| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.8 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹3.9 L+₹2,867 (0.75%)Rejected-Finance | 2 | Rejected-Finance 2 | |
| 3 | 3₹4.0 L+₹15,631 (4.06%)Rejected-Finance 0 KALAMBAGH CHOWK MUZAFFARPUR BIHAR 842002 UDYAM BR 23 0013096 | MUZAFFARPUR | BIHAR | 842002 | 3 | Rejected-Finance 3 | |
| 4 | 4₹4.1 L+₹20,646 (5.37%)Rejected-Finance 2817 20 GURU NANK AUTO MKT KASHMERI GATE DELHI 6 | 4 | Rejected-Finance 4 |
Tender Value
₹4.9 L
EMD Value
₹9,875
Closing Date
16 Mar 2023, 11:00 amClosed
EEE/KPZ
EEE/KPZ
Provision of Semi High Mast Poles with lights in B4, keshavpuram near Maharana Pratap Bhawan and A1 Block keshavpuram Market in ward No. 75 Under KP Zone
2023_NDMC_148535_1
TC/ENGG./EEE/KPZ/2022-23/10.3
Open Tender
Electrical Works
Item Rate
60 days
EEE/KPZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹9,875
21 Nov 2024
10 Mar 2023
17 Mar 2023
10 Mar 2023
16 Mar 2023
10 Mar 2023
Amount
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
14.15.1:Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
OD2097/2022-2023:Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X6 Sq. mm.
OD3068/2022-2023:"Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal).
OD2098/2022-2023:Fabrication, Supplying, Installation, testing, Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside & out sides & suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame, 2 point suspension system with steel wire rope 5mm dia. (7/19 construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial, the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. depth with all material i/c 4Nos S.P MCB, 63Amp. DP Isolator etc as reqd. Logo/Name of Manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
OD2099/2022-2023:"SITC of 150 Watt LED flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover i/c mounting bracket complete with the following specification as reqd. Total SYstem Wattage - 150Watt+ -5% Luminaire Efficacy>=100 Lm/w Power Factor>=0.95 Protection level - IP66"
OD3069/2022-2023:"Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS. 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick "
OD3070/2022-2023:SITC of 60W LED Street Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd. (b) Total system wattage =60 watt +/- 5% (d) Luminaire Efficacy>=100 Lm/w (e) Power Factor>=0.95 (f) Protection Class- IP-66
OD3071/2022-2023:Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap and 250 mm long 32 mm dia galvanized pipe with tightening bolts complete as required.
OD3072/2022-2023:Providing and laying in position 1:2:4 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DCW HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
OD3073/2022-2023:P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core cable confirming to IS.647/1990 etc. as reqd. 3x2.5sqmm
OD2100/2022-2023:Providing and Fixing name board made of MS Sheet 90x60 cm , 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embeded in CC block 1:2:4(1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying primary coat of approved steel primer, painting with synthetic enamel point of approved quality and lettering with enamel paint of approved colour (one side) as per drawing /direction of Engineer in charge.
OD2101/2022-2023:Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
OD2102/2022-2023:Providing and fixing stainless steel ( Grade 304) plate made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the plate with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in? charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
OD2103/2022-2023:Lettering with black Japan paint of approved brand and manufacture
14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
Kamal Electricals
Naman Enterprises
KHANNA SALES CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .