| 1 | L1₹13.4 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.7 L+₹7.3 L (54.9%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.5 L+₹8.1 L (60.5%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Mar 2020, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
COMPREHENSIVE MAINTENANCE OF AMF PANELS,CHANGEOVER SWITCHES AND EARTHINGS AT DG SET INSTALLATION AT AF STN YELAHANKA
2020_MES_331332_1
8768/E8
Open Tender
Civil Works
Item Rate
330 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹40,000
Yes
22 Jun 2020
4 Mar 2020
30 Mar 2020
4 Mar 2020
28 Mar 2020
16 Mar 2020
Amount
250/200 KVA AMF panel (200KVA=04 Nos and 250 KVA =01 No)(5Nos x 11 months)
200 KVA with out AMF panel
160 KVA AMF panel
125 KVA AMF panel
125 KVA without AMF panel
100 KVA AMF panel (100 KVA = 03 Nos)(3Nosx11Months)
100 KVA without AMF panel (100 KVA = Mobile DG 02 Nos)(2Nosx11Months)
62.5/50 KVA AMF panel( 62.5 KVA=02 Nos, 50 KVA =01 N)(3Nosx11Months)
22.5/15KVA AMF panel ( Middle marker/CADF)((2Nosx11Months)
Supply and Fix in repair of Current Transformer 400/5 make: AE
Supply and Fix in repair of Current Transformer 300/5 make: AE
Supply and Fix in repair of Current Transformer 200/5make: AE
Supply and Fix in repair of Current Transformer 30/5 make: AE
Supply and Fix in repair of Power factor meter , 3 phase Digital type.Make : CONZERV Ref. 30002572
M&L for providing cable tag made out of 2 mm thick aluminium plate of size note exeeding 75mm x 25mm clearly engraved "the size of the cable , feeding to & connected to pole No." and tightly clamped to the cable all as directed at site. Note :- The cable size , feeding area & the pole No. connected shall be identified by the contractor correctly.
Supply & Fixing in repair of OFF load change over 200 A 4 pole 415 V Make: Havells or equivalent.
Supply & Fixing in repair of on loads Change over switch 630 A , 4 pole front handle ss enclosure- double end. Make: Havells or equivalent.
Supply & fixing in repair of MCCB 4 pole with neutral link 100 A rating, 25 KA with 80-100 thermal settings as outgoing feeders confirming to L&T make or equivalent
Earthing complete with copper plate electrode of size 600x600x3mm thick burried directly in ground (earth pit not less than 2,25 mtrs deep below ground level) with top edge of the plate not less than 1,5 m below ground level , connected copper strip of size 25mm x 3 mm with DG sets , LT panel / AMF Panel etc.
Supply and laying copper strip [size of 25 x 3 mm ] connect to various eath points etc as reqd.
Supply and laying protection G I pipe size of 40mm,light grade
Taking down the unserviceable changeover switch after disconnecting from LT panel board ,supply and fix new on load type Changeover SS enclosure 415 volts 200 amps 4 pole 50Hz and including necessary fabrication , addition alterations all as directed.
Taking down the unserviceable changeover switch after disconnecting from LT panel board ,supply and fix new on load type Changeover SS enclosure 415 volts 400 amps 4 pole 50Hz and including necessary fabrication , addition alterations all as directed.
Taking down the unserviceable MCCB after disconnecting from panel board ,supply and fix new MCCB 415 volts 250 amps 4 pole 50Hz and including necessary fabrication , addition alterations all as directed.
Repair, testing and servicing for 125KVA SCVS Note: All spares will be issued/measured and paid separately under the item 18.01 to17.05
Replacement in M25R PCB
Replacement in of 60V Variac
Replacement of carbon brush
Replacement of micro switch limit
Replacement of PT
Repair, testing and servicing complete for 150KVA SCVS.Note : All spares will be measured and paid separately under item no.19.01 to 18.03
Replacement in M25R PCB
Replacement of PT
Replacement Neon lamp
Repair, testing and servicing complete for 50KVA SCVS Note: All spares will be issued/measured and paid separately under item no.20.01&20.02
Replacaement of PT
Replacaement of 40A carbon brush
Repair, testing and servicing complete for 20KVA SCVS Note: All spares will be issued/measured and paid separately under item no. 20.01 to 20.05
Replacement in M25R PCB
Replacement of Auto/ manual Swich
Replacement of pushbutton switch
Replacement of PT
Replacement Neon lamp
Repair, testing and servicing complete for 10KVA SCVS Note: All spares will be issued/measured and paid separately under item no.21.01 to 21.02
Replacement in M25R PCB
Replacement of PT
Replacement of DOL starter for motor cap upto 7.5 HP
Filtering the transformer oil with streamline filteration plant having dielectric strength below 60KV
Supply and toping up of new transformer oil
Supply& fixing in repair of Contactor 4P, cosmic star, Havells (CH1, 1150F)Cat No. 1HPAC115100
Supply & fixing in repair of Main Contactor 300A, 4P (LOVATO/L&T) Cat No. CS97023
Supply & fixing in repair of DG Contactor 200A, 3P (L & T), Model: ML10 Cat No. SS90935
Supply & fixing in repair of DG Neutral contactor, MNX25 (L&T) 3P ,1 NO + 1NC Cat No.- CS94110
Supply & fixing in repair of Aux Contactor 230AC - 2NO + 2NC (L&T) Cat no. CS94020
Supply & fixing in repair of Contactor (L&T) (MCX 11)63A, 4P make: L&T Cat no. CS97013
Supply & fixing in repair of Mains contactor 300A, 3P, 230V - ML-12, with Add on block 2NO-2NC (L&T) Cat no. SS91010
Supply & fixing in repair of Mains Neutral Contactor - 3P, 230V with Add on Block (L&T) MNX 45 Cat no. CS97074
Supply & fixing in repair of DG Contactor 400A, 3P, 230V AC(L&T) MNX 325 (with Add on Block) Cat no. CS94143
Supply & fixing in repair of DG Contactor, 400A, 3P, 240V AC, MNX-265 (L&T) Cat no. CS94142
Supply & fixing in repair of Contactors - MNX-400, 400A-3P, 230V Cat no. CS94144
Supply & fixing in repair of Neutral Contactor-MNX-70, 3P, 230V Cat no. CS97076
Supply & fixing in repair of AUX Contactor (Telemechanic) DC
Supply & fixing in repair of AUX Contactor (Telemechanic), AC
Supply & fixing in repair of Contactor - TC, LCI FDP-265A with Add on block
Supply& fixing in repair of Neutral Contactor (Sprecher Schuh/L&T ) CAB - 72. N=11 with add on block(25A 3P)model 6A343N11
Supply & fixing in repair of Contactor (MCX22) - 4P-2Nos, 63A Cat no. CS97017
Supply & fixing in repair of Aux Contactor (TC) (TCI M6) with Add on block
Supply & fixing in repair of (MNX110) Contactor (L&T) 3P, 110A Cat no. CS94137
Supply & fixing in repair of Neutral Contactor (MNX25) 3P, 25A (L&T) Cat no. CS94110
Supply & fixing in repair of Contactor (L&T) (MCX-11) 50A-4P with Add on block Cat no.- CS97013
Supply & fixing in repair of Contactor (MNX12) (L&T) 30A 3 pole
Supply & fixing in repair of AUX Contactor with Timer (TC/L&T) Cat no. D847F2
Supply & fixing in repair of Contactor (MCX-03) (L&T) 230V AC, 32A Cat no. CS97011
Supply & fixing in repair of HRC Fuse with Carrier 200A (L & T) Cat no. SF94132
Supply & fixing in repair of HRC Fuse links - 6A-20A cat no. SF90146
Supply & fixing in repair of HRC Fuse links 400A (Havells) Cat no.SF94335
Supply & fixing in repair of HRC Fuse links - 250A Cat no. SF94333
Supply & fixing in repair of HRC Fuses links - 80-100A
Supply & fixing in repair of VCT1 D2 (Minilec) 415V AC
Supply & fixing in repair of OFS D1 (Minilec) 240V AC
Supply & fixing in repair of VSP D2 (Minilec) 240V/415V
Supply & fixing in repair of LVM -(Minilec)
Supply & fixing in repair of AID1 Timer 230V AC/DC 0-30V AIDI-X(CSA)
Supply & fixing in repair of Timer GIC (L&T) ETR-600, DC Cat no. VODDTDI
Supply & fixing in repair of Timer GIC (L&T) ETR-600 AC. Cat no. VODDTDI
Supply & fixing in repair of Pla Relay 230V AC/30V DC
Supply & fixing in repair of Battery charger (Naren) 24V, 20A
Supply & fixing in repair of Battery Charger 12V, 10A model-Amps Make-nhp
Supply & fixing in repair of MCCB (DU 100) (L&T) 50A 3P 10Ka Cat no CM977560000
Supply & fixing in repair of MCCB (DU100) 25A, 3P (L&T) Cat no.CM977530000
Supply & fixing in repair of 100A MCCB (DU-100) [L&T] 3P Cat no-CM989220000
Supply & fixing in repair of Indicator (LED) 230VAC/30V DC Cat no. -SIL
Supply & fixing in repair of Digital Voltmeter (Meco)0 to 500V model DM3210
Supply & fixing in repair of Digital Ammeter (Meco)0 to 1000A Model DM3110
Supply & fixing in repair of Frequency Meter make:meco DM1310
Supply & fixing in repair of GCU 101 (Utopia) Control Unit
Supply & fixing in repair of OLR (L&T) cat no. SS9414500
Supply & fixing in repair of Relay Salzer - MSP-2P SA, 240V AC, 5A, 12VDC
Supply & fixing in repair of Relay (ARC 25P12) 12VDC Salzer
Supply & fixing in repair of Relay Card
Supply & fixing in repair of Magnatic Relay - 12V DC
Supply & fixing in repair of Push Button (TEKNIC/VAISHNO) with Elements NO+ NC element
Supply & fixing in repair of S. Switches - Voltmeter Cat no. 61312SBB13TDYR, 10 A
Supply & fixing in repair of S. Switches Ammeter. Cat no. -61325SCBO3TDHR, 16 A
Supply & fixing in repair of ING Key
Supply & fixing in repair of C.T (Nippen) 25/5A
Supply & fixing in repair of C.T. 100/5A
Supply & fixing in repair of euroload changeover switch 63A 4pole Make: Havells Cat no.-1HCVF00063
AIRMEN MESS
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required ( Once in a six month )
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required, Burning of ducting and blower, balancing of impeller, painting, replacements of nuts and bolts, rivets etc.(Once in a Year ) (a) SS Hood cleaning
Grease filters cleaning
servicing and repairs including windings of Exhaust Blower of 5 HP
SNCO’S MESS
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required ( Once in a six month )
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required, Burning of ducting and blower, balancing of impeller, painting, replacements of nuts and bolts, rivets etc.(Once in a Year ) (a)SS Hood cleaning
Grease filters cleaning
Exhaust Blower of 3 HP
GI Ducting ( Approx )
FLIGHT CADET MESS
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required ( Once in a six month )
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required, Burning of ducting and blower, balancing of impeller, painting, replacements of nuts and bolts, rivets etc.(Once in a Year ) (a)SS Hood cleaning
Grease filters cleaning
Exhaust Blower of 3 HP
GI Ducting ( Approx )
OFFICERS MESS
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required ( Once in a six month )
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required, Burning of ducting and blower, balancing of impeller, painting, replacements of nuts and bolts, rivets etc.(Once in a Year ) (a)SS Hood cleaning
Grease filters cleaning
Exhaust Blower of 3 HP
GI Ducting ( Approx )
112 HU Cafeteria
Servicing and cleaning of exhaust hoods along with grease filters with necessary chemical consumables with removal of oil, dust fumes inside and outside of hoods complete as required, Burning of ducting and blower, balancing of impeller, painting, replacements of nuts and bolts, rivets etc.(Once in a Year ) (a) SS Hood cleaning
Grease filters cleaning
servicing of Exhaust Blower of 3 HP
Remove unserviceable 3HP motor and take to workshop after removing the unserviceable winding with new suitable copper including changing bearings overhauling and testing,refixing as directed by Engr-In-Charge
Remove unserviceable 5HP motor and take to workshop after removing the unserviceable winding with new suitable copper including changing bearings overhauling and testing,refixing as directed by Engr-In-Charge
UNIVERSAL ENGINEERING
SRINIVASA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .