Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.1 LAccepted-AOC | 1 | Accepted-AOC L-1 | |
| 2 | 2₹21.0 L+₹2.5 L (13.5%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹26.5 L+₹8.0 L (43.4%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 3 | Rejected-Finance Being other than L-1 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
9 Nov 2021, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
REPAIR/ MAINT AND CERTAIN MISC REPAIRS TO DRAINS, PATHS, CULVERTS, BOUNDARY WALL, FENCING GATES, GARBAG PITS ETC AT ZONE F AND PAO(OR) AMC CENTRE AND COLLEGE OF AGE BR-II UNDER GE (EAST) LUCKNOW
2021_MES_481170_1
GE/E/LKO/T-32 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Lucknow Cantt
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹49,000
Yes
10 Dec 2021
12 Oct 2021
10 Nov 2021
12 Oct 2021
9 Nov 2021
26 Oct 2021
Amount
Taking down cement plaster on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc but lime plaster any description complete all as specified and directed
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and directed
M&L for brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6M mean radius in half brick thick wall, old size brick built in cement mortar 1:4 complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work in CM1:6,finished even and smooth without using extra cement complete all as specified and directed
M&L for 15 mm thick rendering in CM 1:4 on external surfaces of walls & chajja/roof/ceiling facia at any height with liquid water proofing compound as per manufacturer's instructions, surface finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid seperately as "Supply only".
Supply only liquid water proofing compound ISI marked complete all as specified and directed.
M&L for rendering 5mm thick on concrete surfaces of ceiling in CM 1:4 complete all as specified and directed
M&L for 20 mm thick cement plaster in CM(1:3) mixing an integral waterproofing compound, Sika Cim @ 100 gms per bag of cement over 1st coat of Sika® Topseal 107, aacrylic polymer modified cementations waterproofing coating, including 2nd coat of Sika®Topseal 107, acrylic polymer modified cementations waterproofing coating, finished the surface even and smooth without using extra cement including necessary scaffoldings complete upto G+2 Floor Buildings complete all as specified and directed
M&L for two coat of cement base paint over a coat of primer on new plastered surfaces of walls including preparation of surfaces all as specified and directed.
M&L for two coat of white wash on ceiling including preparation of newly plastered surfaces complete all as specified and directed.
M&L for three coat of white wash on walls including preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of primer on walls including preparation of new plastered surface complete all as specified and directed.
Dismantling floor, hearth wall tiling /stone slab/brick tiling /interlocking tiling etc including cement mortar bedding (but not backing)/ cement plaster including rubbish off the premises complete all as specified and directed
Dismantling of old ceiling boards any type and any thickness including cover fillets/ aluminum snap grid complete all as specified and directed
S&F 60 mm thick, machine pressed rubber moulded, glossy coloured, precast conctete interlocking paver block any shape and size of M-35 grade of approved shade laid over 50mm thick sand cushion and joints filled with fine sand complete all as specified and directed.
M&L for 20 mm thick granite for (of any type) machine cut and polished in steps, jambs, pillar window cill, cooking plateform etc laid over and including 20 mm thick screed bed in CM 1:4 , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for hard core using broken bricks of gauge n. exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, water and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in roof kebs or mud stops, rounded or chamfered on edges for exposed to weather and cleaning by wire brushes etc complete all as specified and directed
M&L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed.
M&L for 75 mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregates as in path finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 40mm thick cement concrete type B-1 1:2:4 (20mm graded aggregate) as in floors,finished even & smooth using extra cement including fixing of glass deviding strips complete all as specified and directed. Note:- Glass deviding strips shall be measured and paid seperately as "Supply only".
Supply only glass dividing strips, 3mm thick and 38 mm wide complete all as specified and directed
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) in floor finish rough and even comoplete all as specified and directed
Forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with grade 'A' sealing compound complete all as specified and directed
Demolition of reinforcement cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for RCC 1:1½ :3 type A1(using 20 mm graded stone aggregate) as in foundations, footings, plinth beams; bases for columns, etc.complete all as specified and directed
M&L for RCC 1:1½ :3 type A1(using 20 mm graded stone aggregate) as in Column, pillars, piers, posts and struts etc complete all as specified and directed
M&L for formwork to sides of concrete in foundations, footings, bases of columns, sides and soffits (if any) plinth beams, and similar work complete all as specified and directed
M&L for formwork to sides of concrete of pillars, posts, struts, piers, columns etc complete all as specified and directed
M&L for TMT bars 10 mm dia and over for reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-415 or Fe-500 complete all as specified and directed.
All as per item No 32 above but 5 mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders etc
S&F ACP cladding 3mm thick (overall) with top sheet 0.25mm thick as in wall/ceiling with superior finish, colour and pattern as aproved by GE incliding aluminium framing making grid of size 600mm X 600 mm with aluminium member of size 40mm X 20mm X 1.5mm thick with all fixing arrangement complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc.complete all as specified and directed
M&L for mild steel framed structural work as in doors or gates or cooler stands of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410-0 (Gde-E-250) complete all as specified and directed
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified and directed
M&L for cement concrete 1:3:6 type C2 (40 mm graded stone aggregate) in foundations, filling, surface channels and drains etc. complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in man hole/drain cover slabs and set in CM (1:4) complete all as specified and directed
M&L for 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in gate, wall etc complete all as specified and directed.
Dismantling fencing post of any size and any description complete all as specified and directed
Dismantling of chain link fencing of any description complete all as directed
Excavation in post hole (or similar hole) each n exc 0.50 cum, getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer not exc 25 cm etc and getting out soft/ loose soil complete all as specified and directed
M&L for PCC 1:3:6 type B-1 using 20mm graded stone aggregate as in roof padding, bed plates or mass concrete complete all as specified and directed
S&F for mild steel work as in posts and struts etc in fencing including cutting tops to shapes as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
S&F in repair galvanised two strand steel barbed wire with 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rail strain-ing bolts including, securing or tying at crossing with and provision of galvanised mild steel wire, staplesor steel pins, etc. complete all as specified and directed .
Supply only chain link MS galvanized fencing of any size and any type as approved complete all as specified and directed
Fixing only chain link fencing including line wires, any mess, size and type to any type of standards, rails, straining bolts, etc including provision of binding wires complete all as specified and directed
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc complete all as specified and directed
M&L for two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces including preparation of surfaces complete all as specified and directed
Dismantling of Trellis work (Jafri)/RCC jali complete all as specified and directed
M&L for precast cement concrete type B-O using 12.50 mm graded stone aggregate as in louvers and jallies set in CM 1:4, 35mm thick (measured solid), including all mould- ings but excluding frame complete all as specified and directed
M&L false ceiling with 4 mm thick E-board "Make-Everest" white prelaminated set embossed reinforced designer ceiling board of approved texure fixed with GI imposed grid frame work of size not more than 600 x 600 mm having 24 mm wide T- section, runner made of 0.33 mm GI sheet and angle made of 0.45 mm GI sheet, suspended with 2 mm dia GI wire including two coat of oil bound distemper complete all as specified and directed
S&F PVC SHEET WALL PANELLING of thickness 5 mm consisting of panels of desire size stuck of inner frame work of 50 mm wide strips of 5mm thick prelam PVC sheet. The strip should have in their centre a grove of 6 mm width and 1 mm depth for sinking the head of the screw used to fix the strip to the wall vertically at an equal interval of 10" between two strips. The PVC strips shall be fixed to the wall using 65 mm long MS screw through the groove in the strip by using PVC Fasteners. The distance between two screw shall not be more than 200 mm. A groove of 2 mm may be left at the joint of two paanels for aesthetic looks. The exact size of the panel aand correspondingly of the grid maay vary depending on the size of the wall. Optinally strips of 5mm thick PVC sheet of width 75 mm feathered at the edge shall be stuck t the places where two panels are joined. using solvent cement complete all as specified and directed
S&F in repair 20mm / 25mm bore PVC Coated fancy type curtain rod with fixing brackerts, stops, rollers etc complete allied fitting
S&F in repair 250 mm long Aluminum alloy, anodised sliding door bolts, plate type, ,and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts or extruded sections or cast aluminum alloy complete all as specified and directed
S&F in repair 200 mm long Aluminum anodised barrel tower bolts of extruded section
S&F in repair150mm long alluminium handles, cast type, anodized and fixed complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads (exc 1.5 sqm) complete all as specified and directed
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed
S&F 4 mm thick Sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed
S&F in repair 140 mm floor door stopper of aluminium alloy body and tongue,anodised with hard drawn steel spring complete all as specified and directed
Taking down and refixing in same opening of aluminum door shutter of area exc 1.00 sqm but not exc 2.00 sqm including necessary repair with replacement of rubber beading, and other small articles such as cleats, hinges, screws etc as required complete all as specified and directed
S&F aluminium anodized door with frame of size 100X44.5X 1.5mm, stile, middle and top rails of size 82X44.5X1.5mm thick and bottom rail of size 114X44.5X1.5mm thick including 5.5mm thick tinted glass panes with all fittings/ fixtures such as cleats, tower bolt, hinges, locking arrangement, pull and push handle of aluminium anodized, hydraulic door closer etc., complete including aluminium and rubber beading all as specified and directed.
S&F in repair aluminum (Die cast body) hydraulic door closer regulated designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width complete all as specified and directed
S&F 15mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls/ ceilings/ concealed or laid in floors including taking up or down existing steel tubing and connections complete all as specified and directed
S&F 20 mm tubes medium grade galvanised with all fitting and fixed complete to walls/ ceiling / concealed or laid in floors including taking up or down existing steel tubing and connections complete all as specified and directed
S&F in repair 25 mm dia float valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe with fly nuts complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints complete all as specified and directed.
S&F in repair 110 bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm all as specified and directed.
S&F in repair 15mm dia C P stop valve/angle cock chromium plated with curtch or butterfly handle screwed down, screwed for iron pipe of brass ferrule acomplete all as specified and directed
S&F in repair 15 mm PTMT float valve, high pressure with Polythene floot and flynut complete screwed for Iron pipe etc complete all as specified and directed
Cleaning and removing all scale and dirt, etc from water tanks and from mouths of circulating pipes by following method, etc. capacity of water tank exc. 250 ltrs but not exc 500 ltrs complete all as specified and directed
Dismantling of existing roof treatment of any description and any thickness upto pcc padding complete including removal of debris away from the site complete all as specified and directed
M&L for provn of roof treatment with polymeric water proofing membrance as under including taking down: (a) M&L plastering 10mm in CM 1:4 using 100% course sand on roof including WPC @ 3% by weight of cement. (b) Applying a coat of bitumen primer @ 0.50 Itrs/sqmts and allow to dry. (c ) Applying one coat of hot blown bitumen grade 85/25 @ 1.20Kg/Sqmts.(d) Applying and laying polymeric water proofing membrane weight not less than 3kg/sqmts. (e) Applying a tack coat of hot blown bitumen grade 85/25 @ 1.20kg/sqm and blinding with coarse sand dry @ 0.50 to 1.00 kg/sqm dusted over bitumen.
S&F 40 mm thick brick tiles laid over and including 15mm thick screed bed in cm (1:6) & joint grouted flush in cement mortar (1:3).with WPC as per manufacture's instruction including dismantling brick tiles or terracing tiles, single layer of roofs complete all as specified and directed
All as per item No 78 but except brick tiles all as per specified and directed.
S&F in repair PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of capacity 10 litre ISI marked complete all as specified and directed.
S&F in repair long body bib tap 15mm bore cast copper alloy chromium plated fancy type with crutch or butterfly handle sc-rewed down screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair vitreous china wash hand basin white size 550 x 400mm including brackets complete all as specified and directed.
S&F in repair of aluminium anodised six peg hanger of extraded section & fixed in positions of size 300 mm long as approved by GE complete all as specified and directed.
S&F in repair 15 mm bore dia pillar taps fancy type cast copper alloy with capstan heads chromium plated screwed down hidh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed
S&F in repair 32mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement complete all as specified and directed.
S&F in repair 32 mm bore Low density PVC flexible pipe for wash hand basin/sink etc complete all as specified and directed.
S&F 32 mm bore Low density polyethylene pipes for urinal etc complete all as specified and directed.
M&L for preparation of old decorated plastered or un-plastered surface of walls, cornices, pilasters etc by brooming down scraping, filling all the nail holes etc and prepairing surface with plaster of paris etc and applying one coat of white wash on walls complete all as specified and directed.
M&L for preparation of old decorated plastered or un-plastered surface of walls, cornices, pilasters etc by brooming down scraping, filling all the nail holes etc and prepairing surface with plaster of paris etc and applying one coat of white wash on ceiling mixed with adequate qty of fevicol complete all as specified and directed.
M&L for preparation of old decorated surface of walls, cornices, pilasters etc by washing rubbing down and stopping old distempered and painted surfaces and applying one coat of oil bound distemper on walls, cornice, pilasters etc complete all as specified and directed.
All as per item No. 91 above but applying two coats coat of oil bound distemper (OBD) on wall surfaces.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efforescent salts, trading oil, greasy sopts etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 2-3mm thick white wall care putty (make: Biral/JK/Asian) on walls all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
M&L for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per item No 97 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.
All as per item No 97 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.
All as per Item No 97 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board.
S&F switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
S&F switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
S&F electronic ceiling fan regulator with rotary step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete all as specified & directed.
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
S&F in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC,philips cat no TMC 100 1xT LED /MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen as approved by GE.
S&F in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into existing T8 conventional fluorescent tube light fitting after changing the necessary electric connections as required at site complete all as specified and directed. Make : Crompton, Cat No : LT8-20-865-2 , Havells, Cat No : PHOTONULTRA1213T8SSTL20WLED865SPC/ PHILIPS Cat no MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen as approved by GE.
S&F LED security light fitting 45 watt, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G. I. tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed. Make:- Havells Cat No:- ENDURAPEARLNEOSL45WLED757SASYTOPC or equivalent in Crompton/ Philips as approved by GE.
S&F ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
M&L for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
M&L for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
S&F in replacement of MCB, SP, AC, 240 volt of 06 to 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :-Legrand, Cat No. 4085 87 to 4085 95 or Hager, Cat No : NCN106N to NCN132N or Schneider, Cat No : A9N1P06C to A9N1P32C as approved by GE.
S&F in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :-Legrand, Cat No. 4086 36 or Hager, Cat No : NCN232N or Schneider, Cat No : A9N2P32C as approved by GE.
S&F LED bulb 9/10 W B22 CDL complete all as specified and directed. Make:- Polycab/Havells/Surya/Crompton/Panasonic
Taking down ceiling fan/Exhaust fan any size any make, sealing cable ends, dismantling blades in case of ceiling fan and removing fan and blades to E/M store yard for repair & hanging/fixing of the same after repair and connecting up complete all as specified and directed
M&L in replacement of ball bearing of size 6201/6202/6203 as required, all as specified & directed. Make - NBC/TATA/SKF
S&F in replacement of Capacitor 2.5 Mfd in ceiling fan of any size, exhaust fan of size 300/230mmsize and cabin fan of 400mm sweep, all as specified and directed. Make- Epcos/Usha
Rewinding of Ceiling fan of 1200 mm Sweep comprising of followings: (a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly. (b) Replacement of defective worn out bush where required, (ball bearing, capacitor will be measured and paid separately). (c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new twisted twin core flexible copper cable of size 23/0.0076 of 1 Mtr length. (d) Testing of repaired fan shall be carried out in the yard of AGE E/M (East) to the entire satisfaction complete all as specified and directed.
All as per item No 118 but Exhaust fan 450 mm (18”)
All as per item No 118 but Exhaust fan 380 mm (15”) Sweep.
All as per item No 118 but Cabin fan 400 mm Sweep .
G D SINGH AND CO
QUALITY CONSTRUCTIONS CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .