| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.9 L+₹255 (0.03%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.9 L+₹3,860 (0.44%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L3 | Rejected-AOC L3 | |
| 4 | L4₹9.3 L+₹47,440 (5.35%)Rejected-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L4 | Rejected-AOC L4 | |
| 5 | L5₹9.7 L+₹80,390 (9.07%)Rejected-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹19,900
Closing Date
10 Jun 2022, 6:00 pmClosed
AGE I TALBEHAT
LAKE VIEW CAMP MIL STN TALBEHAT 284125
REPAIR TO ROOF TREATMENT OF CERTAIN BLDGS IN ZONE 17 AND 14 AT MIL STN TALBEHAT
2022_MES_520317_1
AGE(I)/TBT/TOK-17/2022-23
Open Tender
Civil Works
Item Rate
180 days
MILITARY STATION TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I TALBEHAT
₹19,900
Yes
6 Aug 2022
27 Apr 2022
13 Jun 2022
4 May 2022
10 Jun 2022
11 May 2022
Amount
Taking down existing unserviceable roof treatment of any description including cement plaster/cement concrete of any thickness from roof surface cleaning of roof surfaces and preparing it for further treatment. Note: All debris obtained from taking down shall be removed 1.5 km to 2 km complete all as specified and as directed
Demolition cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
M & L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed
M & L for PCC 1:2:4 (B-0) using 12.5mm graded stone aggregate using WPC @3% by weight of cement as in roof top finished the surfaces even and smooth without using extra cement for laying roof treatment complete all as specified and as directed Note:- Water proofing compound shall be measured and paid separately
M&L for rendering 10mm thick in CM 1:4 on fair faces of brick work/concrete surfaces using WPC finished fair & even without using extra cement complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid separately
M&L for PCC 1:2:4 type Bo using 12.5mm graded crushed stone aggregate in roof kerb, junction of roof & parapet wall and other vertical surfaces complete all as specified and as directed
M&L for PCC 1:3:6, type C2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed
Taking down cement plaster on brick or stone walls, etc. incl racking out joints , hacking for key , scrubbing down with water etc. Note: All debris obtained from taking shall be removed 1.5km to 2km complete all as specified and as directed.
M&L for 15mm thick rendering on brick/concrete work surfaces in CM 1:4 finished fair and even without using extra cement complete all as specified and as directed
M&L for preparation of newly plaster surfaces of wall & applying two coats of cement base paint over a coat of primer complete all as specified and as directed
M&L of water proofing treatment to non accessible roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm, weight not less than 3Kg/Sqm as per manufacturers instruction with torch application complete all as specified and directed by Engineer-in-Charge with following course of description below: (a) First coat apply bituminous primer confirming to IS-3384of 1965 @ 0.4Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated (b) Second course of laying of APP based modified polymeric with 100mm overlap in longitudinal direction 150mm in transverse direction sealed and bounded to the surface by torch application method. All joints and changes in all direction should be covered with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane (c) Third course of apply a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrane Note:- (i)Work of water proofing treatment shall be carried out by the authorised applicator of the manufacturer. (ii) The quoted rates is deemed to include for the cost of scaffolding, T&P etc. required for execution of the work.
M&L of water proofing treatment to accessible roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm, weight not less than 3Kg/Sqm as per manufacturers instruction with torch application complete all as specified and directed by Engineer-in-Charge with following course of description below: (a) First coat apply bituminous primer confirming to IS-3384of 1965 @ 0.4Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated (b) Second course of laying of APP based modified polymeric with 100mm overlap in longitudinal direction 150mm in transverse direction and edges to be taken up to vertical wall of 20cm height inserted in to the vertical wall concealed the joint with bitumen sealant. All joints and changes in all direction should be covered with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane Note:- (i)Work of water proofing treatment shall be carried out by the authorised applicator of the manufacturer.
M&L for water proofing treatment including preparation of surface as required for roof treatment , balcony, terrace etc. consisting of following sequences of operation on RCC roof slab for non accessible roof surface M&L for providing and laying of fibre reinforcement elastomeric liquid water proofing membrane with resilient acrylic polymer having sun reflective index (SRI) of 105 manufactured by Asian Paints Ltd or equivalent as approved by AGE(I) on top of concrete roof with consumption @ 10.76 Ltr/10Sqm for three coats. One coat of self priming of elastomeric water proofing liquid (dilution with water in the ratio of 3 part of product and one part of water and two coat of undiluted elastomeric water proofing liquid (dry film thickness of complete treatment not less than 500 microns). The operation shall be carried out after scrapping and properly cleaned loosed particles with wire brushes, filled the crack upto 3mm with fibre glass reinforced crack filling compound 10, complete all as specified and as directed by Engr-in-Charge Note: The work of water proofing treatment shall be got executed through manufacturer or authorised applicator of the manufacturer .
M&L for cement concrete tiles 250mmX250mmX25mm / 300mmX300mmX25mm thick laid over 15mm cement screed bed in CM1:4 set and jointed with grey cement and no pigment and pointed in near cement slurry as in accessible roof surfaces
Supply only integral water proofing compound
Demolition of brick work or stone / boulder masonry , built in cement mortar incl all quoins , pillars etc.
M & L brick work with fly ash bricks straight or curved on plan exec 6 M mean radius with old size bricks in CM (1:6).
Dismantling water tanks of capacity exc 250Ltr and n.exc 500Ltr and complete all as specified and as directed
Dismantling water tanks of capacity exc 500Ltr and n.exc 1000Ltr and complete all as specified and as directed
S&F rotational moulded polyethylene water tank of 500Ltrs capacity (Cylindrical vertical with closed top) noticed and portion all as specified SSR Part-I complete all as specified and as directed by Engr-in-Charge
S&F rotational moulded polyethylene water tank of 1000Ltrs capacity (Cylindrical vertical with closed top) noticed and portion all as specified SSR Part-I complete all as specified and as directed by Engr-in-Charge
S&F 20mm ball value high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe all as specified and as directed
S&F in repairs gun metal globe or gate value, wheel head cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 20mm dia , ISI marked complete all as specified and as directed.
Taking up or down 15 mm dia steel tubing and connection including removal complete and all as specified and directed
Taking up or down 20 mm dia steel tubing and connection including removal complete and all as specified and directed
Taking up or down 25 mm dia steel tubing and connection including removal complete and all as specified and directed
S&F 15mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
S&F 20mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
S&F 25mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed.
Disconnecting existing water tanks exc 250ltr and n.exc 500ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc. from tank complete all as specified and as directed.
Disconnecting existing water tanks exc 500ltr and n.exc 1000ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc. from tank complete all as specified and as directed.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., and removal complete and all as specified and directed
S & F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls.
S & F for 110 mm bore PVC (SWR) bends of any radius including door system complete all as specified and as directed..
S&F for stack clamp out of 50mm by 3mm float iron and 16mm dia round iron stays fixed to pipe of bore 110mm complete all as specified and as directed
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
Allied Agencies
HARNAM SINGH ANIL SINGH
M/S SHIVA TRADERS
M/S Kharya Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .