Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹19,429
Closing Date
10 Jun 2021, 1:30 pmClosed
A.P Tyagi je
BSNL, Electrical Division, GPO Compound, Meerut Cantt.
Attending the faults of Electrical Installations and accessories in Telephone Exchanges in OA Meerut.
2021_BSNL_631485_1
02/NIT/EE(E)/BSNL/ED/MT/21-22
Open Tender
Miscellaneous Works
Item Rate
365 days
Meerut
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Accounts Officer Cash, B.S.N.L., O/o GMTD, Meerut.
₹19,429
19 Jun 2021
28 May 2021
11 Jun 2021
28 May 2021
10 Jun 2021
28 May 2021
(SH-I Labour Charges for attending the fault) (1) Providing of one Semi-Skilled (Electrician) and one un-skilled labour for attending faults on call basis without material for rectification of fault of non functioning of the E.I, Compound Light, power supply from meter to panel, Distribution board, changeover switch i/c removing the fault, testing etc. complete as reqd. (a) The semi-skilled person (Electrician) should be able to work on electrical components, such as Electrical wiring, testing, circuit breakers, Distribution board and Electrical panel work. (b) At least 2 years' experience as an Electrical Technician. (c ) General duty hours from 10:00 am to 05:30 pm but in emergency the maintenance staff shall be available at any time. (d) The sitting arrangement and telephone for the staff engaged by the agency should be arranged by the firm at his own cost. The Enquiry office space & electricity shall be made available by the Department free of cost. (e) Replacement of defective/damaged material shall be provided separately. Recovered item from replacement shall be property of contractor.
(2) Transportation charges for attending faults from enquiry office to site and site to Enquiry office etc. complete as reqd. (The journey shall be performed by two wheeler /Motor cycle /scooter, the vehicle shall be arranged by agency) (a) Within 25 Kmtrs
2(b)Within 50 Kmtrs
(SH-II Replacement of Electrical Installation and accessories) Replacement of following electrical, mechanical component and accessories etc. complete as required. (1) Tube light 36 W (M/s Philips/Bajaj/Crompton Make)
2) Choke copper for 36 W Tube light (Electronic)
3) Starter for 20/40/80 W for tube light
4) LED Tube light 20 W for 4 fit fitting
5) 5/6 Amps switch piano type (Anchor Make)
6) 3 Pin 5/6 A socket outlet piano type (Anchor Make)
7) 15/16 Amps switch piano type (Anchor Make)
8) 6 Pin 15/16 A socket outlet piano type (Anchor Make)
9) Fan Regulator ISI marked
10) 5/6 Amps switch modular type (Anchor Roma Make)
11) 3 Pin 5/6 A socket outlet modular type (Anchor Roma Make)
12) 15/16 Amps switch modular type (Anchor Roma Make)
13) 6 Pin 15/16 A socket outlet modular type (Anchor Roma Make)
14) Stepped typoe Electronic fan regulator (modular) (Anchor Roma Make)
15) Call bell/buzzer suitable for D.C./A.C. single phase, 230 volts
16) 18 Watt LED Bulb (M/s Crompton/ Philips make)
17) 20 Watt LED Bulb (M/s Crompton/ Philips make)
18) 23 Watt LED Bulb (M/s Crompton/ Philips make)
19) 40 Watt LED Bulb (M/s Crompton/ Philips make)
20) Energy eificient 30 Watt LED Street Lights fitting (M/s Crompton Model Astra NEO LSTS-30-CDL-M / SS make)
21) Energy eificient 40 Watt LED Street Lights fitting (M/s Crompton Model Freedom NEO LSTS-40-CDL-M / SS make)
22) Brass Batten holder
23) Dome/ Cover for Gate Light Fitting (M/s Philips, S.S. make)
24) Water proof FRP/SMC Single pic.molded box (M/s Sintex make)
25) 5-32 Amp SP MCB 'C' Series (M/s Legrand / S.S make)
26) 5-32 Amp DP MCB 'C' Series (M/s Legrand / S.S make)
27) 5-32 Amp TP MCB 'C' Series (M/s Legrand / S.S make)
28) 63 Amp Double Pole Isolater (M/s Legrand / S.S make)
29) 63 Amp Four Pole Isolater (M/s Legrand / S.S make)
30) 2 Way DP Enclosure (M/s Legrand / S.S make)
31) 63 Amp 4 pole 'ON LOAD' changeover switch with sheet steel enciosure (M/s HPL / S.S make)
32) 63 Amp 4 pole 'ON LOAD' changeover switch without sheet steel enciosure (M/s HPL make).
33) 100 Amp 4 pole 'ON LOAD' changeover switch with sheet steel enciosure (M/s HPL make)
34) 100 Amp 4 pole 'ON LOAD' changeover switch without sheet steel enciosure (M/s HPL make)
35) 63 Amp TPN, SDFU with HRC fuse (M/s L&T make)
36) 96 mm x 96 mm Digital Voltmeter, (0-500) V (M/s A.E./ Rishabh/ HPL make)
37) 96 mm x 96 mm Digital Ammeter, (0-200) Amp (M/s A.E./ Rishabh/ HPL make)
38) LED incication lamp Red/ Yellow
39) LED incication lamp Blue
40) 100 Amp 4 Pole MCCB, 25 KA breaking capacity, release range (80-100A) [M/s L&T DN0-100C make]
41) 125 Amp 4 Pole MCCB, 36 KA breaking capacity, release range (100-125A) [M/s L&T DN0-125D make]
42) 63 Amp Porocilin Kitkat fuse carrier & Base
43) 100 Amp Porocilin Kitkat fuse carrier & Base
44) HRC Fuse 5-32 Amp
45) Supplying and drawing/laying of following size FRLS PVC insulated copper conductor, single core multistrand wire/ cable in the existing conduit/surface/casing caping etc complete as reqd. (a) 3 x 1.5 Sqmm
45(b) 3 x 2.5 Sqmm
45(c ) 3 x 4.0 Sqmm
46) Supplying & Laying of following size PVC insulated PVC sheathed Al. conductor armored cable of 1.1 KV grade on surface/ wall etc. complete as required. (a) 2 x 6 Sq.mm
46(b) 4 x 16 Sq.mm
46(c ) 3 1/2 x 35 Sq.mm
47) Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade size not exceeding 35 Sqmm in the following manners :- (a) Direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
47(b) On Surface as required
47(c ) In the Existing RCC/HUME/METAL pipe as required
47(d) In the Existing masonry open duct as required.
48) Supplying & making end termination with brass compression gland and Alum. Lugs for following size PVC insulated and PVC sheathed/XLPE Alum. conductor cable of 1.1 KV grade as required. (a) 2 x 6 Sq.mm (19mm)
48(b) 4 x 16 Sq.mm (28 mm)
48(c ) 3 1/2 x 35 Sq.mm (32 mm)
(SH-III Rewinding work) 1.) Rewinding and assembling of following submersible pump motor with oil seal and including replacement of all necessary spares parts in motor and pump required as impleller, bushing etc for smooth functioning of submersible pump complete in all respect i/c dismantling and lowering of pump etc complete as reqd. (a) 1.0 HP
2.) Rewinding and overhauling of following exhaust fan replacement of bushes bearing shaft including capacitor etc. complete as required. (a) 9" Exhaust fan
2(b) 12" Exhaust fan
2(c ) 18" Exhaust fan
3.) Rewinding and overhauling of following ceiling fan including bushes, bearing, bearing shaft and capecitor etc. complete as required. (a) 48" Ceiling fan
3(b) 56" Ceiling fan
Harsh Electrical
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .