| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.0 L+₹12,729 (0.58%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹22.4 L+₹52,372 (2.40%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹22.6 L+₹72,292.60 (3.31%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹24.9 L+₹3.0 L (13.7%)Rejected-Finance SANTOKH VILA 81 1ST FLOOR PHASE XI MOHALI PUNJAB 160082 | 160082 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹23.9 L
EMD Value
₹47,760
Closing Date
20 May 2022, 6:00 pmClosed
GE PANAJI
Garrison Engineer S V Road Panaji, Goa PIN - 403001
SPECIAL REPAIR TO BLDG NO P 5 MT GARRAGE REPAIR BAY AT BDE LINE PANAJI UNDER GE PANAJI GOA
2022_MES_519437_1
8922/E8
Open Tender
Civil Works
Item Rate
180 days
GE PANAJI
As per tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER PANAJI
₹47,760
Yes
2 Jul 2022
22 Apr 2022
23 May 2022
22 Apr 2022
20 May 2022
6 May 2022
22 Apr 2022 - 27 Apr 2022
Amount
Dismantling asbestos cement (corrugated/semi corrugated etc) sheet in roof covering and ridges (corrugated/ semi-corrugated) complete all as specified and as directed.
Supply & Fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having Tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Ditto all as item 2 above but plain steel sheet 0.50 mm thick.
Supply & Fix rolled mild steel Fe 410-W (Gde-E-250 quality A) in joist, channel, angle, or tee sections, fixed independently as in rafter and purlins without connecting plates, etc screws complete all as specified and directed.
Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description, over 10cm in width or girth complete all as specified and directed.
Material and labour for applying two coats of synthetic enamel paint including preparation of old steel surfaces of any description, over 10cm in width or girth complete all as specified and directed.
Taking down cement plaster of any description from brick or stone walls including racking out joint hacking for key, scrubbing down with water etc complete all as specified and directed.
Material & Labour for rendering 15mm thick on brick masonry surface or other than fair surface of brick surface in cement mortor 1:4 to be finished even and fair without using extra cement complete all as specified and directed.
Material & Labour for preparation of new plastere surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489-2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over 3mm thick wall care putty on new surface complete all as specified and directed.
Material & Labour rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing in CM 1:6 without using extra cement and finished the furface even and smooth smooth without using extra cement complete all as specified and as directed.
Material & Labour for complete removal of existing treatment and applying two coat of oil emulsion distemper over 3 mm thick wall care putty on plastered surfaces of walls including prepartion of old surfaces complete all as specified and as directed.
Demolition of brick work or stone/boulder masonary, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facing dressed stonework and precast concrete articles complete all as specified and directed by Engineer in charge.
Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed.
Material & Labour for applying two coat of oil emulsion distemper over 3mm thick wall care putty on plastered surface of wall including preparation of new surface of wall complete all as specified and directed.
Supply & Fix aluminum alloy wire mesh 0.45 mm nominal dia of wire and avge width of aperture 1.4mm cut to size and fixed to doors/window shutters and fixed with aluminium wire stapels complete all as specified and directed.
Supply & Fix sheet glass ordinary quality, 4mm thick and glazing with oil putty/wooden beads in squares not exceeding 0.50 sqm each pane complete all as specified and as directed.
Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS:733 and IS 1285 fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions i e at top bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth rust free straight mitred and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing/panelling C P brass/stainless steel screws all complete as per architectural drwings and as specified and directed. Note for Ser item No 17 & 18:- (a) Sheet glass & wire mesh shall be measured & paid separately. (b) Weight of aluminium shall be measured exclusive of all fittings feature hinges, handle bolts and locking arrangement. (c) Weight of the rubber gasket/ beading will not be measured with weight of aluminium section.
Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required with extrtuded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixing with dash fasteners of required dia and size including necessary filling up the gap at junctions ie at top bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/ panelling, C P brass/stainless steel screws all complete as per architectural drwaings and as specified and directed.
Supply and fix anodised aluminium grill (anodised transparent or dyed to required shade according to IS 1856 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement complete all as specified and directed.
Taking down chowkat/ frame with shutters n exc 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and directed.
All as in item No. 20 above but exc 1.5 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Material & Labour 2nd class hard wood for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Supply & Fix 35mm thick (Factory made) 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12mm veneered particle board with commercial veneering on obth faces. The size of rail and stile as per IS 1003 (Part -I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Material & Labour for preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Supply & Fix extruded aluminium anodised, fabricaated type handle, 125mm long complete all as specified and directed.
Supply & Fix 100mm long mild steel butt hinges medium weight, cold rolled mild steel complete all as specified and directed.
Supply & Fix aluminium powder coated barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
Supply & Fix Aluminium alloy powder coated sliding door bolt 300 mm long with hasp & staple (bolt type) and fixing clips of sheet cast of extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
Supply and fix anodized aluminium snap grid frame work for false ceiling of grid size 605mm x 605mm with size of main tee 35mm x 25mm x 1.5mm and cross tee 25mm x 25mm x 1.5mm and supporting angle at the end all alonge the wall 40mm x 25mm x 2mm, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including 6mm thick designer non-asbestos fibre cement building boards fixed or laid/ inserted to aluminium frame work with screws with and including applying two coats of white wash including preparation of new surface of ceiling complete all as specified directed.
Supply only integral water proofing compound (ISI Mark) complete all as specified and as directed.
Supply & Fix perforated rectangular heavy duty precast RCC concrete (M-30) drain covers of size 900mmx450mmx75mm fixed over storm drains, trench drains etc., complete all as specified and directed by Engineer-in-Charge. Note:- The construction work is at any place in camp area, accessible road is not their material is to be carried by manually or mechanically, contractor quoted rates are deemed to be inclusive of this aspects.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) of plinth protection & foot path complete all as specified and directed.
Material & Labour 25mm thick plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, finishing the surface even and smooth as in floor complete all as specified and directed.
Material & Labour coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with over and including 20mm thick screed bed in CM 1:6 complete all as specified and as directed.
Material & Labour 75mm thick plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate, finishing the surface even and smooth without using extra cement as in sub base complete all as specified and directed.
Material & Labour 75mm thick plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate, finishing the surface even and fair without using extra cement as in sub base complete all as specified and directed.
Material & Labour Chequered cement concrete tiles 20cm x 20cm x 25mm thick set laid over and including screed bed 20mm thick in cement mortar 1:6 jointed & pointed in neat cement slurry in floor with grey cement and pigment complete all as specified and directed.
Removing demolished material exc. 1.50 km but n exc. 5 km and depositing where directed the starting point complete all as specified and as directed.
Supply & Fix Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt n exc 4 kg per sqm complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring of light, fan socket 5/15A or power point complete including fittings such as switches, bell push, electric bell, ceiling rose, pendant, regulator, socket, lamp holders, brackets, lamp fittings, tube light fittings etc including switch boards and making good distrubed surfaces of wall/ ceiling etc so as to match with the existing wall/ ceiling/ floors etc complete all as specified and as directed.
Taking down carefully sub main wiring including copper/aluminium/GI earth continuity conductor and making good disturbed surfaces any sizes complete all as specified and as directed.
Taking down MCB DBs with MCBs of any size and capacty alongwith teakwood boards, energy meter incl all fittings/ fixtures carefully and making good disturbed surfaces of wall complete all as specified and directed. Note:- Energy meter is the property of the department and will be kept in safe custody for re-fixing or deposit in MES store.
Fixing only, electric meters retrieved from item No 42 above including connecting and testing complete all as specified and directed.
Material & Labour submain wiring with two runs of single core PVC insulated FRLS, unshethed, 1100 Volts grade, multistranded copper conductor cable of size 4 sqmm (Make: Havells/ Plaza/ Finolex/ Polycab) drawn through and including heavy grade PVC casing N capping. (Make: Prestoplast/ Pressfit/ Finolex/ Precision) of suitable size, in wall/ ceiling including all accessories/ fittings with one run of 4 Sqmm PVC insulated FRLS, unshethed multistranded copper conductor cable as a continuous earth wire complete all as specified. Note:- (a) Two runs of 4 Sqmm single core copper cables and One run of earth conductor cable of 4 Sqmm with and including casing-n- capping will be measured and paid as one unit length.
Material and labour for point wiring with proper colour coding for one light point controlled by one switch complete with 1100Volts grade 1.50 Sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable (Make: Anchor/ Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including heavy grade white/ Ivory colour PVC casing-n-capping of suitable size (Make: Prestoplast/ Pressfit/ Finolex/ Precision) as required at site, on walls/ floors/ ceiling and sunk terminal boxes factory made of 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/ cup washers, for mounting switches, sockets, fan regulators etc. with and including one run of 1100Volts grade, 1.50 sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable as earth continuity wire connected to metallic bodies of luminaries/ Fans etc at one end and connecting to common earth at other end and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed.
All as per ser item No 45 above but for one ceiling fan, point controlled by one switch.
All as per ser item No 45 above but for one exhaust fan, point controlled by one switch.
All as per ser item No 45 above but for one 5Amp independent socket point controlled by one switch.
All as per ser item No 45 above but for one 5A socket point controlled by one switch on same board
Material and labour for point wiring with proper colour coding for 15Amp independent socket point controlled by one switch complete with 1100Volts grade 2.50 Sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable (Make: Anchor/ Havells/ Plaza/ Finolex/ Polycab) fixed/ drawn through and including heavy grade white/ Ivory PVC casing-n-capping of suitable size (Make: Prestoplast/ Pressfit/ Finolex/ Precision) as required at site, on walls/ floors/ ceiling and sunk terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/ cup washers, for mounting switches, sockets etc. with and including one run of 1100Volts grade, 2.5 sqmm PVC insulated unsheathed multistranded FRLS grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed.
Material & Labour for switch Piano flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified. (Make : Anchor (Delux)/ Leader/ Bajaj)
Material & Labour for socket outlet 5 pin, 5 Amps flush type white finish complete all as specified. (Make : Anchor (Delux)/ Leader/ Bajaj).
Supply & Fix switch socket combination 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified. (Make : Anchor (Delux)/ Leader/ Bajaj).
Supply & Fix ceiling rose, surface backlite, 65 x 20 mm three terminal fixed on PVC block complete all as specified and directed. Make: Anchor (Delux)/ Leader/ Bajaj.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make: Havells/ Bajaj/ Wipro.
Supply and Fixing exhaust fan, double ball bearing, ISI marked, metal body 380 mm sweep, single phase, 230 Volt AC, with louvers, including three core flexible cable of required length of size 23/0.0076 from ceiling rose/ connector to fan terminal including nut, bolt fixed on wall and all other accessories required at site and necessary cutting on wall and making good as per the requirement all as specified and directed. Make : Bajaj / Havells /Usha
Supply & Fix electronic socket size, rotary, 5 speed step type regulator, 220-230 volt white finish complete all as specified. Make: Crompton greaves/ Bajaj/ Anchor.
Supply and fix double door metallic sheet metal enclosure SPN DB 4 way, 240 Volts with 200Amps rated bus bar complete fixed properly on/ in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed. Make:- Havell’s/ Schneider/ L&T
All as per ser item No 58 above but 8 way.
Supply and fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single poles & Neutral (SPN) and current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. Make:- Havells/ Schneider/ L&T
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. Make:- Havells/ Schneider/ L&T
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of four poles and current carrying capacity TPN 63 Amps in the DB complete with connection testing and commissioning complete all as specified and as directed. Make:- Havells/ Schneider/ L&T
Supply and fix MCB DB Vertical load line double door vertical DB 4 way TPN 415 volts 3 phase with suitable bus bar rating and including MCCB of 100 Amps as incommer all prewired with neutral and earth links flushed to wall and testing including taking down old unserviceable MCB DB vertical type including all fixing accessories in any position and location carefully after disconnection of all electrical connections and making good the disturbed surfaces complete all as specified and directed. Make : Havells/ Schneider/ L&T
Taking down old ceiling fan, of any size including louvers in any position including re-fixing where directed with provision of 3 core flexible cable of suitable size and new down rod of suitable size and length where required and testing after completion all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below natural ground level) with top edge of plate not less than 1.5m below normal ground level, connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I, connecting to main switch board/ main DB’s earthing test point all as specified or indicated including necessary earth work/excavation in any type of strata, adequate quantity of charcoal dust and common salt, provision of PCC 1:3:6, type C-1 using 20mm graded crushed stone aggregate as in foundation and wall of earth pit, RCC 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in cover slab 50mm thick with 6mm dia MS bar @ 100mm c/c both ways with suitable lifting handle, charcoal dust and common salt mixed and packed in 150mm thick layer all around the earth plate, funnel with watering pipe GI light grade 20mm dia, 0.63mm thick GI sheet funnel with wire mesh and copper lugs etc.and lead protection pipe GI light grade 15mm dia up to 7.5metre from electrode and engraving of earth marking on nearby structure/building with cement motor 1:4 plate of size 200mm x 150mm x 15mm thick and writing of earth results with paint complete including testing after completion complete all as specified and as directed. Note :- On testing if desired earth resistance is not obtained earthing will be re-done on no extra cost.
Supply and fix security light fitting LED 20W New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impact resistance of IK07 complete all as specified and as directed. Make:- Havells Cat part No: ENDURAPEARLSL20WLED757SASYT OPCMP or equivalent in Phillips/ Bajaj/ Wipro/ Crompton.
Material & Labour for bracket made out of GI pipe 25mm dia medium grade, 60cms long bent to shape with MS flat iron clamps made out of 40mmX 6mm thick FI nuts, bolts complete all as directed by Engr-in-Charge.
BAJARANG SWAMANISH
N VENKATESWARLU
M/s Jeet Construction
chahalbuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .