Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC GOSWAMI COLONY PO UDAYAN VIHAR DISTT KAMRUP ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC Validated (Lowest bidder) | |
| 2 | L2₹39.2 L+₹2.9 L (7.85%)Rejected-Finance F NO A1 APURBA ENCLAVE BRINDABAN PATH RUPNAGAR KAMRUP GUWAHATI ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | L2 | Rejected-Finance Not Validated (Other than lowest bidder) | |
| 3 | L3₹39.7 L+₹3.3 L (9.01%)Rejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Not Validated (Other than lowest bidder) |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
23 Nov 2023, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/MAINT OF EXTERNAL ELECTRIFICATION SYSTEM, DISTRIBUTUION LT PANELS WITH CONNECTED ITEMS, LIGHTING ARRESTORE, GODs ETC AND ALLIED SERVICES AND REPAIR/REPLACEMENT TO EXTERNAL WATER SUPPLY DISTRIBUTION SYSTEM WITH CONNECTED SERVICES AT OTHER THAN
2023_MES_625394_1
GE/GUW/30/8353 OF 2023-24
Open Tender
Civil Works
Item Rate
150 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹80,000
Yes
20 Jan 2024
27 Oct 2023
25 Nov 2023
27 Oct 2023
23 Nov 2023
10 Nov 2023
27 Oct 2023 - 3 Nov 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread soft soil complete all as specified and directed.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply and laying dry river sand cushioning for cable protection with a layer of 8cm deep before laying and 15cm after laying gently punned down to 10 cm on top of the cable as per SSR Part-I complete all as specified and as directed. (Note : Punned thickness shall be measured).
Supply and laying in trenches bricks common burnt clay, building brick, sub class B designation 75 old size bricks for cable protection, flat and width wise along the axis of trench all as specified and directed
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 400 sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 150 sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 120 sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 95 sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 70 sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 50 sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 25 sqmm x 3.5 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 16 sqmm x 4 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supply, Laying connecting, testing and commissioning of LT under ground cable of cross sectional area 10sqmm x 2 core XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade confiming to IS 7098, laid in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as specified and directed.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panel etc. MCCB, TPN (4 Pole), 630 Amps, 50kA breaking capacity with overload and thermal tripping feature with magnetic release , 415Volts AC, 50Hz, ICU = 100%, including certain addition or alteration if required at site complete all as specified and directed.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panel etc. MCCB, TPN (4 Pole), 400 Amps, 36 kA breaking capacity with overload and thermal tripping feature with magnetic release , 415Volts AC, 50Hz, ICU = 100%, including certain addition or alteration if required at site complete all as specified and directed.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panel etc. MCCB, TPN (4 Pole), 250Amps, 36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz, ICU = 100%, including certain addition or alteration if required at site complete all as specified and directed.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panel etc. MCCB, TPN (4 Pole), 160Amps, 36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz, ICU = 100%, including certain addition or alteration if required at site complete all as specified and directed.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panel etc. MCCB, TPN (4 Pole), 125 Amps, 36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz, ICU = 100%, including certain addition or alteration if required at site complete all as specified and directed.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panel etc. MCCB, 4 Pole, 100Amps, 36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz, ICU = 100%, including certain addition or alteration if required at site complete all as specified and directed.
Supplying and fixing in repair, connecting, testing and commissioning MCCB in panel etc. MCCB, 4 Pole, 63Amps, 36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz, ICU = 100%, including certain addition or alteration if required at site complete all as specified and directed.
Supplying, fixing, testing and commissioning on load changeover switch four pole of rated current of 63 amp capacity, 415 volts, 50 Hz confirming to IS : 13947 (Part-3), IEC:60947-3 in SS enclosure over existing location all as specified and directed. NOTE : Cost of minor addition, alteration, fabrication work if required at site to fix properly deemed to be included in the quoted rates.
Supply, fixing, testing and commissioning on load changeover switch four pole of rated current of 250 amp capacity, 415 volts, 50 Hz confirming to IS : 13947 (Part-3), IEC:60947-3 in SS encloser over existing all as specified and directed NOTE : Cost of minor addition, alteration, fabrication work if required at site to fix properly deemed to be included in the quoted rates.
Supply and fixing for power contactor, 4 pole with AC coil, 415 V, 50 HZ, 200 A and auxillary contact 2 No + 2NC complete all as specified and directed
Material and Labour for Boring/drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for insertion of GI pipe of 40 to 150mm bore for passing cable across the road (without cutting the road) complete all as specified and directed. (Note : GI pipe will be measured and paid separtely under appropriate items)
Supply and fixing in replacement for GI protection pipe light grade for cable protection incl all fittings laid in trenches or fixed on pole/walls with mild steel clamps, bolts, nuts and washers complete all as specified and directed for 50mm bore. (NOTE : Earth work reqd shall be measured and paid separately).
Material and labour for Restringing of existing four wire LT over head line including removing the existing binding wire and rebinding with new binding wire after tightening of overhead lines including disconnecting existing jumper and connections and reconnecting after tightning of conductor all as specified and directed. (Note:- Four wire run of conductor and two run of earth continuity wire in LT lines shall be measured as one length for payment purpose)
Material and labour for Restringing of existing Two wire LT over head line including removing the existing binding wire and rebinding with new binding wire after tightening of overhead lines including disconnecting existing jumper and connections and reconnecting after tightning of conductor all as specified and directed. (Note:- Two wire run of conductorand two run of earth continuity wire in LT lines shall be measured as one length for payment purpose)
Material and labour for stay assembly with accessories as shown in electrical plate No.1 of SSR Part-I complete with diameter of rod 20 mm. (Note:- loop type insulator, stay clamps, excavation and concrete will be measured and paid separately).
Material and labour for insulated synthetic rubber mat suitable for voltage upto 3.3 KV of size 2m x 1m x 2mm for electical purpose as per IS 15652-2006 suitable for electrical shock safety including taking old worn out insulated mat from various locations of E/M installations all as specified and directed.
Material and labour for cutting the burnt out aluminium lugs and relugging of HT/LT cable in cable end box of transformer on switches including cutting existing lugs suitable for cable of size 50 to 150 sqmm and reconnection after repair work and testing etc complete all as specified and directed. Note: The cost of the liftings of cable whereas required for relugging is deemed to be inclusive in the unit rates quoted by the tenderer against that item all as specified and directed.
Material and labour for straight through joints (epoxy type) for LT PVC / XLPE insulated armoured aluminium conductor cable including jointing and testing etc for the size 25 sqmm to 50 sqmm 4 core / 3.5 core all as specified and directed Note : Cutting of faulty cable/ joint is deemed to be included in the above quoted rates.
Material and labour for straight through joints (epoxy type) for LT PVC / XLPE insulated armoured aluminium conductor cable including jointing and testing etc for the size 70 sqmm to 120 sqmm 3.5 core all as specified and directed Note : Cutting of faulty cable/ joint is deemed to be included in the above quoted rates.
Material and labour for straight through joints (epoxy type) for LT PVC / XLPE insulated armoured aluminium conductor cable including jointing and testing etc for the size 150 sqmm to 185 sqmm 3.5 core all as specified and directed Note : Cutting of faulty cable/ joint is deemed to be included in the above quoted rates.
Supplying and fixing mild steel chequered plate Fe-410-W (gde-E-250) Quality -A, 6 mm thick square cut or notched , forming holes without any attachment as duct covering size and length as approved incl primer painting all as specified and directed.
Material and labour for steel tubular swaged poles type 410 SP-31 (9 Mtr long) complete with CI base plate and finial taper plug, bolts, nuts and screws andfixed into PCC foundation duly painted with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces and making strip 150mm wide upto 1.5m (above PCC copies) by black, yellow paint in attenate layers and pole Nos including taking out old complete including demolition of concrete foundation all as specified and directed. Note:- (i) Excavation, Earth & PCC work will be measured & paid separetely. (ii) All other accessories and work deemed to be included in quoted rates. (iii) the poles shall confirm to IS-2713 & each component of the pipe shall be ISI marked and confirm to IS-1161.
Material and labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation of pole/ stay/ angle/ pipe complete all as specified and directed.
Material and labour for PCC 1:2:4 type B0 using 12.5mm graded for pedestal coping including necessary formwork finished even and smooth using extra cement complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for foundation of pole/ stay/ angle/ pipe complete all as specified and directed.
Supply , install, testing and commissioning of floor mounted LT OUTDOOR feeder pillar box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick with CPRI Approved CRCA steel sheet of Size ( 0.9 x 0.9 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed . INCOMER (a) Supply and fixing MCCB 4 pole 415 Volts with microprocessor controller of breaking capacity of 16 KA of 100 Amps with Fixed thermal and Fixed magnetic setting- 01 Nos BUSBAR :-(Outgoing) (i) Aluminium bus bar 200 Amps , supported on non hygroscopic fibres and brass screws for mounting -04 Nos INDICATING DEVICES (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos (b ) Supply and fixing Digital Ammeter Meter of size 100mmX100mm for 0-300 A display , including CT having CTR 200/5 - 01 Nos & Digital Voltmeter 0-500 Volts , SIF 96 - 01 Nos
Supply , install, testing and commissioning of floor mounted LT OUTDOOR feeder pillar box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick with CPRI Approved CRCA steel sheet of Size ( 1.5 x 1.0 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed .(Main panel for various Billets) BUS BAR:- (i) Aluminium bus bar 400 Amps , supported on non hygroscopic fibres and brass screws for mounting -04 Nos. (ii) INCOMMER:- (a) Supply and fixing MCCB 4 pole 415 Volts with mocroprocessor controller of breaking capacity of 36 KA of 160 Amps with Fixed thermal and Fixed magnetic setting- 01 Nos (iii) INDICATING DEVICES:- (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos (b ) Supply and fixing Digital Ampere Meter of size 100mmX100mm for 0-300 A display , incl CT having CTR 200/5 - 01 Nos & Digital Voltmeter 0-500 Volts , SIF 96 - 01 Nos (iv) OUTGOING FEEDERS:- (a) Supply and fixing MCCB of 4 pole , 415volts of capacity 63 amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting - 06 Nos
Supply and fixing for vertical TPN 4 way with provision and including of MCCB of 63 Amp 4 Pole and provided with CRCA sheet steel powder coated,double door ready to use DBs provided with insulated vertical phase bus bar, neutral bar, earth bar, sticking saddle, colour coded interconnecting wire set, cable ties, blanking plates etc all as specified and directed.
Material and labour for repair/ maintenance of LT panel door by replacement of hinges and locking arrangement including necessary welding/ nuts, bolts, washers as per existing size/ type complete all as specified and directed. (Note: One side door will be measured & paid as one job).
Material and labour for applying two coats of syntheic enamel paint (of approved shade) on external sufraces LT Panel (exposed surface area not less than 1.5Sqm) including necessary preperation of surfaces, and writing Substation No from which FPB Charged and Accomodations whereto are Supplied from Feeder Pillar Box complete all as specified and directed.
Supplying and fixing Cable Junction Boxes IP 66 “halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) size 200 x 160 x 98 mm suitable for 16/25 sq.mm fixed to pole /wall with suitable FI clamp 20X3 mm nuts , bolts and washers incl provision of 01 No miniature circuit breaker (MCBs) single pole , 240 volts 10 KA 6 Amps and incl suitable capacity aluminium bus bar , complete all as specified and as directed.
Material and labour for Making connection of PP-R distribution branch with PP-R main of sizes 16 to 40mm outer dia by providing and fixing tee as per IS15801 including cutting and making fusion joint etc all as specified and as directed.
Material and labour for Making connection of PP-R distribution branch with PP-R main of sizes 50 to 75mm outer dia by providing and fixing tee as per IS 15801 including cutting and making fusion joint etc all as specified and as directed.
Supply and fixing PP-R Ball valves (brass insert) , high pressure, with polythene float and flynut complete, screwed for iron /PPR pipe(32mm outer dia) or brass ferrule and fixed all complete all as specified and as directed. .
Supply and fixing PP-R Ball valves (brass insert) , high pressure, with polythene float and flynut complete, screwed for iron /PPR pipe(25mm dia) or brass ferrule and fixed all complete all as specified and as directed.
Supply and fixing in repair including taking out existing pipe of any type for 3- layer PP-R (Polypropylene random copolymer) pipes 110 mm outer dia ,SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all fittings PP-R plain & brass threaded type polypropylene random sockets and bends as required at site laid in trenches/floor at places where directed complete all as specified and directed.
Supply and fixing in repair including taking out existing pipe of any type for 3- layer PP-R (Polypropylene random copolymer) pipes 90 mm outer dia ,SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random sockets and bends as required at site laid in trenches/floor at places where directed complete all as specified and directed.
Supply and fixing in repair including taking out existing pipe of any type for 3- layer PP-R (Polypropylene random copolymer) pipes 63 mm outer dia ,SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random sockets and bends as required at site laid in trenches/floor at places where directed complete all as specified and directed.
Supply and fixing in repair including taking out existing pipe of any type for 3- layer PP-R (Polypropylene random copolymer) pipes 50mm outer dia ,SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random sockets and bends as required at site laid in trenches/floor at places where directed complete all as specified and directed.
Supply and fixing in repair including taking out existing pipe of any type for 3- layer PP-R (Polypropylene random copolymer) pipes 32mm outer dia ,SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random sockets and bends as required at site laid in trenches/floor at places where directed complete all as specified and directed.
Supply and fixing in repair 63mm outer dia PP-R Gate valve ( brass insert)complete all as specified and as directed.
Supply and fixing in repair50mm outer dia PP-R Gate valve ( brass insert)complete all as specified and as directed.
Supply and fixing in repair32mm outer dia PP-R Gate valve ( brass insert)complete all as specified and as directed.
Supply and fixing in repair gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed suitable for 50 mm bore pipe complete all as specified and as directed .
Supply and fixing in repair gun metal gate valve, with iron wheel head, screwed both ends for iron pipe and fixed suitable for 25 mm bore pipe complete all as specified and as directed .
Supply and fixing in repair 100 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etc and testing complete all as specified & directed.
Supply and fixing in repair 80 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etc and testing complete all as specified & directed.
Supply and fixing in repair 150 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etc and testing complete all as specified & directed.
Material and labour for 100 mm bore GI tubing medium grade in trenches/ floor/ pillar and connection in old or news position as per site requirement including fittings like socket/ union/ tee/ reducer Nipple etc complete all as specified and directed.
Material and labour for 80 mm bore GI tubing medium grade in trenches/ floor/ pillar and connection in old or news position as per site requirement including fittings like socket/ union/ tee/ reducer Nipple etc complete all as specified and directed.
Material and labour for 50 mm bore GI tubing medium grade in trenches/ floor/ pillar and connection in old or news position as per site requirement including fittings like socket/ union/ tee/ reducer Nipple etc complete all as specified and directed.
Material and labour for 25 mm bore GI tubing medium grade in trenches/ floor/ pillar and connection in old or news position as per site requirement including fittings like socket/ union/ tee/ reducer Nipple etc complete all as specified and directed.
SWASTIKA TELESERVICES
S. R. TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .