Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.1 LAccepted-AOC N A | ₹52.1 L | L1 | Accepted-AOC l1 |
| 2 | L2₹54.8 LRejected-Finance | ₹54.8 L | L2 | Rejected-Finance L2rejected |
| Sl No | Description | Qty | Unit | RATHAKRISHNAN R L2 | Rajagopal L1 |
|---|---|---|---|---|---|
| 1.00Construction of Community hall Buildibg at Maniyakaranpatti Village and Panchayat | |||||
| 2.00 | Earthwork excavation and depositing on bank with initial lead and lift in hard gravelly soil for foundation etc. complete. | 118.65 | Cubic meter | 276.97 ₹32,862.49 | 263.67 ₹31,284.45 |
| 3.00 | Cement Concrete 1:4:8 mix using 40mm metal including cost and conveyance of all materials to site and labour charges etc. complete. | 31.74 | Cubic meter | 5,991.27 ₹1.9 L | 5,703.69 ₹1.8 L |
| 4.00 | FlyAsh Brick work in Cement 1:5 mix using country Bricks of size 23x11.5x7.5cms for the following including mixing mortar and all other labour charges etc. complete. | 71.93 | Cubic meter | 7,949.35 ₹5.7 L | 7,567.78 ₹5.4 L |
| 5.00 | Filling with Collected Gravel including all labour charges etc. | 76.72 | Cubic meter | 294.36 ₹22,583.30 | 280.23 ₹21,499.25 |
| 6.00 | Supplying and erecting shttering including necessary support for plane surface in foundation Basement and Roof labs strutting upto 3.29M height for plane surfaces for floors for RCC column footings columns plinth beam and connected with foundations (Below Ground level) | 146.7 | Squre meter | 574.88 ₹84,334.90 | 547.28 ₹80,285.98 |
| 7.00 | Supplying and erecting shttering including necessary support for plane surface in foundation Basement and Roof labs strutting upto 3.29M height for plane surfaces for floors for RCC column footings columns plinth beam and connected with foundations (Above Ground level) | 396.62 | Squre meter | 1,149.75 ₹4.6 L | 1,094.56 ₹4.3 L |
| 8.00 | Supplying, fabricating and placing in position mild steel or ribbed to steel and all reinforced cement concrete works as per the design given including cost of steel and binding wire in all floors etc. complete. | 7.93 | Metric tonne | 96,520.94 ₹7.7 L | 91,887.93 ₹7.3 L |
| 9.00 | RCC 1:1.5:3 using 20mm HBG metal including cost and conveyance of materials and labour charges etc. complete | 72.12 | Cubic meter | 9,917.74 ₹7.2 L | 9,441.69 ₹6.8 L |
| 10.00 | Weathering course with best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be listed) over the RCC roof slab in the proposition being brickjelly to lime 32:12:1/2 by volume and laid over into a single layer and cons | 11.2 | Cubic meter | 4,390.9 ₹49,178.08 | 4,180.14 ₹46,817.57 |
Tender Value
₹53.5 L
EMD Value
₹53,500
Closing Date
10 Feb 2026, 3:00 pmClosed
Joint Director/Project Director(FAC)
DRDA Thoothukudi
Construction of Community Hall Building at Maniyakaranpatti Village and Panchayat at Thoothukudi District Under DMFT Mines 2025-26 Package No TN/TUT-19/2025-26
2026_RDTN_650536_17
RDTUT/370/2025/A13 dated 31.01.26
Open Tender
Civil Works - Buildings
365 days
DRDA THOOTHUKUDI
As per Tender Document
4 documents required · 4 mandatory
₹0
₹53,500
05.02.2026
13 May 2026
4 Feb 2026
10 Feb 2026
4 Feb 2026
10 Feb 2026
4 Feb 2026
5 Feb 2026
Construction of Community hall Buildibg at Maniyakaranpatti Village and Panchayat
Earthwork excavation and depositing on bank with initial lead and lift in hard gravelly soil for foundation etc. complete.
Cement Concrete 1:4:8 mix using 40mm metal including cost and conveyance of all materials to site and labour charges etc. complete.
FlyAsh Brick work in Cement 1:5 mix using country Bricks of size 23x11.5x7.5cms for the following including mixing mortar and all other labour charges etc. complete.
Filling with Collected Gravel including all labour charges etc.
Supplying and erecting shttering including necessary support for plane surface in foundation Basement and Roof labs strutting upto 3.29M height for plane surfaces for floors for RCC column footings columns plinth beam and connected with foundations (Below Ground level)
Supplying and erecting shttering including necessary support for plane surface in foundation Basement and Roof labs strutting upto 3.29M height for plane surfaces for floors for RCC column footings columns plinth beam and connected with foundations (Above Ground level)
Supplying, fabricating and placing in position mild steel or ribbed to steel and all reinforced cement concrete works as per the design given including cost of steel and binding wire in all floors etc. complete.
RCC 1:1.5:3 using 20mm HBG metal including cost and conveyance of materials and labour charges etc. complete
Weathering course with best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be listed) over the RCC roof slab in the proposition being brickjelly to lime 32:12:1/2 by volume and laid over into a single layer and cons
Finishing the top of the roof with one course of Machine PressedTiles of size 23 cm x 2 cm of approved quality laid in CEMENT MORTAR 1:3(One cement and three sand) 12 mm thick mixed with water proofing compound conforming to ISS by 2% weight of cement us including all charges etc.
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete
Dadooing walls with Glazed tiles of any colour and any size laid in CM 1:2, 10mm thick. and pointing with white cement 0.4 Kg per sqm mixed with colouring pigment to siut the colour of the tiles including finishing the joints neatly complete
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty should be got approved by the Executive Engineer before use on work. (Based on SoR 2024-25)
Plastering with CM 1:5 mix 12mm thick including cost and conveyance of all materials to site and labour charges etc. complete.
Distembering two coats with best approved distember including cost and conveyance of all materials to site and all labour charges etc complete
Painting two coats with Interior Emulsion & Exterior Emulsion using best quality of Emulsion, Brushs, scaffolding charges etc. complete
Provision for Cuddapa Slab 40mm thick including all charges etc.
Electrical Arrangements
Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point/Fan Point SD 20
Supply and fixing of fancy glass shade and 15 W LED Bulb SD-80
Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb - SD. 83
Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting SD. 88
Wiring with 2 x 1.5 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x 100 x 113mm TW switch box for 5A 3 pin non inter locking Wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open PVC plug point.- SD -36.
Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1" x 1/8" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection SD 125
Supply and run of 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains (Service pipe) SD-69
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) SD No.144
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp . SD-110
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade on 7/20 GI bearer wire for service connection mains for Service wire - SD.64
Septic Tank
Earth work excavation and depositing on bank with in initial lead of 10 mt and initial lift of 2mt in Hard Gravelly soil for foundation as per specification
Cement Concrete 1:4:8 mix using 40 mm ISS H.B.G. metal including cost and conveyence of all materials to site and all other albour charges etc., completed.
FlyAsh Brick Work in C.M 1:5 mix using good quality of country bricks including cost and conveyence of all materials to site and all other labour charges etc., completed.
Supply and errection of steel centering for all R.C.C items of works including hire charges and labour charges for errection etc., completed.
Supplying and fabrication of steel including cost and conveyence of all materials to site and all other labour charges for straightening ,cutting, bending , placing in position tying etc completed.
Reinforced Cement Concrete 1:1.5:3 mix using 20 mm ISS HBG metal including cost and conveyence of all materials to site and all other labour charges etc., completed.
Plastering with cement mortar 1:5 mix 12mm thick including all cost and conveyance etc., complete.
Plastering with cement mortar 1:3 mix 12mm thick including all cost and conveyance etc., complete.
Supply and filling of 40mm brick jelly including cost and conveyence of all materials to site and all other labour charges etc., completed.
Water Supply and Sanitary Arrangements
Provision for Indian Water Closet including all labour charges etc.
Provision for Water Supply Specials (TWAD Rate)
2000 ltr PVC tank
15mm Tap
Mirror 600 x 450 mm size
110 mm PVC Pipe
110 mm Elbow
110 mm Tee
Wash Basin Colour (560 x 450) Ovel Shape
25 mm PVC Pipes
25 mm Elbow
25 mm Tee
32 mm PVC Pipes
32mm Elbow
32mm Tee
25mm GM Gate Valve
63mm PVC Pipes
63mm Elbow
63mm Tee
50mm GM Gate Valve
Earthwork excavation and depositing on bank with initial lead of 10m and lift of 2m in narrow trenches for laying of pipesin Hard stiff clay, stiff black cotton,hard red earth, shales, murram, gravel, earth mixed with small sized boulders etc...
Laying of PVC 63mm pipes to proper line and level including jointing but excluding cost of pipes
Refilling the excavated earth after laying and joining of pipes including all labour charges etc..complete
Doors, Windows, Ventilator Arrangements
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un- plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. (M-0673)
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work (M-0674)
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work (M-0674)
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
19Pudur.pdf
Tender Documents • 0.82 MB
BOQ_780516.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid