Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.0 LAccepted-Finance | ₹12.0 L | L-1 | Accepted-Finance Being L-1 |
| 2 | L-2₹12.9 LRejected-Finance 01 NEW MATTAN ADDA ANANTNAG ANANTHNAG JAMMU KASHMIR 192101 UDYAM JK 01 0000225 | ANANTNAG | JAMMU AND KASHMIR | 192101 | ₹12.9 L | L-2 | Rejected-Finance Not Being L-1 |
| 3 | L-3₹13.1 LRejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | ₹13.1 L | L-3 | Rejected-Finance Not Being L-1 |
| 4 | L-4₹13.3 LRejected-Finance | ₹13.3 L | L-4 | Rejected-Finance Not Being L-1 |
| 5 | L-5₹13.4 LRejected-Finance KHUNMOH SRINAGAR PIN 191104 J K | SRINAGAR | SRINAGAR | J K | 191104 | ₹13.4 L | L-5 | Rejected-Finance Not Being L-1 |
| Sl No | Description | Qty | Unit | M/S SHEIKH FEROOZ AHMAD L3 | M/S HAFIZ AND SONS L5 | M/S NEW IQBAL ENTERPRISES L4 | M/S MUHIBULFUKARA ENTERPRISES L1 | Asian Marketing Co L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type soil complete all as specified and as directed by Engineer-in- charge. | 44.6 | Cum | 250 ₹11,150 | 260 ₹11,596 | 300 ₹13,380 | 175 ₹7,805 | 190 ₹8,474 |
| 2.00 | Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. | 4 | Cum | 3,500 ₹14,000 | 3,700 ₹14,800 | 2,800 ₹11,200 | 4,000 ₹16,000 | 2,500 ₹10,000 |
| 3.00 | Material & Labour for Walling of random rubble stone , uncoursed , well bonded,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. | 6.6 | Cum | 5,000 ₹33,000 | 5,100 ₹33,660 | 4,500 ₹29,700 | 1,800 ₹11,880 | 3,200 ₹21,120 |
| 4.00 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. | 2.5 | Cum | 8,500 ₹21,250 | 8,400 ₹21,000 | 7,900 ₹19,750 | 5,900 ₹14,750 | 6,500 ₹16,250 |
| 5.00 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. | 2.3 | Cum | 8,500 ₹19,550 | 8,200 ₹18,860 | 8,200 ₹18,860 | 6,500 ₹14,950 | 7,100 ₹16,330 |
| 6.00 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Chajjas complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items. | 0.4 | Cum | 8,500 ₹3,400 | 8,000 ₹3,200 | 9,000 ₹3,600 | 7,200 ₹2,880 | 8,000 ₹3,200 |
| 7.00 | Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Slabs supported on walls,beams and columns infloors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like Slabs supported on walls,beams andcolumns in floors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like as specified and as directed by Engineer-in-Charge | 0.75 | Cum | 8,500 ₹6,375 | 7,500 ₹5,625 | 9,000 ₹6,750 | 7,000 ₹5,250 | 8,000 ₹6,000 |
| 8.00 | Material & Labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge. | 17 | Sqm | 250 ₹4,250 | 300 ₹5,100 | 400 ₹6,800 | 150 ₹2,550 | 350 ₹5,950 |
| 9.00 | Material & Labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;
not exceeding 200mm thick (Horizontal or sloping) on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge. | 4 | Sqm | 250 ₹1,000 | 320 ₹1,280 | 400 ₹1,600 | 150 ₹600 | 300 ₹1,200 |
| 10.00 | Material & Labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. on flat rough finished surface of concrete complete all as specified and as directed by Engineer-in-Charge. | 23 | Sqm | 250 ₹5,750 | 280 ₹6,440 | 400 ₹9,200 | 250 ₹5,750 | 400 ₹9,200 |
Updated dates
Tender Value
₹13.6 L
EMD Value
₹27,200
Closing Date
9 Apr 2026, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
PROVN OF 01 X TOILET BLOCK AGAINST JOB NO. 24/REV/5S/2024-25 AT AGE B/R (P) KHANABAL UNDER GE 861 EWS
2026_MES_756061_1
GE 861 EWS-75(T)/2025-26
Open Tender
Civil Works
150 days
GE 861 EWS
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 861 EWS
₹27,200
GE 861 EWS
6 Jun 2026
12 Mar 2026
13 Apr 2026
12 Mar 2026
9 Apr 2026
27 Mar 2026
18 Mar 2026
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type soil complete all as specified and as directed by Engineer-in- charge.
Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Walling of random rubble stone , uncoursed , well bonded,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items.
Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items.
Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Chajjas complete all as specified and directed by Engineer-in-Charge.NOTE :- Form work and Steel reinforcement shall be measured and paid seperately under appropriate items of Schedule 'A' BoQ.seperate items.
Material & Labour for Reinforced cement concrete (Design Mix) M-25 as in Slabs supported on walls,beams and columns infloors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like Slabs supported on walls,beams andcolumns in floors,roofs, landings, balconies,canopies, deck slabs and inshelves and the like as specified and as directed by Engineer-in-Charge
Material & Labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) on rough finished flat surface of concrete complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. on flat rough finished surface of concrete complete all as specified and as directed by Engineer-in-Charge.
Material & Labour Formwork to chullah hoods, chajjas,troughs and similar items including edges on flat rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Material and labour Brickwork with sub class 'B' old size burnt clay bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Material & Labour for 40mm thick PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engineer-in-Charge
Material & Labour for Hardcore of broken stone or boulders ,gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge..
Material & Labour for 100 mm thick PCC 1:4:8 ,Type-D2 ,using 40mm graded stone aggregates as in sub base of flooring complete all as specified and directed by Engineer-in-Charge.
Material and labour for 50 mm thick PCC (1:3:6) Type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection / path etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge
Material and labour Joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
Material and labour Coloured Glazed ceramic tiles in vertical surface 350mm x 250mm x 7 mm / 450mm x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering of cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
Material and labour for Rendering 10mm thick in Cement Mortar 1:6 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for Rendering 15mm thick in Cement Mortar 1:4 , on fair faces of brick work or concrete surfaces of walls , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for Rendering 5mm thick in Cement Mortar 1:3 , on concrete surfaces of ceiling , finish even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour including preparation of newely plastered surfaces of wall and applying with three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new surface of walls, with and including two coats of cement base paint ,over with and including one coat or alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
Material and labour including preparation of newely plastered surfaces of ceiling and applying with three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) Fe 410 -W (Gde- E- 250) quality-A including distance pieces, cleats etc. complete all as speicied and as directed by Engineer in charge.
Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Mild steel Pressed steel frames with thickness of steel sheet 1.25mm for doors with one or more rebates including hinges, lock strike plate, fixing lugs, etc., size of frame 105mm x 60mm including one shop coat of priming complete all as specified and as directed by Engineer-in-charge.
Material & Labour for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in filling of hollow portion of pressed steel door frame complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing Factory made 35mm thick framed, panelled shutter (two panel) with lock rail made of 2nd class Hard wood and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge. Note: Butt Hinges, Tower bolts, Handles , sliding door bolts and painting shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.
Supply & Fixing Solid PVC door frame of size 50mm x 47mm made out of 5 mm single side prelam PVC sheet reinforced with MS square tube manufactured as per SSR Part-I specifications and drawings complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing Butt hinges size of 100mm , medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 100mm long steel butt hinges and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 150 mm long Extruded aluminium alloy handles, fabricated type,anodised as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of newely steel surfaces of any description, over 10 cm in width or girth or otherwise described , with and including applying two coat of syntheic enamal paint over with and including one coat of red oxide zinc chrome primer complete all as spefied and as directed by Engineer-in-Charge.
Material and Labour for preparing wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing 15mm bore GI tubing medium grade with all new fittings to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 20mm bore GI tubing medium grade with all new fittings to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 15mm bore bib tap cast copper alloy, chromium plated, fancy type (ISI marked) with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
Supply and fixing 15 mm bore stop valve / angle valve, Chromium Plated, cast copper alloy (ISI marked) screwed down , high pressure with crutch or butterfly handle fancy type complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 15mm bore stop valve fancy type Chromium Plated , cast copper alloy, with capstan heads, chromium plated with long shank and cup ( concealed ), (ISI marked) screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 20mm bore Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for iron pipes complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge.
Supply & Fixing 15mm bore PVC connection with PTMT nuts of 450 long complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) 75 mm bore pipes single socketed, (ISI Marked ) fixing with using adhesive, in any length laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge. Note: Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule of BoQ.
Supply and fixing PVC (SWR) 110 mm bore pipes single socketed, (ISI Marked ) fixing with using adhesive, in any length laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge. Note: Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule of BoQ.
Supply and fixing PVC (SWR) Bends 75 mm bore in any radius (ISI Marked ) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) Bends 110 mm bore in any radius (ISI Marked ) complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 110mm bore PVC (SWR) 'P' Trap (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 110mm bore PVC (SWR) WC Connector bent type (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 100 mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Vitreous China squatting pan of pattern “long pan”, size 580 mm white with ‘P’ or ‘S” trap, front or back inlet and foot rests,any pattern complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing water closet vitreous china squatting pan, Orissa pattern size 580mm x 440mm white with integral foot rests with and including provision of lime concrete bedding with and including `P' trap and connection to drain and to flushing pipe anti symphonage pipe complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Vitreous China Urinal, Half stall type, white complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle , with and including brackets, with and including 32 mm dia flush pipe of polyethylene of low or high density of PVC complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing Vitreous China wash basin, white, flat back, size 630mm x 450mm with Mild steel brackets, with and including cutting for and pinning in ends of brackets or erecting stand, with and including waste fittings of brass chromium plated ,with and including 32mm dia PVC waste pipe of required length complete all as specified and directed. as directed by Engineer-in-Charge.
Material & Labour 2nd class Soft wood plain fillets square/rectangular or triangular in section of sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm splayed chamfered or rounded on one edge or face complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 2nd class Soft wood Plain fillets area exceeding 6 Sqcm and not exceeding 13 Sqcm. square, rectangular or triangular in section, clean sawn, secured with nails or brads. complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 6mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face fixed with screws to timber frame work complete all as specified and directed by Engineer-in-Charge.
Removing excavated material of any type of soil not exceeding 50m and depositing where directedc at a level n exc 1.5 mtr above the starting point . complete all as specified and directed by Engr- in- charge.
Returning filling in, approved soft/loose soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing looking mirror of plain glass 1200mm x 900mm x 4-6m thick mounted on wall tilling with steel screws studs 04 Nos complete all as per direction of Engineer-in- Charge.
Material & Labour for Brickwork with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 150mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed by Engineer-in Charge.
Material and labour for PCC (1:3: 6) type C-2 using 40 mm graded stone aggregates as in concrete bed for drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested including form work complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm.(iii) Excavation , earth work , returning filling shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.
Material and Labour for for precast rainforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as landing, cover slabs for man holes etc. chullah hoods, chajjas, water troughs,mangers,shelves and similar articles with plain faces and jionted in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge,
Material and Labour for Construction of soakage well of size 2.40 mtr dia x 3.00mtr effective depth includingearth work such as excavation in any type of soil, returning filling and removal of earth work , foundation in PCC 1:3:6 Type-C-1 using 20mm graded stone aggregates, Honey combing Brick massony built with burnt clay old size bricks ,Top ring made with RCC M-25 Design Mix ,intercepting chamber and screen made with burnt clay old size brick with cement mortar 1:4, RCC M-25 Design Mix cover slab , 150mm bore DWCPE (SN 8) drain pipes 150 mm nominal dia as per IS-16098 (Part-II) interconnecting pipes , filled with brick bats compete all as shown in drawing No.CESZ/TD-36/ST/20 SHEET 1/2 AND 2/2 DATED 22-02-2020
Material and Labour Construction of LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 20 users complete all as specified and directed by Engineer-in-Charge.
Material and Labour for PCC 1:3:6, Type C1 using 20mm graded stone aggregate as in coping with and including form work and finishing the exposed faces of concrete even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed by Engineer-in- charge. Note:- Inner girth shall only be measured for payment. Nothing extra shall be paid on this account.
Material and labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with 1.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked , with and including PVC casing and capping of medium grade of suitable size and run on wall / surface with all fittings (ISI Marked) with and including one single core 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) (as in green colour) as continues earth wire connected to earth dolly etc. controlled by one switch for one light point/ fan point with and including CI/MS/ wooden sunk box of required size with and including 3mm thick plastic laminated sheet cover & as directed by Engineer- in- Charge Notes for serial item nos.81.00 to 83.00 : (i) switches one way 5 /6 Amp , switches one way 15 /16 Amp, socket out lets 5 /6 Amp & socket out lets 15 1/6 Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ.
All as per srl item No.82.00 here- in- before but for One 3 pin socket outlet, 5 Amps, on the same board complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 82.00 of BoQ here-in-before but 2.5 Sqmm two single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable 1100 volt grade ISI Marked with and including one single core 2.5 Sqmm FRLSH PVC insulated multi strand copper conductor cable 1100 volt grade (ISI marked ) as continues earth wire connected to earth dolly etc for 3 pin socket outlet 15 Amps with complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Switch piano flush type 5 Amp single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal 240 volt (ISI Marked ) complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Switch socket combination 2 in 1, 3 pin, 15 Amp flush type universal 240 volt (ISI Marked )complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65mm x 50mm three terminals ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Lamp holder Angular / Straight ISI marked , insulated body , with back plate for batten fittings complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing LED Lamp 10Watt ,230 Volt, AC Supply,, Energy efficien, long life complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing Decorative ultra slim linear LED 20 Watt 4 Feet Long lighting fixture with extruded aluminium heat sink,environment friendly, Energy efficient , ready to use pack with and including LED Tube complete , with inbuilt electronic driver, PCB, Connector block complete all as per manufactureres instructions with and including connecting up with theree copper flexible cable from ceiling rose to fitting including connectiong up and fixed on with and including two nos.square box of required size complete all as specified and directed by Engineer-in-charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
Supply & Fixing LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:- (a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door,08 modules, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items. (ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account.
Supply and fixing MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SPN 32 Amp , rupturing capacity not less than 10 KA 'C' curve 230 V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply & Fixing Exhaust fan 300 mm sweep , made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, ISI marked, including necessary work in wall/sheet, including connection cable, nut bolt and other fixing material complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing water heater (Geyser) Auto restrat and safety measures type electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections and carrying out grounting & complete installations with mounting bolts,nuts including testing after installation complete all as specified & directed by Engr-in- Charge.
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 2 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply & Fixing 20mm bore GI tubing medium grade with all new fittings laid in trenches complete all as specified and directed by Engineer-in-Charge. Note: Excavation and earth work shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.
Supply & Fixing 25mm bore GI tubing medium grade with all new fittings laid in trenches complete all as specified and directed by Engineer-in-Charge. Note: Excavation and earth work shall be measured and paid seperately under appropriate items of schedule 'A' BoQ.
Supply and fixing 25mm bore Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for iron pipes complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Cutting of existing CI / GI pipe line of 20mm to 50mm bore and inserting with and including NEW TEE of appropriate size and taping new connection with all accessories complete all as specified and as directed by Engineer-in-charge. Note: The rate of supply and fixing of NEW TEE of appropriate size is included in this item.Hence bidder shall be quoted his rates accordingly and nothing shall be paid extra on this account.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender75T.pdf
Tender Documents • 4.32 MB
BOQ_846882.xls
BOQ • 5.10 MB
Download all tender documents and submit your bid