Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.3 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹43.9 L+₹3.6 L (9.04%)Rejected-Finance | 2 | Rejected-Finance Other than L-1 | |
| 3 | 3₹48.7 L+₹8.5 L (21.0%)Rejected-Finance | 3 | Rejected-Finance Other than L-1 |
Tender Value
₹38.4 L
EMD Value
₹77,000
Closing Date
16 May 2022, 6:00 pmClosed
Col S S Babu
Headquarters 138 Works Engineers PIN - 914138 C/o 56 APO
SPL REPAIR OF EXISTING WATER SUPPLY SCHEME INCL PIPE AND STATIC WATER TANK UNDER GE 865 EWS AT LEH
2022_MES_515779_2
138 WE/L-12/2022-23
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹77,000
Yes
4 Jun 2022
2 May 2022
23 May 2022
2 May 2022
16 May 2022
9 May 2022
Amount
Excavation in trenches not exceeding 1.5 mtr depth in hard/ dense soil and getting out leveling the bottom surface to required grediant complete all as specified for laying of water supply mains all as specified and directed by Engr-in-charge.
Returning filling in, including leveling watering and well ramming in layers not exc 25cm thick, complete all as specified and directed by Engr-in-charge.
Removal of surplus excavated soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above complete all as specified and directed by Engr-in-charge.
S&F GI tubing 100mm bore medium grade with all fittings and laid in floors or trenches all as specified and directed by Engr-in-charge.
S&F GI tubing 80mm bore medium grade with all fittings and laid in floors or trenches all as specified and directed by Engr-in-charge.
Supply and fix cast iron sluice valve for water supply purpose with CI drilled flanged ends (internal cast 150mm bore class PN 1.6 conforming to IS 780 marked) with stainless steel spindle and iron wheel incl jointed material compete such as rubber packing rings of adequate size and requisite number of nuts, bolts and washers complete all as specified and directed by Engr-in-charge.
All as per item No 6 above but of size 100mm dia complete all as specified and directed by Engr-in-charge.
All as per item No 6 above but of size 80mm dia complete all as specified and directed by Engr-in-charge.
S&F in replacement of cast iron air release valve flanged type heavy duty grade single outlet air release valve 25mm bore and fixing upto 100mm dia CI/DI/GI pipe incl suitable adopter, rubber hinged sheet, nut, bolt etc complete all as specified and directed by Engr-in-charge.
Material and labour for construction of stone masonary valve pit of size 120 x 120 x 90 cm (internal dimension) built in cement mortal 1:4 incl plastering 20mm thick internally and externally in CM1:4 PCC 1:4:8 type D-2 15cm thick in foundation exterding 10cm beyond external faces of wall around PCC flooring 1:2:4 type B1 40mm thick cover made out of 3.15mm thick MS round bar and locking arrangement with lock and keys. MS sheet cover should be painted with two coats of enamel paint over a coat of red oxide primer all as specified and directed by Engr-in-charge.
M&L for submersible pumping set, with discharge capacity 10000 GPH, 76 mtr head ranging 61-124 mtr head with motor capacity 40 HP, 2900 RPM suitable for borewell dia 200mm, pure cold potable water tube well operation complete including supply, lowering, testing and commissioning complete all as specified and directed by Engr-in-charge.
M&L for design, fabrication, installation, testing and commissioning of 70 Amp auto starter cum fault analyser, protection and control panel complrising of the following :- (i) Fabrication of PHU/auto starter with power contractor MNX-70 - 02 Nos, MNX-50 - 01 No of L&T make alongwith MCCB of 100 Amp rating of L&T Make. (ii) The system should be provided with a solid state fault analyser cum controller (CB-4SA) (iii) The complete system shall be enclosed in a floor/ wall mounted MS sheet enclosure/box of suitable gauge and dimension with proper entry and exit holes for incoming and outgoing cables. The enclosure should be finished with powder coated painting from inside as well form outer surface of approved colour. (iv) Providing/ laying of copper cables from stabilizer/ main switch to automation/ protection system (3 leads) and from system to motor (6 leads) with proper thimbing and socketing each end of the conductor with proper rating copper thimbless as per site requirement. The system shall provide protection against :- (a) Low voltage below 360V (b) High voltage above 450V (c) Single phasing (d) Reverse phasing (e) Un balanced phasing (f) Dry running (g) Overloading
Supply and fix PVC insulated, armoured submersible cable 10 Sqmm 3 Core having stranded copper conductor, complete all as specified and directed by Engr-in-charge
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground. (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4mm dia by GI watering pipe with funnel and wire funnel and wire mesh and 15mm dia protection pipe earth work etc complete all as shown in electrical plate No 5 of MES plate No 6 and all as specified and directed by Engr-in-charge.
M/S MOHD KARIM
SONAM TUNDUP
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .