Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 12 GURU NANK AUTO MARKET KASHMERE GATE DELHI 110006 | NORTH | DELHI | 110006 | Admitted-Finance |
| 2 | Admitted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | Admitted-Finance |
| 3 | Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹16,400
Closing Date
3 Aug 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(SDW)-XI
Kilokari SPS Jal Vihar New Delhi
N.I.T. NO.05 EE(SDW)-XI 2022-23 ITEM NO. 3
2022_DJB_226405_3
N.I.T. NO.05 EE(SDW)-XI 2022-23
Open Tender
Miscellaneous Works
Works
30 days
Work
Please refer tender documents
3 documents required · 3 mandatory
₹500
ONLINE
₹16,400
Yes
16 Aug 2022
20 Jul 2022
3 Aug 2022
20 Jul 2022
3 Aug 2022
20 Jul 2022
120 days
Shunt capacitors power 3 phase,415V AC 50Hz MPP type heavy duty in suitable banking as per requirement to maintain power factor (150Kvar x2 Nos. APFC Panels) Make: Epcos/,L&T /DJB approved Make
Automatic power factor correction relay 415V digital type 8stag Make: L&T/Neptune/Epcos/Entes
MCCB of 320Amp. 415V AC TP 3 phase 50HZ for incomer braking capacity with spreader terminals and handle 36KA Make: L&T/Siemens
MCCB of 63Amp. 415V AC TP 3 phase 50HZ with spreader Make L&T/Siemens
MCB of 12-32Amp. 415V AC 3 phase 50HZ Make L&T/Siemens
Digital Amp. Meter make: AE/L&T
Digital Volt meter Make; AE/L&T
Power contactor 220V AC 70Amp Make: L&T/Siemens
Power contactor 220V AC 40Amp Make: L&T/Siemens
Power contactor 220V AC 25Amp.Make: L&T/Siemens
Power contactor 220V AC 12Amp.Make: L&T/Siemens
Indicating lights LED type 220V ON & RYB make: siemens/vaishnav
Current transformer300/5 for current measurement make: AE/Saviour
Aluminum Main bus-bars, links, bends sets duly sleeved with heat shrinkable sleeve suitable for 150Amp. Current carrying capacity in suitable cross section of electrical grade 55%conductivity
Sensing current transformer of suitable ratio of in-comer for current sensing Make; AE/Advance
S/o fabricated A.P.F.C .panel board enclosure in (1400mm X1200mm X350 mm) 2mm CRCA sheet, cubical type, floor mounting dust 10800.00vermin proof with gas cut bidding ,neutral13260.00 link terminal block and having chamber9520.00 as suitable to fix the above mention capacitors banks & switchgears to be fitted in with provision for cable entry & Base frame made out of MS channel as suitable to fix the A.P.F.C. panel .
Static capacitor panel across transformer Shunt capacitors power 3 phase,415V AC 50Hz MPP type heavy duty 15Kvar X2 Make: Epcos/L&T
MCCB 40-63Amp.3Phase,415V TP with spreader & handle 36Ka Make L&T/Schneider
MCB 6- 32Amp.3Phase,415V Make L&T/Schneider/Siemens
Fabrication & supply of MS enclosure SIZE (600MMx600MMx200MM) in 2mm CRCA sheet with base frame duly painted for fixing the capacitor unit & above mention switchgears With lockable door front opening and suitable to install at site.
Installation, commissioning, testing of the capacitor unit across the transformer with cable connection both incoming & out going with thimbling, required hardware & required civil work at site.
Dismantling of old panel & Installation of the new APFC panels at site with required hard ware This includes Testing& commissioning of the all installed components in APFC panel and setting of APFC relay to get proper power factor. Testing & commissioning of the APFC panel with relevant IS as follow: - Check equipments specification - Continuity and ear thing -MCCB mechanism and alignment -Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests -Checking for all tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF -Alignments of doors etc. -interlocking tests
Premier Engineering Company
M G Traders and Engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .