Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAdmitted-Finance 135 139 BILAKHIA HOUSE MUKTANANAD MARG CHALA VALSAD GUJARAT 396191 | VALSAD | GUJARAT | 396191 | L1 | Admitted-Finance | |
| 2 | L2₹44.9 L+₹38.5 L (601.3%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Non compliance of MII order. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not submitted Performance certificate and DCGI licence as per bid terms. | |
| 5 | Rejected-Technical 135 139 BILAKHIA HOUSE MUKTANAND MARG CHALA VAPI VALSAD GUJARAT 396191 | VALSAD | GUJARAT | 396191 | - | Rejected-Technical Non compliance of MII order. |
| Sl No | Description | Qty | Unit | SRI SAI AGENCIES L2 | MERIL HEALTHCARE PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | Uncemented Total Hip Replacement in Normal Bone architecture (All sizes) | 1 | Mentioned in tender document | - | - |
| 2.00 | Acetabular cup | 1 | Mentioned in tender document | 29,983.8 ₹29,983.8 | 14,175 ₹14,175 Lowest |
| 3.00 | Polyethylene liner | 1 | Mentioned in tender document | 9,912 ₹9,912 | 7,875 ₹7,875 Lowest |
| 4.00 | Cancellous screws | 1 | Mentioned in tender document | 1,764 ₹1,764 | 735 ₹735 Lowest |
| 5.00 | Metallic head | 1 | Mentioned in tender document | 11,151 ₹11,151 | 5,775 ₹5,775 Lowest |
| 6.00 | Femoral stem | 1 | Mentioned in tender document | 28,691.25 ₹28,691.25 | 25,200 ₹25,200 Lowest |
| 7.00 | Uncemented Total Hip replacement components in normal bone architecture with ceramic head( All sizes) | 1 | Mentioned in tender document | - | - |
| 8.00 | Acetabular cup | 1 | Mentioned in tender document | 29,983.8 ₹29,983.8 | 14,175 ₹14,175 Lowest |
| 9.00 | Polyethylene liner | 1 | Mentioned in tender document | 9,912 ₹9,912 | 7,875 ₹7,875 Lowest |
| 10.00 | Cancellous screws | 1 | Mentioned in tender document | 1,764 ₹1,764 | 735 ₹735 Lowest |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
8 Nov 2022, 11:00 amClosed
DEAN
ESIC Medical College Hospital, K.K. Nagar, Chennai 78
e Tender for the Supply of Orthopedics Implants (Total Hip Replacement and Total Knee Replacement) under Rate Contract for ESIC Medical College Hospital, K.K. Nagar, Chennai 78 and ESIC ESIS Hospital Tamil Nadu for Two years
2022_ESIC_717235_1
Rate Contract of THR and TKR Implants
Open Tender
Consumables (Hospital / Lab)
Item Rate
21 days
ESIC Medical College Hospital, K.K. Nagar
As per tender terms
8 documents required · 8 mandatory
₹0
₹5 L
Yes
SM CHAMBER
14 Jan 2023
11 Oct 2022
9 Nov 2022
11 Oct 2022
8 Nov 2022
11 Oct 2022
17 Oct 2022
Uncemented Total Hip Replacement in Normal Bone architecture (All sizes)
Acetabular cup
Polyethylene liner
Cancellous screws
Metallic head
Femoral stem
Uncemented Total Hip replacement components in normal bone architecture with ceramic head( All sizes)
Acetabular cup
Polyethylene liner
Cancellous screws
Ceramic head
Femoral stem
Cemented total hip replacement (All sizes)
Cemented acetabular cup
Metallic femoral head
Cemented femoral stem
Femoral stem centraliser
Cement restrictor
Cement packet
Uncemented Total Hip Replacement in Osteoporotic bone with ceramic head (All sizes)
Acetabular cup
Polyethylene liner
Cancellous screws
Ceramic femoral head
Femoral stem
Uncemented Total Hip Replacement in Osteoporotic bone with metallic head (All sizes)
Acetabular cup
Polyethylene liner
Cancellous screws
Metallic femoral head
Femoral stem
Hybrid Total Hip Replacement uncemented acetabular component and cemented femoral component with ceramic head
Acetabular cup
Polyethylene liner
Cancellous screws
Ceramic femoral head
Femoral stem
Bone cement
Cement restrictor
Stem centraliser
Uncemented Total Hip Replacements in complex Primary situations where the proximal femur is deformed and also the acetabulum (All sizes)
Acetabular cup
Polyethylene liner
Cancellous screws
Ceramic femoral head
Femoral stem
Dual Mobility Total Hip replacement to used mainly in case where there is chances of dislocation after Total Hip replacement like fracture neck of femur and in abductor insufficiency etc. (All sizes)
Acetabular component
Cancellous screws
Femoral head
Femoral stem
Revision Total Hip Replacement withmain focus on the femoral side (All sizes)
Acetabular cup
Polyethylene Liner
Cancellous screws
Femoral head ceramic
Femoral stem with distal scratch fit
Cables
Revision Total Hip Replacement withfocus on both femoral side and acetabular side (All sizes)
Acetabular cup
Polyethylene Liner
Cancellous screws
Femoral head - ceramic
Femoral stem for revision
Cables
Revision Total Hip Replacement withfocus on both femoral side with various modularities and acetabular side especially in suspected abductor deficiency (All sizes)
Acetabular cup with dual mobility
Cancellous screws
Femoral head - ceramic
Femoral stem for revision
Cables
Revision Total Hip Replacement withfocus on both femoral side with various modularities and acetabular side ((All sizes)
Acetabular cup
Polyethylene Liner
Cancellous screws
Femoral head - ceramic
Femoral stem for revision with locking options
Cables
Revision Total Hip Replacement withfocus on both femoral side with various modularities and acetabular side (modular revision femoral stem) – (All sizes)
Acetabular cup
Polyethylene Liner
Cancellous screws
Femoral head - ceramic
Femoral stem for revision
Cables
Revision Total Hip Replacement withfocus on both femoral side with various modularities and acetabular side (modular revision femoral stem) with augments / buttresss in acetabulum (All sizes)
Acetabular cup
Polyethylene Liner
Cancellous screws
Femoral head - ceramic
Femoral stem for revision
Cables
Augments/buttress with screws and cement
Revision Total Hip Replacement withfocus on both femoral side and acetabular side with the need of augments/buttress in acetabulum and femoral side (All sizes)
Acetabular cup
Polyethylene Liner
Cancellous screws
Femoral head - ceramic
Femoral stem for revision
Cables
Augments/buttress with screws and cement
Bipolar Modular Arthroplasty uncemented for Hip joint (All sizes) - Including all the components
Bipolar Modular arthroplasty uncemented with distal fixing stem for hip joint in case of comminuted neck of femur fracture with comminuted greater trochanter - Including all the components
Bipolar Modular Arthroplasty Cemented for Hip joint (All sizes) -Including all the components
Primary Total Knee Replacement with Cobalt Chromium.(All sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Saw blades
Primary Total Knee Replacement with Cobalt Chromium with hi-flex category (All sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Saw blades
Primary Total Knee replacement made of Cobalt Chromium with the usage of intramedullary component (which can be fitted with primary femoral or tibial components ) in case of any bony defects. (All sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Femur intramedullary component with notch bolt if needed (uncemented or cemented)
Tibial Intramedullary component (uncemented/cemented)
Saw blades
Primary Total Knee Replacement made of Zirconium for femur component and Tibial component of titanium (Allsizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Saw blades
Primary Knee Replacement made of Cobalt Chromium with the need of any Augments or wedges along with Intramedullary component for femur and tibia in case of any big bones defect (All sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Femur intramedullary component with notch bolt if needed (uncemented or cemented)
Tibial Intramedullary component (uncemented/cemented)
Augments or wedges
Augments or wedges
Saw blades
Revision Total Knee Replacement Made of Cobalt Chromium (All sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Saw blades
Revision total Knee components made of cobalt chromium with the need of intramedullary stem in femur or tibial side - to manage the defect or strengthen the construct (All sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Femur intramedullary component with notch bolt if needed (uncemented or cemented)
Tibial Intramedullary component (uncemented/cemented)
Saw blades
Revision Knee Replacement made of cobalt chromium with the need of Intramedullary stem in femur or tibial side and in addition the augments and or wedges (all sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Femur intramedullary component with notch bolt if needed (uncemented or cemented)
Tibial Intramedullary component (uncemented/cemented)
Augments or wedges
Augments or wedges
Saw blades
This set is for Revision Total Knee Replacement made of cobalt Chromium with huge defects which needs the following components (all sizes)
Femoral component
Tibial component
Articulating surface
Patellar components
Femur intramedullary component with notch bolt if needed (uncemented or cemented)
Tibial Intramedullary component (uncemented/cemented)
Augments or wedges
Augments or wedges
Meta physeal sleeves / cones for tibia
Metaphyseal cones /sleeves for femur
Saw blades
Knee Replacement in joints which needs Constrained components (all sizes)
Constrained Total Knee Prosthesis
Saw blades
Unicondylar Knee replacement system (All sizes)
Unicondylar Knee set
Saw blades
Bipolar (cemented and Uncemented) Hemiarthroplasty prosthesis for Shoulder (Allsizes)
Bipolar Hemiarthroplasty set for shoulder joint
Saw blades
Total Shoulder Joint Replacement (all Sizes)
Total Shoulder Joint Replacement set
Saw blades
Reverse Shoulder Joint Replacement (All sizes)
Reverse Shoulder Joint Replacement set
Saw blades.
Total Elbow Replacement system (All sizes)
Total Elbow replacement
Saw blades
Tumour prosthesis for Total Knee Replacement
Tumour prosthesis Total Knee replacement
Saw blades
Tumour prosthesis for Total Hip Replacement
SRI SAI AGENCIES
MERIL HEALTHCARE PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .