| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹40.8 L+₹1.3 L (3.41%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹40.9 L+₹1.5 L (3.77%)Rejected-Finance | L3 | Rejected-Finance Higher bid value |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
REPAIR MAINT OF UNSV SERVO CONTROLLED VOLTAGE STABILIZER AND CONSTANT CURRENT REGULATOR AND REPAIR MAINT PEIODICALS SERVICES REWIRING PAINTING AT VARIOUS DG SETS INSTALLATION AT RMS
2022_MES_558863_1
8504/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
RANGAPAHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE 868 EWS
₹77,000
4 Feb 2023
20 Oct 2022
21 Nov 2022
20 Oct 2022
19 Nov 2022
7 Nov 2022
20 Oct 2022 - 5 Nov 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation of poles, cables etc, not exc 10 sqm on plan and getting out in soft/ loose soil including taking out brick protection etc. complete all as specified
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed.
Removing of excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed.
M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: For measurement purpose, punned down thickness shall only be taken.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
Supply and fixing galvanised iron tubing 40 mm bore, light grade with all fittings for passing of under ground cable including taking down old pipe complete all as specified and as directed.Make:- Jindal/TATA/Prakashsurya
All as per item No 6 here-in-before but 50mm bore
Dismantling the servo volatge satbiliser in position upto capacity 250 KVA and lifting of core from the stabiliser for identification of fault and reassembling after rectification of fault. Note:- Spares reqd for replacement shall be paid under the respective item as under.
S & F in replacement of push button swich /DPDT switchand making electrical connection complete all as specified and as directed.
S & F in replacement of auto manual switch and making electrical connection complete all as specified and as directed.
S & F in replacement of Micro switch and making electrical connection complete all as specified and as directed.
S & F in replacement of potentiometer and making electrical connection complete all as specified and as directed.
S & F in replacement of defective electronic circuit card (PCB) and making electrical connection complete all as specified and as directed.
S & F in replacement of defective microproccessor based control card for each phase and making electrical connection complete all as specified and as directed.
S & F in replacement of defective trigger transformer and making electrical connection complete all as specified and as directed.
S & F in replacement of defective servo motor 3 Kg torque and making electrical connection complete all as specified and as directed.
All as per item No 18 here-in-before but 10 Kg torque
S & F in replacement of RC network for servo motor 3 Kg torque and making electrical connection complete all as specified and as directed.
All as per item No 20 here-in-before but 10 Kg torque
S & F in replacement of unserviceable carbon brush suitable for servo voltage stabiliser upto 250 KVA cap and making all electrical connections complete all as specified and as directed.
S & F in replacement of Dimmerstat 50 KVA cap 28-35 amps current rating and making electrical connection complete .
All as per item No 23 here-in-before but dimmerstat cap 75 -100 KVA 40-50 amps current rating .
All as per item No 23 here-in-before but dimmerstst cap 150 KVA 100-120 amps current rating .
Repalcement of main transformer 75 KVA cap and making electrical connection complete .
Draining out of unsv transformer oil from stabiliser and M&L for new transformer oil strength not less than 40 KV at 4mm gap.
Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core incl taking out old unsv cable from trenches all as specified and as directed. Make:- Plaza/Havells/Finolex
All as per item No 28 here-in-before but 50 sqmm 3.5 core size.
All as per item No 28 here-in-before but 70 sqmm 3.5 core size.
Taking down LT UG cable/ service connection M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 4 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
All as per item No 31 here-in-before but of size 95 sqmm 3.5C
All as per item No 31 here-in-before but of size 120 sqmm 3.5C
All as per item No 31 here-in-before but of size 185 sqmm 3.5C
M&L for replacement of heat shrinkable end termination cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size 50 Sqmm 3.5 core 1100 Volts garde for indoor/outdoor use complete with jointing materials and accessories. Make:- Raychem/3M/Densons
All as per item No 35 here-in-before but electric cable of size 70 sqmm 3.5 core
All as per item No 35 here-in-before but electric cable of size 95 sqmm 3.5 core
All as per item No 35 here-in-before but electric cable of size 120 sqmm 3.5 core
M&L for replacement of heat shrinkable straight through cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size 50 Sqmm 3.5 core 1100 Volts garde for indoor/outdoor use complete with jointing materials and accessories. Make:- Raychem/3M/Densons
All as per item No 39 here-in-before but electric cable of size 70 sqmm 3.5 core
All as per item No 39 here-in-before but electric cable of size 95 sqmm 3.5 core
All as per item No 39 here-in-before but electric cable of size 120 sqmm 3.5 core
Material and labour for repairing the existing earhting pit including RCC cover and making good the damaged portion complete all as specified and directed
S&F in replacement change over switch on load type 400 Amp 4 pole fix to wall/LT panels with the help of metal fasteners and electrical connections complete all as specified and directed. Make: Havels/Indoasian/standard
All as per item No 44 here-in-before but of 315 Amp 4 pole
All as per item No 44 here-in-before but of 200 Amps 4 pole
M& L for replacement of Cable lugs with aluminium alloy tubular bimetallic terminals of size 25/35 Sqmm incl crimping with help of crimping tools all as specified and directed Make :- Dowells/Jainsons or equivalent
All as per item No 47 here-in-before but of size 50/70 sqmm
All as per item No 47 here-in-before but of size 95/120 sqmm
All as per item No 47 here-in-before but of size 150/185 sqmm
M&L for PVC/XLPE insulated twin core aluminum stranded conductor round/flat cable size 10 Sqmm 1100 Volts grade served with an sheathing of PVC tape and overall PVC sheathed in service connection incl taking down old unsv cable.
All as item No 51 here-in-before but 16 Sqmm
Material and Labour for Earthing complete with galvanized steel earth plate 60cm x 60cmx6mm thick electrode, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of earth plate at a depth not less than 1.5 mtrs below normal ground level, connected to GI wire 4mm size up to test point by means of nuts, bults, check nuts and washers of GI including excavation and earth work, PCC (1:3:6) type C1 pit 20mm dia GI pipe, medium grade watering pipe and 15 mm bore GI pipe, light grade for protection of earth wire, 50mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 15cm C/C both ways and with handle made out of 10mm dia bars, funnel, wire mesh etc complete as shown in electrical Plate No 03 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed
All as per item No 53 here-in-before but using galvanised iron strip 32x6mm as earthing lead.
M&L Earth continuity conductor buried in ground and wall surfaces for loop earthing etc. as required 32 x 6 mm Galvanised iron strip
Supply and Fixing of MCCB, 4 pole, 400 Amps, 415 V, 36 KA breaking capacity, thermal magnetic release type including taking down old one complete all as specified and directed .Make: ABB/Legrand/Schneider.
All as per item No 56 here-in-before but MCCB, 250 amps 4 pole.
All as per item No 56 here-in-before but MCCB, 200 amps 4 pole.
All as per item No 56 here-in-before MCCB, 160 Amps 4 pole ,
All as per item No 56 here-in-before but MCCB, 125 Amps, 3 pole 16KA
Preparation of old painted surfaces of voltage stabiliser/LT panel board after scraping existing painted surfaces and priming with one coat of red oxide over two coats synthetic enamel colored as approved by engr -in - charge and GE all a specified. Make of paint:- Berger/Asian
Repair and Maint of Becan light by providing service engineer including repairing/replacing of defective parts of becan light by identifying the fault, replacement of defective lights, carbon brush and and other components and servicing the same, including calibration of becan light and complete checking servicing each. complete all as directed .
Repair/maint of LT panel board by dismantling all cable connection i.e incoming and outgoings and trenching out of loop of cable by digging, cutting burnt portion of cable, cleaning and fixing of lugs with crimping tool, cleaning of bus bar with emery paper, tightening of bus bar with busbar insulators, re-fixing of cable with busbars, by providing new bolts, nuts and washers cable lugs to be provided for all incoming and outgoing cables all as specified and as directed.
Repair/Maint of Thyristor type NASU system (Make: CCR ) by providing OEM service engineer including repairing/replacing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and servicing the same, including calibration of CCR and complete checking servicing Thyristor type NASU capacity 4KW each. Nos of Units=06 Nos, complete all as directed . Note: (i) Maint of CCR will be carried out quarterly. (ii) Each CCR test will be carried out and calibration report will be submitted to department. (iii) All the components reqd for servicing and to make ther CCR serviceable shall be provided by the contractor and measured separately.. (iv) The CCR shall be calibrated and serviced by OEMs Rep/ his auth rep only.
Supply and Fixing Main contract card including RMS to DC converter card and taking out unsv card complete all a specified. .
Fixing only Over current trip and taking out unsv card complete all a specified. .
Supply and Fixing Relay card-02 Nos and taking out unsv card complete all a specified. .
Supply and Fixing TTM card and taking out unsv card complete all a specified.
Supply and Fixing 24 Volt DC plug in type relay and taking out unsv relay complete all a specified. .
Supply and Fixing 48 volt DC plug in type relay suitable for 11 pin socket and taking out unsv relay complete all a specified. .
Supply and Fixing 240 volt AC plug in type relay and taking out unsv relay complete all a specified. .
Supply and Fixing of thyristor H 65 TB 15 and taking out unsv part complete all a specified. .
Supply and Fixing HRC fuse link 32 Amps Set of 02 Nos and taking out unsv fuse complete all a specified. .
Supply and Fixing HRC fuse link 4 Amp and taking out unsv fuse complete all a specified. .
Supply and Fixing 02 pole 8 way brilliancy switch Rotary , MB type and taking out unsv switch complete all as specified. .
Supply and Fixing Power transistors MJ 11016 (Set of 02 Nos) and taking out unsv part complete all a specified. .
Supply and Fixing 30 Amp conductor (Mode: 3TF33) suitable for 4Kwh NASU and taking out unsv part complete all a specified. .
M/s K P Enterprises
das enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .