Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.5 L+₹1.9 L (5.06%)Rejected-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹40.8 L+₹4.2 L (11.3%)Rejected-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-AOC Other than L1 | |
| 4 | Rejected-Technical MOH SWAMI PADAM JAHANGIRPUR GREATER NOIDA GAUTAM BUDH NAGAR UP 203141 | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | 203141 | - | Rejected-Technical Not Recommended due to DD not found in favour of GE (W) Mathura as per NIT |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
17 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mathews M Shepherd, GE
GE (W) Mathura
SPECIAL REPAIR FOR REPLACEMENT OF COOLING APPLIANCES AGAINST BER AND SPECIAL REPAIR TO DEVELOPMENT OF OLD VINTAGE RADIAL WELL WITH ALLIED SERVICES, VT PUMP/COLUMN PIPES TO IMPROVE THE WATER YIELD UNDER GE(WEST) MATHURA
2022_MES_568499_1
8300/1107/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) MATHURA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹84,000
Yes
23 Feb 2023
20 Dec 2022
24 Jan 2023
20 Dec 2022
17 Jan 2023
4 Jan 2023
Amount
Supply, installation and testing Window AC complete with cordless remote control remote unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.45 of capacity 1.5 Ton, noise level not more than 49 DB complete all as specified and as directed.
Supply, installation and testing of hi wall split unit indoor/outdoor complete with cordless remote control unit and with inbuilt air ionizer and plasma filter for better indoor air quality, PM 1.0 filter, invertor compressor, turbo cooling, dew clean technology, tripple display, automatic moisture adjustment, fast cooling, streamer discharge, high ambient operation uotp 54 degree celcious with minimum 5.0 star rating and ISEER 5.2 of cooling capacity 1.5 Ton (not less than 5250 Watt) complete all as specified and as directed.
Supply, installation, commissioning of water cooler fully stainless steel, electric driven single phase having storage 80 ltrs and nominal cooling capacity 40 ltrs per hour complete all as specified and directed.
Supply, installation and testing of refrigerator electric driven single phase 240 Volts capacity 195 Ltr BEE 5 star rated single door complete all as specified and as directed.
Supply, installation and testing of refrigerator electric driven single phase 240 Volts capacity 310 Ltr BEE 5 star rated double door complete all as specified and as directed.
S&F voltage stabilizer for automatic operation single phase naturally air cooled in door type & designed for input variation between 130 Volts to 300 Volts with output voltage stabilzer at 230 Volts with accuracy of (+/-) 2.5% and speed of correction 8 volts per second of capacity 5 KVA with and including connected accessories complete all as specified and directed.
S&F voltage stabilizer for automatic operation single phase naturally air cooled in door type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilzer at 230 Volts with accuracy of (+/-) 2.5% and speed of correction 8 volts per second of capacity 3 KVA with and including connected accessories complete all as specified and directed.
Labour and T&P for desilting of Radial well manually and removing silt/sand from not more than 40 mtr depth from the bottom slab and removed/disposed off to a distance of exc 250mtr but n. exc 500mtr , turning ON/OFF water without damage of existing plant and machinery as per time requirement and as directed by Engineer-in-Charge. Note:Contractor will arrange Desilting pump and all T&P as required on site to complete the work.
M&L for cleaning the Radial pipe of 300 mm dia max length upto 50 metre diagonally by Air Pressure Jet and cleaning the existing radial pipe without damaging the same complete all as specified and directed. Note: The work will carried out inside well/Radial well at the depth upto 40Mtr.
Taking out old unserviceable NRV of size 200 mm dia and S&F NRV 200mm dia CI body including nuts, bolts washers complete all as specified and directed.
M&L for water pressure gauge of size 100 mm dia including drilling of pipe line of size 200 mm dia for fixing the water pressure gauge complete all as specified and directed.
Taking out old unserviceable Air release Valve of size 100 mm dia and S&F Air Release Valve 100 mm dia CI body including nuts, bolts washers complete all as specified and directed.
M&L for MS work to support over bridge base guarder by fabricated from structural steel plate 6mm thick sections including welding, bending cold or hot drilling holes in any shape and size as directed or indicated including two coats of enameled paint after one coat red oxide promer all as specified and directed. Note : Old material will not be retrieved due to additional support to base guarder of over bridge path.
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion. Note: (i) Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc. complete all as specified and directed. (ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.
M&L for in repair /replacement of Earth continuity conductor of size 25x4 mm galvanised iron strip complete all as specified and directed.
Supply and replacement of thrust bearing (cat No 29324E,Make:SKF) suitable for vertical type hollow shaft induction motor of capacity 75 HP including lubricating oil 20W40 complete all as specified and directed.
Supply and replacement of ball bearing (cat No 6316,Make:SKF) suitable for vertical type hollow shaft induction motor of capacity 75 HP including grease all as specified and directed by Engineer-in-Charge.
Supply and laying LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. complete all as specified and directed.
Supply and laying LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core. complete all as specified and directed.
M&L and T&P for removing of old paint from Motor of capacity 75 HP,Starter,discharge head,sluice valve &NRV and painting the same with two coats of synthetic enamelled paint as existing colour over a coat of red oxide primer complete all as specified and directed.
M&L and T&P for removing of old paint from OT crane alongwith panel board and accessories with chain pully block ,servicing and greasing complete crane with chain pully block and painting the same with two coats of synthetic enamelled paint as existing colour over a coat of red oxide primer complete all as specified and directed.
Taking down the sign board of Radial Well, removing the old letters,repair of lights,Painting of board and writing the letters "RADIAL WELL GE(W) MATHURA"as per existing size and refitting the same complete all as specified & directed.
S&F MS framed work such as grills, cooler stand ,grating, etc., with ends of bars,sections shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 290 Gde E-165 complete including dismantling old framed work all as specified and directed. Note : (a) The work will be carried out below GL in UG sump/Radial Well. (b) The MS work will be fabricated from structural steel sections and required to be fixed by welding or drilling holes in RCC walls into existing framed works by grouting or welding and making good of existing surfaces. (c) The work is meant for 5 mtr dia plateform in redial well below 4.5 mtr depth and replacement of rusted angle iron ladder upto 40 mtr depth as per existing shape and size (d) Painting on MS work will be carried out by applying one coat of Red Oxide primer and two coats of Anti Corrison Paint is deemed to included in the rate quoted by the bidder.
M&L for preparation of old decorated steel surface of bridge member of radial well and applying one coat of aluminium paint over one coat of primer complete all as specified and directed.
M&L for scraping out old paint from rising mains and delivery pipe lines upto 400 mm and preparation of surfaces of pipes by applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for preparation the surface of chequered plate and applying one coat of black japan paint over the surface of cheqiered plate including all tools and arrangement of scaffolding as required at site complete all as specified and directed.
S&F in replacement of LED300 watt energy saving environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light, suitable for highlighting architectural facaade and general purpose lighting with all connected accessories including bolts, nuts, brackets, suitable size of pipes for mounting of Light complete all as specified and directed.
S&F in replacement the existing Digital water level indicator Device having MS Housing made up of CRC sheet box at Radial Well of 150mm Digit display type DDs-6 230V AC+ complete with copper wiring with 4 core 0.5 Sqmm with suitable conduit pipe for upto 40 mtr and alarm for upper and lower preadjustable as per requirement and reset push switch for silent the alarm mode of operation ON/OFF and testing on completion ensure keep the indicator working mode complete all as specified and directed.
M&L for cast iron valve flanged type, iron wheel head screwed class PN 1.6 of size 300 mm including nut, packing etc. complete. Note : (a) The work will be carried out below GL in radial well at the depth 40 mtrs from the bottom slab.
M&L for cast iron sluice valve flanged type,iron wheel head screwed class PN 1.6 of size 150mm including nut, packing etc. complete
Taking out old cast iron sluice valve upto 300 mm dia complete all as directed
Ms Kamal Kant Agarwal
M/s DEVI DAYAL CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .