augmentation of existing SSE Signal store depot at Bhusawal (BSL) &
Supply of United Office/Visitor chairs with Seat Depth 580 mm X Width 550 mm X 1 Height 890 mm Padded with polyurethane Foam (UNITED EXECUTIVE VISITOR CHAIR) Product ID :- 5116877-79082684271 (UNITED INDIA INTERPRISES STEEL ALMIRAH2000 mm 5 SHELVES AS PER GEM CONTRACT ATTATCHED) (Inspection by Consignee)
Supply of REVOLVING Counter Chair. (Inspection by Consignee)
Supply of Office Table Make- Godrej Model-T-104 Or Similar for PCCM's Office. (Inspection by Consignee)
Supply of 5 Door Locker Set - Overall size of 4 - Door Locker shall be 380mm(W)x450mm(D)x1830mm(H). Locking shall have 10 Lever cam lock with lock lever plus option of hasp arrangement . (Inspection by Consignee)
Supply of STP CAT-6E Networking Cable, having identification marks at regular interval, make D-Link OR Finolex OR Sterlite OR Digilink (Inspection by Consignee)
Supply Installation Testing & Commissioning of 8 port 1U Rack type, GPON Optical Line Terminal ,(4 GE Optical/Electrical uplink ports , 2 X10GE Ports SFP Ports ) as per TEC specification: TEC/GR/FA/PON-002/02/NOV- 18 or latest. [Inspection by RITES]
Supply of GPON C+ Fiber SFP module 20Km, conforming to clause mentioned in Chapter No. III of tender documents [Inspection by RITES]
Supply Installation Testing & Commissioning of GPON ONT and Wi-Fi (with Power Adapter)(Supply of wireless N GPON HGU with 4 port GbE as per TEC specification: TEC/GR/FA/PON- 002/02/NOV-18 or latest Switch). [Inspection by RITES]
Supply Installation Testing & Commissioning of GPON Splitter 1:4 .Make -Optilink or Similar. (Inspection by Consignee)
Supply Installation Testing & Commissioning of GPON Splitter 1:8 .Make -Optilink or Similar. (Inspection by Consignee)
Supply Installation Testing & Commissioning of GPON Splitter 1:16 .Make -Optilink or Similar. (Inspection by Consignee)
Supply Installation Testing & Commissioning o f 1:4 Fiber Distribution Hub Make - Optilink or Similar. (Inspection by Consignee)
Supply Installation Testing & Commissioning o f 1:8 Fiber Distribution Hub Make - Optilink or Similar.(Inspection by Consignee)
Supply of 2 Port Fiber termination Unit with pigtails. (Inspection by Consignee)
Supply of Fiber SC-SC Single mode duplex patch cord 4 mtr. (Inspection by Consignee)
Supply of OFC cable 6- core fibre armoured single mode . Make:- HFCL / Finolex / Paramount or similar. (Inspection by Consignee)
Termination / splicing of 6- core OFC cable. This includes supply & mounting of the termination box. All other sandry items required for the execution of the work is to be supplied by the contractor.
Laying & dressing of 6- core OFC cable. All other sandry items required for dressing of the cable to be supplied by the contractor.
Supply and fixing of PVC casing caping 25mm size for indoor wiring. This includes drawal of wires in the casing caping and termination of wire at end point. The work should be carried out as per the instruction of Railway site Engineer. (Inspection by Consignee)
Supply of Spike Guard (4 No. of - 5 Pin 6 Amp Sockets, Length of cable with Extension 1.5 Metre) Make -Anchor or similar. (Inspection by Consignee)
Supply of Optical fibre termination box for 2 x 24 fibre armoured cable complete with all accessories with the fixing arrangement to accommodate all the fibres as per specification No. IRS:TC:81-2000 (with latest amendment). (Inspection by Consignee)
"Supply and installation of Wall Mounted Water Purifier with RO+UV+UF Purification Technology with TDS controller along with Iron Guard as per annexure attached. Firms Offer MAKE/BRAND:-KENT" (Inspection by Consignee)
All in One desktop HP MAKE MODEL No.HP 440 G9 AIO i7 12700 32GB RAM SCREEN SIZE:23.8 (Inspection by Consignee)
Where-ever depth of 0.5 m cable trench is not feasible cable shall be protected as 25 under :- Preparation of cement mixture 1:3:6 with contractor's own materials land spreading cement l concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. (Inspection by Consignee)
Supply of 2 KVA UPS input 160 V to 260 V AC operating with battery and back up upto 2 hrs Make :-Power safe or APC or Luminous, Microtek or higher. (Inspection by Consignee)
Supply of On line 3 KVA UPS with batteries backup for 60 Minutes, input power single phase 160V - 260V sine wave 50 HZ output power single phase 230 Volt, +/-1%sine wave 50 Hz, Onsite OEM warranty 3 Years (Battery & UPS Both) with supply & Installation or any higher specification. Make - Microtek, Luminous, Artis, V-guard or Similar. (Inspection by Consignee)
Supply of 20 Pair CT Box Wago Type made up of at least 18 SWG galvanised MS 28 sheet, spray painted Gray Colour, locking arrangenment,Termination of 0.9 mm U/GQuad cable, it includes supply of Hylem Sheet 12mm thick,Nuts, Bolts, suitable size of GI Pipe for Fixing on the wall forU/G Quad Cable, with disconnection facility.(Inspection by Consignee)
Fixing of DP Box/CT Box This includes supply of Hylum Sheet 12mm thick, Nuts,Bolts, suitable size of GI Pipe for Fixing on the wall for U/G Cable. As per the Railway site Engineer conforming to clause mentioned in Chapter No. IVof tender documents. (Inspection by Consignee)
"Supply and installation of Layer 2 managed Gigabit Switch for HQ LAN (Servers), with minimum 24 ethernet 10/100/1000 Base-T ports Having RSTP protocol, PoE+, IPV6 support," (Inspection by RDSO)
"Supply of 8 port 10/100/1000 base T layer-2 smart managed POE switch with 2 nos. of SFP Gigabit uplink port make & model-Zyxel GS 1900 10 or HP or Digisol. Accepted Make DIGISOL 1510PL " (Inspection by RDSO)
"SUPPLY OF 4 PORT ROUTER AS PER RDSO SPECIFICATION: RDSO/SPN/TC/84/2008, REV.0 WITH ACCESSORIES AS: 2 ON BOARD GE, 4 PORT SERIAL WAN INTERFACE CARD, 2E HWIC 32 SLOTS, 1 ISM SLOTS, 256MB CF DEFAULT, 512MB RAM, IP BASE, 2 NOS.V35 CABLE, DTE MAKE TO SMART SERIAL 10 FEET LENGTH WITH REQUIRED CABLE & CONNECTION. Make: TECHROUTE/TSR- 2900-20 ROUTER+ 2x HIC-2TB Make:- CISCO MODEL No. ISR 4221/K9 or Similar Firm's Offer - Make - CISCO (Router Model - C8200L-1N-4T and accessories as per Annexure-B of the offer)" (Inspection by RDSO)
Supply of single line hand free push button Caller ID Telephone. Make: Model : Panasonic KX-TS880 or similar as per specification attached. Firm's offer- MAKE:-"ALACATEL" (Inspection by Consignee)
Supply and installation of 19 inches 9U rack wall mountable, conforming to Clause No. 3.9 of Chapter No. III and installation conforming to Clause No. 4.7 of Chapter IV of tender document. (Inspection by Consignee)
Supply of TP-Link 3000 Gigabits per Second 5 GHz WiFi 6 AX3000 Smart WiFi. (Inspection by Consignee)
Supply of 0.5MM Dia 10 Pair, Switch board cable as per TEC spec.No.GR/WIR-06/03, march 2002 or latest. Make - Delton or similar Make: DKE. Supplies shall conform to TEC Specifications & not TEC Approved. (Inspection by Consignee)
Supply of fixed BOX Bullet type IP Colour Camera 4 MP (Inspection by RITES)
Supply, of server hardware for 32 channel Network Video Recorder NVR Supply Portion. (Inspection by RITES)
Supply of Internal Storage HDD 10 TB with all accessories, similar to Seagate Windows Surveillance Internal Hard Drive HDD or equivalent or higher. (Inspection by Consignee)
Supply of DIGITAL EXTENSION Add On Gateways And Accessories For Pabx System 1 Port Make Anda TELECOM or Similar. (Inspection by Consignee)
Supply of Universal Gateway Add On Gateways And Accessories For Pabx System 24 Port Make Anda TELECOM or Similar. (Inspection by RITES)
Supply of Unbranded Simplex Fiber Optic Patch Cord LC - E 2000. (Inspection by Consignee)
Supply of Simplex Fiber Optic Patch Cord SC - SC (Inspection by Consignee)
Supply of Gigabit 2 Port PoE Extender,1 in 2 Out PoE Passthrough Switch PoE Injector, 10/100/1000 Mbps, 60W 48V IEEE 802.3af/at Power-Over-Ethernet Repeater, 6KV Lightning Protection along with all accessories. (Inspection by Consignee)
Supply of Optical Light Source SM 1310/1550nm Mini Fiber Optic Power Meter Fiber Optic Light Source, along with all accessories. (Inspection by Consignee)
Supply of telecommunication tools set 53 pieces at least including various screw drivers and soldering iron. Make: 89-883-23U Stanley. (Inspection by Consignee)
Supply of Optical Time Domain Reflectometer (OTDR) of reputed brand as per specification or latest.(Inspection by RITES)
Supply of power cable 3 Core copperx(PVC nsulated flexible 3 core x 2.5 sq mm multi strand power cables should conform to specification no. IS: 694:1990 reaffirmed 1995 or latest.) Make: Delton /Finolex or similar. (TO BE INSPECTED BY RITES)
Laying and Drawing of Power cable through 25 mm PVC Conduit pipe. This includes Fixing of PVC pipe/casing capping on wall, bridges, platforms complete with U clamp & necessary fixtures, screws etc. as per instructions of Rly. Engineer.
Supply of four port LAN Extenders, 2 Mbps GSHDSL. (Inspection by Consignee)
"Supply of 28 port L3 switch with 24 SFP port with pre-installed models for Four nos of Uplink Network ports with 10 Gigabit Ethernet, all 24 SFP shall be suitable for single fiber working, as 51 per RDSO Spec No. RDSO/SPN/TC/83/2020 Rev.2, amendment 1 or later. Model CISCO 3850 24s-s 28 port L3 OR CISCO 9300 of Make Cisco OR Extreme OR Juniper OR better model. The SM type SFP Modules 10 Gigabit, suitable for Single fiber working shall be supplied and pre-installed with all of the 28 ports of the switch."(Inspection by RDSO)
Supply of All in one Crimping Tool for crimping RJ45,RJ12, RJ11 modular connectors, with flat cable cutter and striper steel construction with ratchet mechanism. (Inspection by Consignee)
Supply of RJ 45 Connector Make- D-Link ,DAX, Schneider, Molex,amp. Accepted make/brand -D-Link. (Inspection by Consignee)
"Supply of FXO/FXS gateway 16 port as per RDSO/SPN/TC/99/2023 Ver 3 or latest or latest. This item should be compatible with existing VOIP Based TCCS on Bhusawal Div." (Inspection by Consignee)
C-Provision of Railnet connectivity at ROH Depot on Bhusawal Division
Supply of Layer 2 Managed Switch rack mountable 230V AC/48V DC operated as per clause of No. 4 of RDSO Specification No. RDSO/SPN/TC/83/2014 Rev. 1.0 Amendment 1.0 or later 1 with following- a) Power cable shall be suitable to Indian industry standard. b) Gigabit Ethernet LX Mini-GBIC SFP Transceiver-4 Nos. c) All 24 ports shall be non POE type. It should be of 24Port 10/100/1000 + 4 x 1Gig SFP port stackable . Switching capacity min. 56Gbps, IPV6, 16K MAC, 4K VLAN. with 4 No of SFP with single fiber module. (Inspection by RITES)
Supply of Aerial OFC 6 Fibre core single mode Optical Fibre Cable. (Inspection by Consignee)
Supply of PVC conduit pipe 25mm ISI marked heavy as per IS 9537 part-III 1983 standards. (Inspection by Consignee).
Laying & fixing PVC conduit pipe (conduit pipe must be fixed with clamp at interval of 300mm).
Supply of 24 fibre OFC Splice enclosure FIBRE OPTIC FIBRE SPLICE STRAIGHT JOINT ENCLOSURE ( SJC ) complete with all accessories as per RDSO/SPN/TC/68/2014, rev. 3 or specs for 24 fiber ofc cable with later amendment. (Inspection by Consignee)
Supply of 12 Port LIU Rack mountable LIU should be provided for terminating the Optic Fibre cables. It shall provide minimum bending radius and the splice trays shall function as a 6 splice cover for pigtail splicing. Cable glands shall be provided for secured anchoring of incoming cables, Rubber grommets shall be provided at the cable entry point for tight sealing, The splice tray shall be made of ABS materials, LIU should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. D-Link OR 3M OR DigiLink OR MOLEX. D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Supply of Optic Fiber Pigtails for termination of OFC cables. Pigtail should be single 7 mode SC/ST type with push-pull mechanism or as per site requirement and fully in compliance with latest industry standard. Optic fiber pigtails should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Installation and commissioning of 12 Port LIU with all accessories. as per instructions of the Railway Engineer.
Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/TERMINAL JOINTS 9 through fusion splicing for termination of OFC cables. The Fibers terminated shall be tested and test report (Hard copy and Soft copy ) shall be submited to the Railways site Incharge for records. Each fiber shall be properly marked with necessary ferrules/tags, as per instructions of the Railway Engineer.
Supply of 12 fiber single mode armoured equivalent to Polycab armoured single mode optical fibre ITU-G 652D. Firm's Offer:MAKE/BRAND:FINOLEX (Inspection by Consignee)
"Supply of fiber distribution management system for 24 fiber complete (48 fibres complete alongwith Euro adopters, pigtail) of make BIRLA, 3M, TVS, R&M, or latest superior make as per instruction of site incharge. (Inspection by Consignee) "
Installalation of FDMS with all installation materials, restoration wall etc. to original condition alongwith Splicing and Termination of optical fibres 2x24 fiber cable, routing/dressing fibers as per directions of site engineer.
Excavation of cable trench as per cable route plan,1.2 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer 13 of 50mm thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805
Excavation of cable trench as per cable route plan,1.2 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 14 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805
Horizontal boring of cable duct of minimum 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for other locations with minimum depth reckoned from the ground level. The work shall be done as per extant practice & instructions of site Engineer. Preparation of site for Horizondal 15 boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. BORING upto the length of 150 mtrs. Preparation of site for Horizondal boring shall be carried out in presence of Railway Representative.
Cutting of all types of Roads/ platforms (ecxcept concrete type) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. Drg. No. SK 807
Digging of trench1.0 M. deep from rail flange/road level (for LC) and 0.3Mtrs. to .6 17 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806
Supply of PLB HDPE Pipe (Duct)as per RDSO Specification No. RDSO/SPN/TC/45/2013 Rev 2.0 with amendment 2 or later, with accessories such as end plug etc. (Inspection by Consignee)
Laying of HDPE Pipe on the wall structures/ surfaces and inside the Trenches as per instructions of the Site Engineer In Charge, depending upon the site conditions, as per instructions of the Railway Engineer.
Drawing and Laying of Optical Fiber Cable and any other cable in already laid HDPE Pipe,and on open and under shed as per instructions of the Railway Engineer.
Supply and installation of 19 inches 9U rack wall mountable, conforming to Clause No. 3.9 of Chapter No. III and installation conforming to Clause No. 4.7 of Chapter IV of tender document. (Inspection by Consignee)
Supply of 50 mm x 50 mm PVC Cassing Capping on Walls with all accessories like T, Bends etc. This includes laying of switchboard Cables inside the PVC Casing.(Inspection by Consignee)
Fixing of PVC Casing Caping
Supply of STP CAT-6E Networking Cable, having identification marks at regular interval, make D-Link OR Finolex OR Sterlite OR Digilink (Inspection by Consignee)
Laying and Drawing of Data Communication cable, CAT cable, OFC through 25 mm PVC Conduit pipe. This includes Fixing of PVC pipe/casing capping on wall, bridges, platforms complete with U calmp & necessary fixtures, screws etc. as per instructons of Rly. Engineer
Supply of Online UPS of Rating 1.0 KVA With Battery Of Backup Time 60 Minutes Brand: Delta or similar (Inspection by Consignee)
Supply of OFC PATCH CARD SC TO LC,LC TO LC,SC-TO SC as per site requirement. (Inspection by Consignee)
Supply of Cat-6 Patch Chord 3 MTRs Both end factory crimped. (Inspection by Consignee)
Supply of OFC to Ethernet media converter. (Inspection by Consignee)
Supply of LAN TESTER. (Inspection by Consignee)
Supply of Crimping Tool. (Inspection by Consignee)
Supply of TP-Link 3000 Gigabits_per_Second 5 GHz WiFi 6 AX3000 Smart WiFi Router. (Inspection by Consignee)
Supply of 2 KVA UPS input 160 V to 260 V AC operating with battery and back up upto 2 hrs Make :-Power safe or APC or Luminous, Microtek or higher.(Inspection by Consignee)
Supply of RJ 45 connector. (Inspection by Consignee)
Supply of Cat 6 RJ 45 Patch panels 24 port, Offer accepted Brand : DURANET (Inspection by Consignee)
Supply of I/O Box Make- D-Link. (Inspection by Consignee)
Supply of 8 Port Gigabit Smart Managed Switch with 2 SFP Port. (Inspection by Consignee)
D-Provision of telecom facilities at Admin Building ACL/BSL
Supply of Layer 2 Managed Switch rack mountable 230V AC/48V DC operated as per clause of No. 4 of RDSO Specification No. RDSO/SPN/TC/83/2014 Rev. 1.0 Amendment 1.0 or later 1 with following- a) Power cable shall be suitable to Indian industry standard. b) Gigabit Ethernet LX Mini-GBIC SFP Transceiver-4 Nos. c) All 24 ports shall be non POE type. It should be of 24Port 10/100/1000 + 4 x 1Gig SFP port stackable . Switching capacity min. 56Gbps, IPV6, 16K MAC, 4K VLAN. with 4 No of SFP with single fiber module. (Inspection by RDSO)
Supply of Arial OFC 6 Fibre core single mode Optical Fibre Cable. (Inspection by Consignee)
Supply of Cat-6 cable with identifications marking on cable at regular interval of make D- Link, Optilink, Digilink, Baton, Network, Krone or similar . (Inspection by Consignee)
Laying and Drawing of Data Communication cable, CAT cable,ofc through 25 mm PVC Conduit pipe. This includes Fixing of PVC pipe/casing capping on wall, bridges, platforms complete with U calmp & necessary fixtures, screws etc. as per instructons of Rly. Engineer
Supply of PVC conduit pipe 25mm ISI marked heavy as per IS 9537 part-III 1983 standards. (Inspection by Consignee).
"Laying & fixing PVC conduit pipe (conduit pipe must be fixed with clamp at interval of 300mm). (Inspection by Consignee)."
TP-Link 3000 Gigabits_per_Second 5 GHz WiFi 6 AX3000 Smart WiFi Router. (Inspection by Consignee)
Supply and installation of 19 inches 9U rack wall mountable. (Inspection by Consignee)
Supply of PVC Switch board cable 20 Pair 0.5mm dia twisted pair PVC insulated, pvc sheathed ATC Copper conductor as per Tech. Spec. no. GR/W/R/06 make Bharat Cab , Delton Cable, Network Cable. (Inspection by Consignee)
Supply of PVC Switch board cable 05 Pair 0.5mm dia twisted pair PVC insulated, pvc sheathed ATC Copper conductor as per Tech. Spec. no. GR/W/R/06 make Bharat Cab , Delton Cable, Network Cable. (Inspection by Consignee)
Supply of 25 mm x 38 mm PVC Cassing Capping on Walls with all accessories like T, Bends etc. This includes laying of switchboard Cables inside the PVC Casing. (Inspection by Consignee)
Supply of PVC casing & Capping size 50mm x 50mm x 1mm thickness of Make Precision/Presto plat/Presto teak. (Inspection by Consignee)
Fixing of PVC Casing Caping
Supply of UPS 1.0 KVA,Indicative Back-up time: 30 Minutes at full load I. The UPS shall 14 be pure sine wave online UPS of capacity 1.0 KVA. The output power factor shall be 0.9. II. Both the rectifier and the Inverter shall be IGBT based. (Inspection by Consignee)
Supply of 2 KVA UPS ( Two Hours battery backup) (Inspection by Consignee)
Supply of RJ45 connector. (Inspection by Consignee)
Supply of OFC PATCH CARD SC TO LC,LC TO LC,SC-TO SC 5 Mtrs as per site requirement. (Inspection by Consignee)
Supply of Cat-6 Patch Chord 3 MTRs Both end factory crimped. (Inspection by Consignee)
Supply of Cat-6 Patch Chord 1 MTRs Both end factory crimped. (Inspection by Consignee)
Supply of OFC to Ethernet media converter. (Inspection by Consignee)
Supply of Lan tester. (Inspection by Consignee)
Supply of Crimping Tool. (Inspection by Consignee)
Supply of UTP 24 Port patch panel with RJ-45 jack 180 Degree Fully Loaded with all necessary accessories Make D-Link, Krone, Digilink or Similar. (Inspection by Consignee)
Supply of I/O Box Make- D-Link. (Inspection by Consignee)
Supply of CT Boxes/DP box (for 20 Pairs) in metal box with locking arrangement and terminal strip of Brass Nut, bolt and termination of quad cable/pijf cable in DP duly mounted on good quality Teak wood/hylum board [Inspection by Consignee]
Fixing of DP Box/CT Box This includes supply of Hylum Sheet 12mm thick, Nuts, Bolts, suitable size of GI Pipe for Fixing on the wall for U/G Cable. As per the Railway site Engineer
Supply and installation of Toughened Moulding Composite ( TMC) DP BOX for 50 pair with Krone Module along with mounting arrangement,size of DP.BOX should be 250MMx250MMx160MM.(Make: SINTEX or NATIONAL or KRONE).(Inspection by Consignee)
Supply & Installation of Professional 19"Equipment Racks 36U for housing central equipment of CCTV system complete with all fittings including DC fan 48V)- 2 Nos. and AC power distribution panel (horizontal fitting) with power sockets and fuse protection (minimum 6 nos. of 28 230V 15A/5A combined) and other accessories. The body should be of high quality cold rolled steel with wheel and caster arrangements, vented from door boarders and rear doors for ventilation and reliable operation. All the accessories and fixing arterials required for this installation are to be supplied by the vendor free of cost make president/ HCL/ APW/ Valrack as per spec. annexure server rack. (Inspection by Consignee)
Supply of 12 Port LIU Rack mountable LIU should be provided for terminating the Optic Fibre cables. It shall provide minimum bending radius and the splice trays shall function as a 29 splice cover for pigtail splicing. Cable glands shall be provided for secured anchoring of incoming cables, Rubber grommets shall be provided at the cable entry point for tight sealing, The splice tray shall be made of ABS materials, LIU should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Supply of Optic Fiber Pigtails for termination of OFC cables. Pigtail should be single 30 mode SC/ST type with push-pull mechanism or as per site requirement and fully in compliance with latest industry standard. Optic fiber pigtails should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Installation and commissioning of 12 Port LIU with all accessories. as per instructions of the Railway Engineer.
Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/TERMINAL JOINTS through fusion splicing for termination of OFC cables. The Fibers terminated shall be tested and test report (Hard copy and Soft copy ) shall be submited to the Railways site Incharge for records. Each fiber shall be properly marked with necessary ferrules/tags, as per instructions of the Railway Engineer.
E-Provision of internet connectivity at store shed/ACL/BSL
Supply of Layer 2 Managed Switch rack mountable 230V AC/48V DC operated as per clause of No. 4 of RDSO Specification No. RDSO/SPN/TC/83/2014 Rev. 1.0 Amendment 1.0 or later 1 with following- a) Power cable shall be suitable to Indian industry standard. b) Gigabit Ethernet LX Mini-GBIC SFP Transceiver-4 Nos. c) All 24 ports shall be non POE type. It should be of 24Port 10/100/1000 + 4 x 1Gig SFP port stackable . Switching capacity min. 56Gbps, IPV6, 16K MAC, 4K VLAN. with 4 No of SFP with single fiber module. (Inspection by RDSO)
Supply of Arial OFC 6 Fibre core single mode Optical Fibre Cable. (Inspection by Consignee)
Laying and Drawing of Data Communication cable, CAT cable,ofc through 25 mm PVC Conduit pipe. This includes Fixing of PVC pipe/casing capping on wall, bridges, platforms complete with U calmp & necessary fixtures, screws etc. as per instructons of Rly. Engineer
Supply of 12 Port LIU Rack mountable LIU should be provided for terminating the Optic Fibre cables. It shall provide minimum bending radius and the splice trays shall function as a 4 splice cover for pigtail splicing. Cable glands shall be provided for secured anchoring of incoming cables, Rubber grommets shall be provided at the cable entry point for tight sealing, The splice tray shall be made of ABS materials, LIU should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Supply of Optic Fiber Pigtails for termination of OFC cables. Pigtail should be single 5 mode SC/ST type with push-pull mechanism or as per site requirement and fully in compliance with latest industry standard. Optic fiber pigtails should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Installation and commissioning of 12 Port LIU with all accessories. as per instructions of the Railway Engineer.
Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/TERMINAL JOINTS 7 through fusion splicing for termination of OFC cables. The Fibers terminated shall be tested and test report (Hard copy and Soft copy ) shall be submited to the Railways site Incharge for records. Each fiber shall be properly marked with necessary ferrules/tags, as per instructions of the Railway Engineer.
Supply of 19 inches 9U rack wall mountable, the depth of the rack shall not be less than 600 mm and 600 mm wide. (Inspection by Consignee)
Supply of 25 mm x 38 mm PVC Cassing Capping on Walls with all accessories like T, Bends etc. This includes laying of switchboard Cables inside the PVC Casing. (Inspection by Consignee)
Fixing of PVC Casing Caping
Supply of Cat-6 cable with identifications marking on cable at regular interval of make D- Link, Optilink, Digilink, Baton, Network, Krone or similar. (Inspection by Consignee)
Supply of UPS 1.0 KVA,Indicative Back-up time: 30 Minutes at full load I. The UPS shall be pure sine wave online UPS of capacity 1.0 KVA. The output power factor shall be 0.9. II. Both the rectifier and the Inverter shall be IGBT based.(Inspection by Consignee)
Supply of RJ45 connector. (Inspection by Consignee)
Supply of OFC PATCH CARD SC TO LC,LC TO LC,SC-TO SC 5 Mtrs as per site requirement. (Inspection by Consignee)
Supply of Cat-6 Patch Chord 3 MTRs Both end factory crimped. (Inspection by Consignee)
Supply of Cat-6 Patch Chord 1 MTRs Both end factory crimped.(Inspection by Consignee)
Supply of OFC to Ethernet media converter. (Inspection by Consignee)
Supply of Lan tester. (Inspection by Consignee)
Supply of Crimping Tool. (Inspection by Consignee)
Supply of CAT-6 U/UTP Cat 6 Patch Panel. (Inspection by Consignee)
Supply of I/O Box Make- D-Link. (Inspection by Consignee)
Horizontal boring of cable duct of minimum 2.0 Mtr depth along with laying of 120mm HDPE pipe for Other locations with minimium depth reckoned from the ground level, The work shall be done as per extant practice & instructions of site engineer. Preparation of site for Horizontal 22 Boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable BORING beyond 150mtrs. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative,
"Supply of 24 fibre straight joint closure (SJC) complete with all accessories as per 23 RDSO Spec. No.RDSO/SPN/TC/68/2007, Rev.0 Amendment No.1.1 or latest ammendments and as per or TEC Spec.G/OIJC/02/02 Sept 2003 or latest of Raychem make model FOSC 400 B4 24F or TVS ICS make model 1500-L1 83-XX or Birla VXL make model VT-200 or 3M make model 2179 CD. (Inspection by Consignee)
"Splicing (Jointing 2X24 F OFC ) and testing of 24 fibre OF Cable and making the 24 splice joint as per direction of site engineer with contractors own splicing machine & tools. Splice loss of each fibre should be less than or equal to 0.05db splice reflectance should be better than 60 db. "
"Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and 25 accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03/March 11 with latest amendment" for OFC cable of size 24 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources. (Inspection by Consignee) "
Laying of HDPE duct in trench and its protective work as per direction of site engineer.
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer.
"Laying of signalling/Power/Telecom cable of various cores/sizes in trenches."
Supply of thermo shrink Jointing kit (Reinforced) for quad cable conforming to RDSO Specification No. IRS: TC 77-2012 with ammendment 3 or later. (Inspection by RDSO)
Making of thermoshrink straight through/derivation/ transformer /PIJF cable joint for underground jelly filled cable 6 quad/4 quad/20 pair 10 pair etc. PIJF cable as per the instruction of Rly engineer at site.
Excavation of cable trench as per cable route plan,1.2 mt. deep and 300mm wide 31 along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805
F-Development of Infrastructure and other needs of Railway school.
SUPPLY AND INSTALLATION OF 32 CHANNEL 4K NETWORK VIDEO RECORDER with 2 Sata HDD AS PER THE DETAILED SPECIFICATION ENCLOSED. (Inspection by RDSO)
Supply of fixed BOX Bullet type IP Colour Camera 4 MP. (Inspection by RDSO)
Supply of 65 inch Android Smart Television with Direct LED Specification: Make & Model : equivalent to SONY Make, model-65X82L HDMI Ports : 04 No.s USB Ports : 02 No.s Ethernet Ports : 1 No Built in Wifi: YES Composite input :YES Component Input :NO RF Input :YES Built in setup Box :NO Details of Accessories :Remote Control, Connecting Cables, Batteries Screen Size :65 Inch 3 Resolution(Pixels) :(3840x2160) UHD Category :Smart Operating System :Android Digital Audio output : YES HDMI ARC -YES Backlight Type : Direct LED Built in Mic - YES Screen Mirroring :YES Mount Type :Both Table and Wall mount Inbuilt speakers :YES Wattage of Speakers -10Wx2 Subwoofer :No Warranty :1 years Type of Display Technology :Direct LED Only OEM/authorized dealer to be participate in the bid and concerned documents to be submit along with bid Accepted Make/Brand - Sony. (Inspection by Consignee)
Supply, of 8 Port unmanageable POE switch similar to unManaged Switch 8 Port PoE with wattage 65 watt similar to FES-GS-1008P or equivalent or higher. (Inspection by Consignee)
"Supply and installation of 4 TB HDD for NVR Firms Offer MAKE/BRAND:- CONSISTENT/DAICHI (Inspection by RDSO) "
Supply of LAN Extender as per RDSO specification No. RDSO/SPN/TC/82/2020 Rev. 2 .0 or latest. (Inspection by Consignee)
"Supply, installation, testing and commissioning of 4U Rack wall mount with complete accessories.(Inspection by Consignee) "
Supply and fixing of Round CCTV Camera Pole.(Inspection by Consignee)
Supply and fixing of Brackets(Angle) fabricated camera brackets including clamps, hardware, painting, camera guards, etc.(Inspection by Consignee)
Supply of Amici Care Waterproof Socket Switch with Power Indicator, 6/16Amp Outdoor Electric Switch Socket Box IP66. (Inspection by Consignee)
Supply of Intex Line Interactive UPS with AVR of Rating 1.0 KVA With Warranty of 1 Year Brand: Intex. (Inspection by Consignee)
G-Development of Infrastructure and other needs of Railway school.
Supply of Layer 2 Managed Switch rack mountable 230V AC/48V DC operated as per clause of No. 4 of RDSO Specification No. RDSO/SPN/TC/83/2014 Rev. 1.0 Amendment 1.0 or later 1 with following- a) Power cable shall be suitable to Indian industry standard. b) Gigabit Ethernet LX Mini-GBIC SFP Transceiver-4 Nos. c) All 24 ports shall be non POE type. It should be of 24Port 10/100/1000 + 4 x 1Gig SFP port stackable . Switching capacity min. 56Gbps, IPV6, 16K MAC, 4K VLAN. with 4 No of SFP with single fiber module. (Inspection by RDSO)
"Supply of The High throughput LAN extender shall be conforming to Central Railway Specification No. CR/SPN/TC/80/2015 revised on Dt. 28.11.2016. It shall have four LAN ports. Make of LAN Extender shall be Cygnus OR Anda OR MRO Tech" (Inspection by Consignee)
Supply of Cat-6 cable with identifications marking on cable at regular interval of make D- Link, Optilink, Digilink, Baton, Network, Krone or similar . (Inspection by Consignee)
Supply of RJ45 connector. (Inspection by Consignee)
Supply of OFC PATCH CARD SC TO LC,LC TO LC,SC-TO SC 5 Mtrs as per site requirement. (Inspection by Consignee)
Supply of D-Link Grey CAT6 U/UTP Patch cord 3.0 Mtrs Brand: D-Link (Inspection by Consignee)
Supply of D-Link Grey CAT6 U/UTP Patch cord 1.0 Mtrs Brand: D-Link (Inspection by Consignee)
Supply of Arial OFC 6 Fibre core single mode Optical Fibre Cable. (Inspection by Consignee)
Supply of 25 mm x 38 mm PVC Casing Capping on Walls with all accessories like T, Bends etc. This includes laying of switchboard Cables inside the PVC Casing. (Inspection by Consignee)
Fixing of PVC Casing Caping
Supply of I/O Box Make- D-Link. (Inspection by Consignee)
Supply of Cat 6 RJ 45 Patch panels 24 port, Offer accepted Brand : DURANET. (Inspection by Consignee)
Supply of 12 Port LIU Rack mountable LIU should be provided for terminating the Optic Fibre cables. It shall provide minimum bending radius and the splice trays shall function as a 13 splice cover for pigtail splicing. Cable glands shall be provided for secured anchoring of incoming cables, Rubber grommets shall be provided at the cable entry point for tight sealing, The splice tray shall be made of ABS materials, LIU should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Supply of Optic Fiber Pigtails for termination of OFC cables. Pigtail should be single 14 mode SC/ST type with push-pull mechanism or as per site requirement and fully in compliance with latest industry standard. Optic fiber pigtails should be of reputed make D-Link OR 3M OR DigiLink OR MOLEX. (Inspection by Consignee)
Installation and commissioning of 12 Port LIU with all accessories. as per instructions of the Railway Engineer.
Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/TERMINAL JOINTS 16 through fusion splicing for termination of OFC cables. The Fibers terminated shall be tested and test report (Hard copy and Soft copy ) shall be submited to the Railways site Incharge for records. Each fiber shall be properly marked with necessary ferrules/tags, as per instructions of the Railway Engineer.
Supply and installation of 19 inches 9U rack wall mountable, conforming to Clause No. 3.9 of Chapter No. III and installation conforming to Clause No. 4.7 of Chapter IV of tender document. (Inspection by Consignee)
Supply of PVC Switch board cable 10 Pair 0.5mm dia twisted pair PVC insulated, pvc sheathed ATC Copper conductor as per Tech. Spec. no. GR/W/R/06 make Bharat Cab , Delton Cable, Network Cable. (Inspection by Consignee)
Excavation of cable trench as per cable route plan,1.2 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm 19 thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805
Cutting of trench across the platform for a depth of 200 mm and width of 200 mm with marbel cutting machine and re-filling the trenches after laying of pipe/cables and restoring the surface with original tiles, as per instructions of the Railway Engineer.
Supply of DP Box 20 Pair with back mount frame including original krone module. (Inspection by Consignee)
"Supply of OFC MEDIA CONVERTER SINGLE FIBER working" (Inspection by Consignee)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022__POLICY_27_04_22.pdf
ATTACHMENT
CorrectionSlipsMergedGCC2022.pdf
ATTACHMENT
DrawingsSOR.pdf
ATTACHMENT
Annexure-ASafety-CriticalSignalingItemsbyRDSORSDte26.09.2025.1.pdf
ATTACHMENT
TenderBooklet01-26Final_2.pdf
ATTACHMENT
Download all tender documents and submit your bid