Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹17.8 L+₹17,430.50 (0.99%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Higher rate | |
| 3 | L3₹19.2 L+₹1.5 L (8.46%)Rejected-Finance | L3 | Rejected-Finance Higher rate | |
| 4 | L4₹19.3 L+₹1.6 L (9.03%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-Finance Higher rate | |
| 5 | L5₹19.4 L+₹1.7 L (9.85%)Rejected-Finance | L5 | Rejected-Finance Higher rate |
Tender Value
Refer Docs
EMD Value
₹53,000
Closing Date
27 Feb 2021, 6:00 pmClosed
GE(AF) JAISALMER
GE(AF) JAISALMER
Repair/Maint of Security and Street light and other allied works services at Air Force Station Jaisalmer
2021_MES_421507_1
8707/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE(AF) JAISALMER
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) JAISALMER
₹53,000
Yes
6 Mar 2021
12 Feb 2021
1 Mar 2021
12 Feb 2021
27 Feb 2021
22 Feb 2021
Amount
Pre Stressed concrete Pole 9.00 mtr long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including disconnecting & taking down old unserviceable broken RCC Pole complete all as specified and directed
PVC insulated and fire retardant PVC sheathed, Round, 3 core cable, copper conductor of size 1.5 sqmm for electric connection from feeder /looping box /street light over head line to street light fittings and including taking out old unserviceable cable from pole all as specified and directed.
Street light box of PVC consisting of MCB 10 Amps, 10 KA rupturing capacity (Single Pole) with bakelite TPN supporter and din rail for fixing MCB for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamp and including taking out old unserviceable complete all as specified and directed. Make : Sintex/National/Bajaj.
LED outdoor electronic driver suitable for LED street light fittings for capacity 45 watt suitable and including taking out old unserviceable complete all as specified and directed. Make : Crompton Greaves Cat Part No S0DQL-65-700-45W or equivalent in Philips / Orient /Havells / Wipro as approved by GE.
LED outdoor electronic driver suitable for LED street light fittings for capacity 75 watt suitable and including taking out old unserviceable complete all as specified and directed. Make : Crompton Greaves Cat Part No X075C070V107FNY 1BO or equivalent in Philips / Orient /Havells / Wipro as approved by GE.
Energy efficient LED street light fittings of capacity 60 Watt, Aerodynamically designed street light with excellent thermal management in built tilt angle arrangement with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 5 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections and including taking out old unserviceable complete all as specified and directed. Make : Cromption Greaves Cat Part No. LSTP-60-CDL or equivalent in Philips/Orient/Havells/ Wipro as approved by GE. Note: Driver should be BIS registered with "R" marking.
Energy efficient LED street light fittings of Capacity 45 Watt, Aerodynamically designed street light with excellent thermal management in built tilt angle arrangement with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections and including taking out old unserviceable complete all as specified and directed. Make : Cromption Greaves Cat Part No. LSTP-45-CDL-M or equivalent in Philips / Orient /Havells / Wipro as approved by GE. Note: Driver should be BIS registered with "R" marking.
LED flood light fittings of capacity 120 watt on high mast pole made up of pressue die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection system efficancy 110 LPW with 5 KV surge protection applicable for large area lighting with efficient high output emitter LED for better distributioin and including taking out old unserviceable complete all as specified and directed. Make : Crompton Greaves Cat Part No. LFLN-120-CDL/60-M or equivallent in Orient/Wipro.
LED flood light fittings of capacity 200 watt on high mast pole made up of pressue die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection system efficancy 110 LPW with 5 KV surge protection applicable for large area lighting with efficient high output emitter LED for better distributioin complete all as specified. Make : Crompton Greaves Cat Part No. LFLN-200-CDL/60-M or equivalent in Philips/Orient/Havells / Wipro.
LED flood light fittings of capacity 350 watt on high mast pole made up of pressue die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection system efficancy 110 LPW with 5 KV surge protection applicable for large area lighting with efficient high output emitter LED for better distributioin and including taking out old unserviceable complete all as specified and directed. Make : Crompton Greaves Cat Part No. LSFO-350-CDL/60-M or equivalent in Philips / Orient /Havells / Wipro.
Galvanized steel tubing medium grade, 40mm bore, 1.50 mtr long braket made to shape as directed with 02 Nos clamps made out of MS flat iron 40x6mm of including suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts and including taking out old unserviceable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT electric power cable (ISI marked) with aluminium stranded conductor 1100 volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Note for serial item No. 12.00 to 15.00 : Sand cushioning, cable protection cover and excavation & earth work shall be measured & paid for separately.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT electric power cable (ISI marked) with aluminium stranded conductor 1100 volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT electric power cable (ISI marked) with aluminium stranded conductor 1100 volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT electric power cable (ISI marked) with aluminium stranded conductor 1100 volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed.
Repair only street light and high mast light and building security light any type and any make from pole, hangers, buildings/High mast poles at any height and any type complete after removing from existing bracket, wire, drive and connectors and re-fixing the same after necessary repair and replacement of unserviceable light component complete all as specified and directed.
MCCB, 4 Pole, 400 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830396 or equivalent L&T/Legrand/Siemens/HPL/C&S.
MCCB, 4 Pole, 315 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830395 or equivalent L&T/Legrand/Siemens/HPL/C&S.
MCCB, 4 Pole, 250 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830297 or equivalent L&T/Legrand/Siemens/HPL/C&S.
MCCB, 4 Pole, 200 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830296 or equivalent L&T/Legrand/Siemens/HPL/C&S.
MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830273 or equivalent L&T/Legrand/Siemens/HPL/C&S.
MCCB, 4 Pole, 125 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830243 or equivalent L&T/Legrand/Siemens/HPL/C&S.
MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830242 or equivalent L&T/Legrand/Siemens/HPL/C&S.
MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic adjustable thermal fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB from panel board, complete all as specified and directed. Make : Indo Asian Cat Part No. 830240 or equivalent L&T/Legrand/Siemens/HPL/C&S.
Preparation of surfaces of RCC poles and paint of poles with one coats of aluminium paint over a coat of primer with Navy blue and white strips 30cm wide each upto 1.50mtr height from top of PCC foundation block and numbering of poles complete all as specified and directed
Preparation of surfaces of Steel Poles upto 11 mtr long extension portion and paint of poles with one coats of Aluminium paint over a coat of primer with Navy blue and white over full length and marking of poles number and five strips each 30 cm wide in blue and white colour complete all as specified and directed
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc for laying of cables, pipes, erection of poles, structs/stays etc or not exceeding 10 sqm and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc for laying of cables, pipes, erection of poles, structs/stays etc or not exceeding 10 sqm and getting out in hard dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and exceeding 1.5 metre but not exceeding 1.5 metre in depth for foundation etc for laying of cables, pipes, erection of poles, structs/stays etc or not exceeding 10 sqm and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including in spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified
Dry Sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
Plain cement concrete (1:3:6) Type C-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
Repair of complete LT panel by welding of hinges, door, including door, hings with locking arrangement and layout the LT cable in proper manner by excavation & refilling connecting and taking down existing unserviceable cable including painting of panel complete all as specified and directed.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc complete all as specified. Note : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Earth continuity conductor or main earthing lead 25 x 6mm strip galvanised iron fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required and including disconnecting & taking down old unserviceable complete all as specified and directed. Note : Nut, bolt and other items included in quoted rate by the tenderer.)
6 Sqmm single core PVC insulated, aluminium conductor multi stranded/solid on poles or passing through steel conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc including dismantling/taking out old defective cable form street light poles (Junction box to fitting) complete all as specified and directed. Make : Polycab/Finolex/Havells
Twin core cable 4 sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension and including disconnecting & taking down old unserviceable cable complete all as specified and directed
MCB isolator, 63 Amp, Three Pole, 415 volts, 50 Hz, 1100 volts with necessary modifications in panel Board for connection of MCBs and including disconnecting & taking down old unserviceable complete all as specified and directed
MCB isolator, 63 Amp, Three Pole with neutral, 415 volts, 50 Hz, 1100 volts with necessary modifications in panel Board for connection of MCBs and including disconnecting & taking down old unserviceable complete all as specified and directed
Analog Time switches, 3P Module, 24 hours program, Programmable every 15 min., backup of 100 hours., current capacity 16A, with 1 changeover (1 CO) and including disconnecting & taking down old unserviceable complete all as specified and directed. Make : Indoasian Cat Part No. TA926453 or equivalent L&T/Havells/C&S
Aluminium conductor, steel reinforced (ACSR) of any size, any type, as per existing one and stringing properly on the insulators and binding with aluminium wire 14 SWG, connectors, Jumpers and including disconnecting & taking down old unserviceable complete all as specified and directed. (Note : Measurements and payments shall be made by measuring horizontal distance between centres of two adjacent pole and adding 3% for sag, jointing, jumpers etc).
Pin type insulator, vertical type, porcelain vitreous, white, brown or green for working pressure 11000 volts, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut and including disconnecting & taking down old unserviceable complete all as specified and directed. Make : Jaipuria/Rashtriya
SANJOLI CONSTRUCTION COMPANY
star electricals
M/s Shree Construction Company
Manisha Enterprises
M/s Ramesh & Company
Vinay Traders
AUTOMATION AND SWITCHGEAR CONTROL
Anil Builders
BHARAT NIRMAN INFRASTRUCTURE COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .