Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.0 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹31.9 L+₹2.1 L (7.04%)Rejected-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹42.6 L+₹12.8 L (42.9%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L-3 | Rejected-AOC L-3 |
Tender Value
₹42.2 L
EMD Value
₹84,400
Closing Date
6 Dec 2023, 6:00 pmClosed
GE I RnD Delhi
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR MAINTENANCE OF CENTRAL AC PLANT, VRF SYSTEM AND COOLING APPLIANCES IN DIPAS AND DIPR UNDER ZONE B AT KWC AND REPAIR MAINT OF STREET BUILDING SECURITY LIGHT AND OTHER CONNECTED WORKS AT ZONE B AREA UNDER GE I RND DELHI
2023_MES_627510_1
GE/RND-67/DLI/2023-2024
Open Tender
Civil Works
Item Rate
270 days
Delhi
Class-D, Cat-b(i), c(i)
2 documents required · 2 mandatory
₹500
GE I RnD Delhi
₹84,400
Yes
13 Jan 2024
8 Nov 2023
8 Dec 2023
8 Nov 2023
6 Dec 2023
22 Nov 2023
Amount
M&L for Servicing of VRF inverter split type 3 phase AC of capacity 14 TR. of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed Note:- Any unserviceable items need to be replaced & gas charging etc shall be measured and paid seperately under respective items.
Isolating/Disconnecting and dismantling of UNSV compressor 14TR capacity from VRF type AC unit and supply and fixing with new hermatically sealed scroll compressor of 8 HP cpacity including leak tesing and pressure testing for 24 hours and gas changing with R-22 refrigarent including testing with Nitrogen gas etc complete all as specified and directed.
Taking down the existing UNSV expansion valve supply and fixing new thermostatic expansion valve for 8 HP capacity compressor complete all as specified and directed.
M&L in replacement Microprocessor Magnum Controller alongwith Software, installation and controlling arrangement including thimbles control wire etc suitable for 50TR AC Plant of Voltas complete all as specified and directed.
S&F in replacement filter from AHU small & large both complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of auto air vent valve of 15 mm dia complete all as specified and directed.
M&L in replacement hot water generator of capacity 30 KW in four banks complete with one slave bank controlled by semi conductor rectifier & other necessary controls, electrical panels etc complete all as specified and directed.
S&F in replacement including testing of chiller water flow valve with electric control and other works as required at site to make the system functional including welding as required at site complete all as specified and directed.
M&L for servicing/ descaling of hot water generator upto 30KW 3 phase 415 Volts including replacement of burnt heaters and calibration testing of all functional with including replacement of any defective parts complete all as specified and directed.
M&L for Cleaning of the evaporator coil of 50 TR capacity central air conditioning plant with cleaning agent by forced feed method to remove the unwanted dust formed over the cooling coil fins without disturbing the mounting of the coils and greasing to the AHU blower bearing and tightening of all fasteners etc complete all as specified and directed. Note :- (The descaling and cleaning works to be carried out by authorised skilled person by the service dealer or from the Manufacturer)
S&F in replacement thermostatic expansion valve suitable for 50 TR capacity central air conditioning plant including cutting and bracing complete all as specified and directed. Make: Sporlan/ Indfos/ Danfos
M&L for Dismantling the compressor of 50 TR from installed position after disconnecting the suction and discharge refrigerant line, open the compressor and carry out the repairs/ replacement of unserviceable parts, setting of valve reeds, valve plates, bearings, loading and unloading mechanism, pistons with rings, oil seals, oil pumps etc after carrying out necessary lathe work for grinding and polishing the worn out seatings/ housing of the compressor body and assembling with essential minor parts i.e. split pins, nuts, bolts, washers, rubber rings etc and fixing in its position including testing for proper functioning complete all as specified and directed.
M&L for pumping down the refrigerant for re use from the gas line to the chillar unit, removing the existing insulation at the shell and tube chiller and carefully dismantling the refrigerant pipe lines, chilled water circulation pipe lines with valves on both inlet and outlet side. Cut open the chiller in a dust free environment with proper tools and equipments and replacement of the damaged existing copper gas pipe line with new annealed copper pipe line of the existing diameter with minimum 0.5mm thick fixing in original position including necessary brazing/ welding and fixing for smooth functioning. Re-assembling the chiller unit with proper Air tight sealed for leak proof by ensuring filling with Nitrogen gas for 72 hours pressure test and covered the complete chiller with nitrate insulation with minimum 19mm thick before connecting, testing and commissioning complete all as specified and directed. Note:- Opening and assembling should be done by the authorised dealer and all the spares should be provided through OEM.
M&L for disconnecting, dismantling and strip opening of the existing air handling unit of any description and in any position and of capacity of 50 TR for overhauling and servicing, including taking out existing shaft, blower drum, pulley and de-humidifier pump etc of air handling unit, checking thoroughly serviceability of the parts, fixing the serviceable parts in positiion, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing of the air handling unit on full load for its smooth and trouble free operation complete all as specified and directed.
M&L for disconnecting & dismantling of existing unserviceable cooling tower, FRP type 50 TR capacity of any description & in any position including dimantling all old connected part/ filters, like motor, FRP casing basin, PVC filling, MS/GI pipe line, sluice valve, stop valve, steel structure frame etc. Servicing/ Overhauling, cleaning, oiling/ greasing and fixing of serviceable parts with new parts, reassembling the cooling towers and connected parts/ items fixed in position for connected to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-charge.
M&L for overhauling of pump and motor 7.5 to 10HP capacity by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable / damaged part like impeller, bearing, bush, seal, shaft, coupling, machine work etc and reconnecting back and testing complete all as specified and directed.
M&L for overhauling of pump and rewinding of electric motor with super enamelled copper winding wire of existing gauge of capacity 5 to 7.5 HP by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable/damaged part like impeller, bearing, bush, seal, shaft, coupling, machine work etc and reconnecting back and testing complete all as specified and directed.
M&L for descalling and cleaning of 50 TR condenser water cooled by circulating the diluted chemical HCL by forced feed method not less than 6hrs duration by opening of the end covers of the condenser brushing the tubes thoroughly,re-fixing back the end cover of the condesers with 3mm thick rubber gasket and testing complete to maintaining desired discharged pressures for water cooled condenser complete all as specified and directed.
M&L for charging of Refrigerant R-407C complete including testing after completion complete all as specified and directed.
M&L for charging of Refrigerant R-410 complete including testing after completion complete all as specified and directed.
Supply & filling of compressors oil with testing for complete all as specified and directed.
M&L for Finding out leakage in the system, leakage repair including brazing cost, Nitrogen Testing and recommissioning of 50 TR water cooled Chiller complete all as specified and directed.
M&L for rewinding of AHU motor with super enamelled copper winding wire of existing gauge including testing complete all as specified and directed.
M&L in replacement Butterfly Valve 150mm dia including the application of nitrile rubber insulatioin over the valves complete all as specified and directed.
M&L for fixing all the accessories including Butterfly Valve 100mm dia including the application of nitrile rubber insulatioin over the valves complete all as specified and directed.
M&L in replacement V belt of size A42 complete all as specified and directed.
M&L in replacement V belt of size A43 complete all as specified and directed.
M&L in replacement V belt of size A46 complete all as specified and directed.
M&L in replacement V belt of size A48 complete all as specified and directed.
M&L iin replacement V belt of size A49 complete all as specified and directed.
S&F in repair water pressure gauge along with stop cock and fixing arrangement suitable for water pressure 0-16/20 kg/sq cm complete all as specified and directed.
S&F in repair industarial type thermometer of range 0-50 degree centigrade for AC plant as per sample complete all as specified and directed.
S&F in repair suction pressure gauge suitable for suction pressure 0-250 PSI complete all as specified and directed.
S&F in repair discharge pressure gauge suitable for discharge pressure 0-500 PSI complete all as specified and directed.
S&F in repair timer electronic type complete all as specified and directed.
S&F in repair single phase preventer complete all as specified and directed.
S&F in repair power contractor of MNX - 25 complete all as specified and directed.
S&F in repair of LP switch complete all as specified and directed.
S&F in repair of HP switch complete all as specified and directed.
S&F in repair of refrigerant copper pipe 15mm dia & wall thickness 1.24 mm complete all as specified and directed.
S&F in repair of refrigerant copper pipe 12 mm dia & wall thickness 1.24 mm complete all as specified and directed.
M&L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- Any unserviceable items need to be replaced/gas charging etc shall be measured & paid seperately under respective items.
All as per item Ser No. 42.00 above but for split type AC/Inverter type AC 1.5/2.0/4.1 Ton
M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of existing Make and required Size to suit existing AC complete all as specified and directed.
All as per item Ser No. 44.00 above but AC (Window/Split Type). 2.0 TR Capacity.
M&L for Rewinding of Fan Motor of AC 1.5/2 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and directed.
M&L in replacement Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity complete all as specified and directed.
M&L in replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
M&L in replacement Air Filter suitable of AC (Split type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
M&L in replacement Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make complete all as specified and directed.
M&L in replacement Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make complete all as specified and directed.
M&L in replacement Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity complete all as specified and directed.
M&L in replacement Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed.
M&L Fan Motor in replacement Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed.
M&L in replacement Front Plastic Grill (as per Sample) of AC (Window type) 1.5 TR/2.0 TR Capacity all as per existing and complete all as specified and directed.
M&L in replacement Front Plastic Grill for inner unit (as per Sample) of AC (Split type) 1.5 TR/2.0 TR Capacity all as per existing complete all as specified and directed.
M&L in replacement Runner for air blower motor of AC (split type) AC 1.5/2.00TR capacity (As per sample or as per site requirement) complete all as specified and directed.
M&L in replacement Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) complete all as specified and directed.
M&L in replacement Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity complete all as specified and directed.
M&L in replacement Strainer with Capillary Tube of AC Window/ Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and directed.
M&L in replacement Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and directed.
S&F in replacement cooling coil suitable for window type room AC 1.5/2 ton as per sample complete all as specified and directed.
S&F in replacement Condensing coil suitable for window type AC 1.5/2 ton complete all as specified and directed.
S&F in replacement Condensing coil suitable for split type AC of capacity 2 ton complete all as specified and directed.
S&F in replacement cooling coil suitable for split type AC up to capacity 2 ton complete all as specified and directed.
S&F in replacement Indoor unit suitable for 1.5 TR split type AC of existing make & description complete all as specified and directed.
S&F in replacement outdoor unit suitable for 1.5 TR split type AC with compressor as per existing make and description complete all as specified and directed.
S&F in replacement Indoor unit suitable for up to 2 TR split type AC as per existing description complete all as specified and directed.
S&F in replacement outdoor unit suitable for up to 2 TR split type AC with compressor complete all as specified and directed.
S&F in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed.
All as per item Ser No. 72.00 above but of split/ window type AC capacity 2.0 Ton.
Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop for any type of defect and back after repair from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and directed. Note:-Spare parts required to be replaced shall be measured and paid separately under relevant items.
All as per Item Ser No. 74.00 above but AC 2.0 TR Capacity (Window/Split Type).
M&L in replacement PCB with remote for window type AC up to 2 Ton capacity complete all as specified and directed .
M&L in replacement PCB with remote for Split type AC 2 Ton capacity complete all as specified and directed .
M&L in replacement PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity complete all as specified and directed .
Taking down defective/ unserviceable PCB & motherboard of AC 1.5 TR Capacity Split Type, transportation from MES Store Yard/Site to Workshop and back after complete repair of PCB and motherboard for smooth functioning including re-fixing and testing for proper functioning of AC complete all as specified and directed.
Taking down defective / unserviceable PCB & motherboard of AC 2 TR Capacity Split Type, transportation from MES Store Yard/Site to Workshop and back after complete repair of PCB and motherboard for smooth functioning including re-fixing and testing for proper functioning of AC complete all as specified and directed.
M&L in replacement Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) complete all as specified and directed.
S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete complete all as specified and directed.
S&F in replacement gas charging pin valve complete all as specified and directed.
Taking out window type AC of any capacity complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit and re-connection and testing complete all as specified and directed.
Taking out split type AC of any capacity complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit including re-connection and testing complete all as specified and directed.
Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All as per ser item Ser No. 86.00 above but R- 32 for split type AC up to 2 TR capacity.
All as per item Ser No 86.00 above but cassatte type AC upto 4 TR capacity.
All as per item Ser No 86.00 above but VRF unit 8 TR capacity.
S&F in replacement of casing of window type AC including company fitted condensing & cooling coil complete including PCB except compressor complete all as specified and directed.
M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
All as per item Ser No. 91.00 above but 1/2".
S&F in replacement compressor shut off valve 3/8" for split AC up to 2 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2 ton capacity complete all as specified and directed.
S&F in replacement of electrolyte grade copper tubing of size 1/4" dia, having wall thickness 0.9 mm suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
All as per item Ser No. 95.00 above but size 1/2" dia, having wall thickness 1.24 mm
All as per item Ser No. 95.00 above but size 3/8" dia having wall thickness 1.65 mm
All as per item Ser No. 95.00 above but size 5/8" dia having wall thickness 1.24 mm
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement of synthetic rubber foam for insulation for refrigerant copper piping of existing size 1/4" to 5/8" internal dia for split type AC upto 2 Ton capacity complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler of existing make and description including bracing the suction and discharge lines complete all specified and dircted.
S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler of existing make and description including bracing the suction and discharge lines complete all specified and dircted.
S&F in replacement AC stand suitable for out door split AC unit up to 2 ton capacity made out of MS angle 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building including 02 Coats of Syntheic enamal paint over 01 Coat of Red Oxide Primer complete all as specified and directed . Note:- Dimensions & design of stand shall be as approved by Engineer-in- Charge.
S&F in replacement reverse valve system made out of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and directed.
Taking down Defective Water Cooler 40/80 litre Capacity, Transportation from MES Store Yard/Site to Workshop and back for any type of defect including re-fixing /reinstall -ing, Testing, connecting the same after complete repair for smooth functioning including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and directed.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement push cock 15 mm bore chromium plated, heavy duty, suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paid, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed.
S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed.
S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, replacing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note:- Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint/inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed. Note :- The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of desert cooler sub mersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and directed.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed.
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and directed.
S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed.
S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed.
S&F in replacement front grill made out of Mild Steel complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
S&F in replacement of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with one coat of red-oxide primer & 2 coat of synthetic enameled paint complete with fixing of all spare complete all as specified and directed.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide primer & 2 coat of synthetic enameled paint complete with fixing of all spare complete all as specified and directed.
S&F in replacement of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specified and directed.
S&F in replacement wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler complete all as specified and directed.
M&L in replacement of aluminium multi wing Fan blade, best quality as per existing type and size suitable for desert cooler complete all as specifed and directed
S&F in replacement thermostate of approved make and suitable size & model for the following :-
Auto 'D' thermostate No 1027 with knob for Deep freezer / refrigerator or equivalent
Thermostate No 2064 with knob for water cooler or equivalent
S&F in replacement relay kit (OLP + LMS relay or box type) as per sample for refrigerator complete all as specified and directed.
S&F in replacement relay kit as per sample for water cooler, No 412Y/512Y or equivalent complete all as specified and directed.
S&F in replacement potential box type relay/PTC relay of suitable model for split type AC/deep freezer complete all as specified and directed.
S&F in replacement knobs for AC/desert cooler of any capacity complete all as specified and directed.
M&L in replacement cooling coil of existing size/ model for refrigerator complete all as specified and directed.
M&L in replacement condenser of existing size/ model for refrigerator complete all as specified and directed.
M&L in replacement of broken freezer door complete with casing and lock nut as per sample for refrigerator of any capacity complete all as specified and directed.
M&L in replacement of vegetable tray complete suitable for existing model of refrigrator of any capacity complete all as specified and directed.
M&L in replacement of chiller tray complete suitable for existing model of refrigerator of any capacity complete all as specified and directed.
M&L in replacement of metal shelf powder coated suitable for existing model of refrigerator of any capacity complete all as specified and directed.
M&L in replacement of bulb pintype/thread type suitable for existing model of refrigerator of any capacity complete all as specified and directed.
M&L in replacement of broken door panel gasket complete suitable for existing model of refrigeratior of any capacity complete all as specified and directed.
M&L in replacement of burnt out condenser fan motor, single shaft suitable for any capacity, single phase, 230 V , AC, for water cooler complete all as specified and directed.
M&L for checking of drain water tray for leakage & getting the same repaired by soldering all the sides of the tray including making proper provision for fitting of grating to the tray to make it functional complete all as specified and directed.
M&L in replacement stop cock, 15 mm dia brass chromium plated, heavy duty for water cooler complete all as specified and directed.
S&F in replacement fan blade (As per sample) for water cooler/ deep freezer of any capacity complete all as specified and directed.
S&F in replacement PVC float valve 15mm bore for water cooler of any capacity complete all as specified and directed.
S&F in replacement PVC connection 15mm size with PTMT nuts of following sizes:-
S & F in replacement PVC flexible drain outlet pipe 32/40mm dia complete for water cooler of any capacity complete all as specified and directed.
M&L M. S work as in repair/replacement of bottom portion of the water cooler of any make & capacity with MS angle iron of suitable size as per existing, including welding/brazing with MS sheet 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc including 02 Coats of Syntheic enamal paint over 01 Coat of Red Oxide Primer complete all as specified and directed.
M&L for replacement of old wornout/burnt wiring of water cooler/ deep freezer by using copper conductor wire PVC sheathed of existing size and length complete all as specified and directed.
All as per item Ser No 153.00 above but for split type / window A/C of any capacity .
S&F in replacement fan blade (As per sample) for Desert Cooler of any capacity complete all as specified and directed.
S & F in replacement drain outlet PVC pipe 20mm dia from indoor unit to nearest suitable drain outlet for split type AC of any capacity complete all as specified and directed.
S&F in replacement door handle as per sample of Deep Freezer complete all as specified and directed.
S&F in replacement door gasket of Deep Freezer of any capacity complete all as specified and directed.
M&L in replacement air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter's size and shape, as directed for 1.5/2 TR capacity of split type AC complete all as specified and directed.
S&F in replacement MCB, SP 6- 32 Amps,10 KA ,230 V, 'C'series complete all as specified and directed.
S&F in replacement MCB, SPN, 20-40 Amps,10 KA ,230 V, 'C'series complete all as specified and directed.
S&Fin replacement MCB TPN, 415 Volts, 40/63 Amps,10 KA ,230 V, 'C'series complete all as specified and directed.
M&L for servicing the deep freezer unit completely for trouble free working and satisfactory performance by means of cleaning each part of the machine carefully, greasing/oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and pressure air through blower and cleaning the machine for better working complete all as specified and directed.
M&L in replacement for replacement of caster wheels (set of four) for Air cooler/desert cooler of any size and capacity complete all as specified and directed.
M&L in replacement for replacement of switch assembly for Air cooler/desert cooler of any size and capacity complete all as specified and directed.
M&L for removing of old unserviceable stabilizer of capacity 4KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility complete all as specified and directed.
M&L for removing of old unserviceable stabilizer of capacity 5 KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility complete all as specified and directed.
M&L in replacement voltage stablizer 5 KVA capacity alongwith complete spares of stablizer such as control transformer, main transformer, voltmeter, relay, control board, etc and fiixing at the same position including electrical connection complete and checking it for its workablility complete all as specified and directed.
M&L in replacement voltage stabilizer of capacity 4 KVA alongwith complete spares of stablizer such as control transformer, main transformer, voltmeter, relay, control board, etc and fiixing at the same position including electrical connection complete and checking it for its workablility complete all as specified and directed.
Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnection electric connection and removing from site for rewinding/ overhauling/ servicing of fans and fixing the same in eixsting position or as directed by engineer-in-charge with electric connection and testing complete all as specified and directed
M & L for overhauling of ceiling fan/pedestal/exhaust/table/air circulating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
M&L in replacement of Fan blade of existing make, made out of iron body of size 230 mm to 300 mm, complete all as specifed and directed
M&L in replacement of exhaust shutter with frame of existing make, made out of iron body of size 230 mm to 300 mm, complete all as specifed and directed
M&L in replacement of exhaust fan moter of existing make, made out of iron body of size 230 mm to 300 mm, complete all as specifed and directed
M&L in replacement of Fan blade of existing make made out of iron body of size 380 mm to 450 mm, complete all as specifed and directed
M&L in replacement of exhaust shutter with frame of existing make made out of iron body of size 380 mm to 450 mm, complete all as specifed and directed .
M&L in replacement of exhaust fan moter of existing make, made out of iron body of size 380 mm to 450 mm, complete all as specifed and directed
S&F in repairs PVC fresh air fan 250mm sweep complete all as specified and directed.
S&F in repairs PVC fresh air fan 200mm sweep complete all as specified and directed.
S&F in repair fan Condenser 2.5 mfd, 230 Volts complete all as specified and directed.
S&F in repair existing fan Condenser 4 mfd, 230 Volts complete all as specified and directed.
S&F in replacement fan motor assembly complete including double bearing, copper winding with metal plate top & bottom side suitable for 1200 mm sweep of existing size and at any location complete all as specified and directed.
S&F in replacement ceiling fan blade (set of 3), suitable for 1200 mm sweep of existing make complete all as specified and directed.
S&F in replacement anchor bolt & nut of 8 mm dia of the geyser for fixing on wall in a suitable way and making good the distrubed area complete all as specified and directed.
S&F in repair PVC box with 06 Amps switch and socket complete duly fixed on wall including connection with 2x 1.5 sq mm copper conductor wire and 1x1.5 sq mm earth wire in and including PVC caping/casing on surface / recessed and length as per site requirement complete all as specified and directed. Note :- Wire & PVC casing/caping shall be measured & paid separately under relevant items.
S&F in repair PVC box with 06/ 16 Amps switch and socket complete duly fixed on wall including connection with 2x 2.5 sq mm copper conductor wire and 1x2.5 sq mm earth wire in pvc/ caping casing on surface / recessed and length as per site requirement complete all as specified and directed Note :- Wire & PVC casing/caping shall be measured & paid separately under relevant items.
Supply only Self adhesive PVC electrical Insulation tape 7 mtr long, ISI mark with superior quality complete all as specified and directed.
Supply only the following spare parts complete all as specified and directed :-
Bearing 6200 to 6203 ZZ, Make - SKF/NBL
Conductor Terminal 3 way Bakelite
Brass gun metal bushing suitable of size 1200/1400mm sweep ceiling fan.
S&F in replacement canopy for ceiling fans (Set of two) complete all as specified and directed.
S&F in replacement MS clamp with rubber reel, nuts, bolts, split pin etc. suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
M&L in replacement of burnt winding of following fans, rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete and refixing the fan at positions complete all as specified and directed :-
Ceiling fan 1200/1400mm sweep working on 230 volts AC supply
Exhaust fan 250/300/450 mm sweep working on 230 volts AC supply
Wall mounting/Padestal Fan of 230/450 mm size,working on 230 volts AC supply
S&F in replacement down rod for ceiling fan made out of GI pipe medium grade 15mm dia with fan clamps incl drilling, cutting, threding etc all as directed for ceiling fan 1200/1400 sweep of following sizes:-
2 ft long
3 ft long
4 ft long
Taking down geysers carrying to workshop for leakage repairing , servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for :- Note:- Heating element, geyser tank, thermostat, indicator lamp & thermal cutout etc shall be measured and paid separately as "supply only".
25 liters capacity
50 liters capacity
M & L in replacement of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection complete all as specified and directed.
Supply only Heating element triangle/round type 1.5KW complete all as specified and directed.
All as per item Ser No. 191 above but capacity 2KW.
Supply only thermostate as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
Supply only Indicating lamp (red/green/yellow) complete suitable for 25/50 liters capacity geyser complete all as specified and as directed.
S&F in replacement PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 45/60cm long for cold water as per requirement complete all as specified and as directed
S&F in replacement PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 45/60cm long for hot water as per requirement complete all as specified and as directed
S&F in repairs PVC flexible three core copper 23/0.0076 size complete all as specified and directed.
S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade from socket/switch to geyser complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all all as specified and directed.
S&F in replacement metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
S&F in replacement multi core flexible copper conductor PVC insulated and sheathed cables 2 core, 0.75 Sqmm, 1100Volt complete all as specified and directed.
S&F in replacement of Room Heater 2900 Watt Suitable for 11 Fin,weight 18 Kg with fan complete all as specified and directed.
S&F in replacement of shut off valve as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
S&F in replacement of Thermo insulation glass wool as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
S&F in replacement of water connection CP for inlet & outlet (Hot & Cold) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
Supply and fixing of geyser assembly 6/9 holes suitable for 25/50 ltrs with existing brand/ ISI marked and all connected items complete all as specified and directed.
S&F in repalcement metal enclosures with clad socket & plug top 3 pole and earth, including of MCB SP 25 Amps 240 volts complete all as specified and directed.
S&F in repair IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules suitable for accommodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces complete all as specified and directed. Note:- MCCB 100 Amps 4 pole 16 KA as incomer will be measured and paid seprately in relevant item.
S&F in repair IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 8 way, 24 modules suitable for accommodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces complete all as specified and directed. Note:- MCCB 100 Amps 4 pole 16 KA as incomer will be measured and paid seprately in relevant item.
S&F in repair IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 12 way, 36 modules suitable for accommodating upto 160 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed complete all as specified and directed. Note:- MCCB 160 Amps 4 pole 25 KA as incomer will be measured and paid seprately in relevant item.
S&F in repair, IP-43 ,MCB DB 4 way ,double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces complete all as specified and directed.
S&F in repair, IP-43 ,MCB DB 8 way ,double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing (Make- Legrand or equivalent in ABB/L&T/ Schenider)
S&F in repair, IP-43 ,MCB DB 12 way ,double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing (Make- Legrand or equivalent in ABB/L&T)
M & L in replacement Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 4 x 10 Sqmm, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 1x10 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid, non metallic, PVC, heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall as per site requirement etc and connected to common earth dolly including all cutting / chases etc in any type of wall, making good as per existing description of the disturbed surfaces of wall to match the existing complete all as specified & directed. Note:-One meter of conduit along with 4x10 sq mm wire and 1x10 sq mm earth wire shall be measured as one unit length.
M & L in replacement Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 4 x 06 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 1 x 6 Sqmm nominal cross sectional area, with two single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic, heavy duty, PVC, heavy duty PVC conduit of white/ ivory colour and its accessaries, ISI marked of suitable size, concealed in wall as per site requirement etc and connected to common earth dolly including all cutting / chases etc in any type of wall, making good to the disturbed surfaces of wall to match the existing complete all as specified & directed. Note :- One meter of conduit along with 4x6 sq mm wire and 1x 6 sq mm earth shall be measured as one unit length.
M & L in replacement Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 2 x 6 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 1 x 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid, non metallic, PVC conduit, heavy duty white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall and connected to common earth dolly including all cutting / chases etc in any type of wall , making good of walls the disturbed surfaces to match the existing complete all as specified & directed. Note:-One meter of conduit along with 2x6 sq mm wire and one 6 sq mm earth wire shall be measured as one unit length.
M&L in replacement for submain wiring with 2 run 4 Sqmm cable PVC insulated copper conductor multi - stranded FRLS cable drawn through and including PVC non metallic, rigid, heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall as per site requirement including one run of 4 Sqmm single stranded copper conductor cable PVC insulated, unsheathed for earth continuity, connected to common earth dolly including necessary cutting /chases and making good to disturbed surfaces as per existing complete all as specified and directed. Note :- Note:-One meter of conduit along with 2x6 sq mm wire and one 4 sq mm earth wire shall be measured as one unit length.
Material and Labour in replacement earthing complete with copper plate electrode 600mmx600mmx3.15mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper earth strip 20x3mm by means of nuts, bolts and washers. Copper strip laid in 40mm dia, light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) complete all as specified and directed and as shown in electrical plat No. 03 of SSR Part-I with following:- (a) Copper strip 20x3mm upto 7.5 Metre. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars, 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
S&F in repair 20mm x 3 mm copper strip including 40 mm dia GI pipe, light grade from earth electrode, including connection with brass nut, bolt, spring washer on surface or in recess for connections etc as required complete all as specified and directed. Note :- Excavation and earthwork required for this items shall be measured and paid seperatly in respective items.
Material and Labour in replacemnet earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) complete all as sepcified and shown in Electrical plate No. 3 of SSR Part I and testing with following:- (a) GI strip of size 25mm x 4mm upto 7.5 Metre. (b) Watering pipe GI, light grade, 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 using 20 mm graded stone aggergate exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.Angle iron frame made of 40x40x4 mm angle iron for 30x30 cm PCC pit for holding the pit cover.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed . Note :- Excavation and earthwork required for this items shall be measured and paid seperatly in respective items.
Material and Labour in replacement for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron wire 4mm dia by means of Copper nuts, bolts and washers. GI wire laid in 20mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire 4 mm dia up to 7.75 Metre. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick, 1:2:4 type B1 using 20 mm graded stone aggregate reinforced with 8mm dia mild steel bar 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
S&F in repair 4 mm dia steel wire in and including suitable size GI pipe light grade, from earth electrode including connection with brass nut, bolt, spring washer, surface or in recess for connections etc as required complete all as specified and directed. Note :- Excavation and earthwork required for this items shall be measured and paid seperatly in respective items.
S&F in replacement of MCCB 63 Amps to 100 Amps,16 KA,3 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 63 Amps to 100 Amps,16 KA,4 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 200 Amps,25 KA,3 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 200 Amps,25 KA,4 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 250 Amps,25 KA,3 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 250 Amps,25 KA,4 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 400 Amps,36 KA,3 Pole,415V complete all as specified and directed.
S&F in replacement of MCCB 400 Amps,36 KA,4 Pole,415V complete all as specified and directed.
S&F in repair,Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole 32 Amps MCB TP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc the disturbed surfaces to match the existing complete all as specified and directed.
Note for ser item No. 1 to 232 :- 1. The contractor shall provide and deploy Skilled technician with helpers(as directed by GE / Engineer-in-charge) and contractor's site supevisor/site engineer shall report at 0900 hrs daily upto 1700 hrs excluding Sunday & holiday to collect the complaints / job card for attending emergent complaints of any capacity & type of Air Conditioning, water cooler, desert cooler, deep freezer, freeze ,ceiling fan/ exhaust fan/ geysers of any size including carrying out minor repairs as required to Make the system in order / functional including replacing minor part complete all as specified and directed by JE E/M / Engineer-in-charge. 2. The complaints shall be attended with in 48 hrs. If the complaints is/are not attended /not completed on the Stipulated time period (except repair/ replacement of major items, like replacement of cooling coil, condensing coil, fan motor etc in the openion of Engr -in- charge) recovery will be done as follows :- (a) After 48 Hrs, (Except Major repair in the openion of Engr-Charge) Rs - 1000.00 Per complaint per day till rectification of defects and in the meantime complaints will get rectified by the deptt by other means, the penalty of twice of rectification cost shall be made from contractor dues and the decision of GE in this regard shall be final & binding and no re presentation what so ever shall be entertained. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area and quoted rates are deemed to be included for this provision. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
S&F in repair Integral LED Street Light Luminaire 25 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories complete all as specified and directed.
S&F in repair Integral LED Street Light Luminaire 30 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories. complete all as specified and directed.
S&F in repair Integral LED Street Light Luminaire 36 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories complete all as specified and directed.
S&F in repair Integral LED Street Light Luminaire 60 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories complete all as specified and directed.
S&F in repair Integral LED Street Light Luminaire 70 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories complete all as specified and directed.
S&F in repair Integral LED Street Light Luminaire 90 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories complete all as specified and directed.
S&F in repair Integral LED Street Light Luminaire 120 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories complete all as specified and directed.
S&F in repair Integral LED Street Light Luminaire 150 W comprising of epoxy powder coated pressure die cast aluminium housing, including 40 mm dia, med grade or suitable for new fitting size GI Pipe 1.2 mtr long complete with accessories complete all as specified and directed.
S&F in repair LED flood lights fitting 40 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system.complete all as specified and directed.
S&F in repair LED flood lights fitting 60 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system complete all as specified and directed.
S&F in repair LED flood lights fitting 70 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system complete all as specified and directed.
S&F in repair LED flood lights fitting 100 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system complete all as specified and directed.
S&F in repair LED flood lights fitting 150 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system complete all as specified and directed.
S&F in repair LED flood lights fitting 200 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system complete all as specified and directed.
S&F in repair LED flood lights fitting 250 watts High power LED and unique flood optics to ensure uniform distribution and maintenance free system with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance system complete all as specified and directed.
S&F in repair driver suitable for LED street light/flood light fitting of 25 to 36 wattage complete all as specified and directed. Make:- Wipro CAT Part No LPV-35-12/24 and equivalent in Bajaj/ Havells/HPL as approved.
S&F in repair driver suitable for LED street light/flood light fitting of 50 to 60 wattage complete all as specified and directed. Make :- Wipro CAT Part No LPV-60-12/24 and equivalent in Bajaj/ Havells/HPL as approved.
S&F in repair driver suitable for LED street light/flood light fitting of 70 to 75 wattage complete all as specified and directed. Make :- Wipro CAT Part No ELG-75-24/48 and equivalent in Bajaj/ Havells/HPL as aprroved.
S&F in repair driver suitable for LED street light/flood light fitting of 90 to 100 wattage complete all as specified and directed. Make :- Wipro CAT Part No ELG-100-24/48 and equivalent in Bajaj/ Havells/HPL as aprroved.
S&F in repair driver suitable for LED street light/flood light fitting of 120 to 150 wattage complete all as specified and directed. Make :- Wipro CAT Part No ELG-150-24/48 and equivalent in Bajaj/ Havells/HPL as aprroved.
S&F in repair driver suitable for LED street light/flood light fitting of 200 wattage complete all as specified and directed. Make :- Wipro CAT Part No ELG-200-24/48 and equivalent in Bajaj/ Havells/Halonix/HPLas approved.
S&F in repair driver suitable for LED street light/flood light fitting of 250 wattage complete all as specified and directed. Make :- Wipro CAT Part No ELG-240-24/48 and equivalent in Bajaj/ Havells/Halonix/HPL as approved.
S&F in repalcement junction boxes out door type weather proof with fixing accessories made out of moulded PVC size 250x200x80 mm to be fixed at the height of 1 M from bottom of street light pole complete with wiring, arrangement for MS Clamp, cable entery/exit, 01 No. MCB SP 6 Amps, 4 pole connector for fixing cable etc complete all as specified and directed.
M&L for Hiring of Cable testing van (Fault Finder) for detecting the location of fault in the LT UG cable 1.1 KV and HT UG cable 11 KV grade of any size complete all as specified and directed.
M&L in replacement heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 70 to 150 Sqmm, single core, copper cable including all accessories required complete all as specified and directed.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 10 to 25 Sqmm four core copper cable including all accessories required complete all as specified and directed.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 6 to 10 Sqmm two core copper cable including all accessories required complete all as specified and directed.
M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 16 to 35 Sqmm 3.5/4 core including all accessories required complete all as specified and directed.
S&F in repair single core flexible copper conductor PVC insulated and cable 4 sq mm , 1100 volt, confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material complete all as specified and directed.
S&F in repair single core flexible copper conductor PVC insulated and cable 6 sq mm , 1100 volt confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material complete all as specified and directed.
S&F in repair single core flexible copper conductor PVC insulated and cable 10 sq mm , 1100 volt, confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material complete all as specified and directed.
S&F in repair on wall/ceiling/panel single core flexible copper conductor PVC insulated and cable 16 sq mm , 1100 volt, confirming to IS : 694 connecting to UPS/MCCB/DB and other equipment with lugs, glands and necessary jointing material complete all as specified and directed.
Supply only 11 KV grade EN- 13319-2000 Rubber insulating seamless rubber Hand safety gloves complete all as specified and directed. Make :- Cat Part No- JG of Jyot manufacturer or equivalent as approved.
Supply only 22 KV grade insulating seamless natural latex rubber Hand safety gloves Item complete all as specified and directed. Make :- Part No- 33kv jyot of Jyot manufacturer or equivalent make as approved.
S&F in replacement LED Fantasy Bollard LB14 of 11 Watt IP 65 protection,corrosion resistance better optics for uniform distribution complete all as specified and directed.
S&F in replacement LED post top lantern 35 to 45 watts complete all as specified and directed.
M&L in replacement Reinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 100 mm ,half round (02 Nos for top & bottom) complete all as specified and directed.
Taking down carefully from poles defective street light fitting 25/35/45/70/150/250/ 400W any type from pole/bldg for repairs and refixing the same after replacing defective accessories with new accessories of any type & including PVC insulated sheathed copper conductor connection of cable of existing size complete all as specified and directed.
M&L for Cutting of branches of tree of various length to keep a clear distance 2 mtr from the Street light pole and depositing the cut branches upto a distance of 50 mtr away from the LT/HT/ overhead line/ Transformer complete all as specified and directed. Note :- Each span between pole to pole shall be measured as one job
S&F in replacement Bracket Pole for Flood Light Fitting, round shape suitable for four to eight flood light fitting & mounted on any hight of pole or as per site requirement, made out of iron bar of suitable size as per existing shape complete all as specified and directed.
Supply and errecting in true vertical position steel tubular swaged pole, swan neck type, single arm, 9 Metre long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified, type 410 SP-31, including painting with anti corrosive black bituminous paint internally complete and externally up to planting depth with and externally exposed portion with Aluminium paint two coat over a coat of red oxide primer upto 1.5 mtr above ground level, including taking down unsv/ damaged pole all as required at site complete all as specified and directed. Note:- Excavation and earth work, PCC for foundation and coping shall be measured and paid seperately under respective items of this schedule.
Supply,laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 400 Sqmm 3.5 core complete all as specified and directed.
All as per item Ser No 274.00 above but 150 sq mm 3.5 core.
All as per item Ser No 274.00 above but 95 sq mm 3.5 core.
All as per item Ser No 274.00 above but 70 sq mm 3.5 core.
All as per item Ser No 274.00 above but 35 sq mm 3.5 core
All as per item Ser No 274.00 above but 25 sq mm 3.5 core.
All as per item Ser No 274.00 above but 10 sq mm 2 core.
All as per item Ser No 274.00 above but 6 sq mm 2 core.
M&L for plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations of poles complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping, bed block etc including necessary form work complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate etc as in foundaction including necessary form work complete all as specified and directed.
S&F in repair PVC insulated sheathed wire with copper conductor flexible 2 core 2.5 sqmm with one core 1.5 sq mm earth wire PVC insulated fixed to FRP junction box of street light fitting with suitable clamp as required for 8.5/9 Metre long pole for fixing to existing pole and conduit including suitable size of lugs for looping complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 m in depth for foundation and getting out in Soft /Loose Soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 m in depth for foundation and getting out in Hard/Dense soil complete all as specified and directed.
Returning filling in, incluiding spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 32x6 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia, light grade, GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 32mm x 6mm upto 7.5 Metre. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover, 50mm thick, 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
S&F in repair 25x4 mm galvanised iron strip earth continuity conductor on wall /floor and connected to equipment including nut & bolts of suitable size complete all as specified and directed.
S&F in replacement of MCCB 125 Amps,16 KA,3 Pole,415V complete all as specified and directed.
S&F in replacement MCB TP 63 Amps, 415 volts complete all as specified and directed
S&F in replacement MCB TP 40 Amps, 415 volts complete all as specified and directed
M&L in repair Mild steel plates, chequered 5 mm thick of grade Fe-410 W (Gde-E-250), quality B complete all as specified and directed.
M&L in replacement single pointed air termination aluminium rod, 12 mm dia, 300 mm long and tightening with screws complete all as specified and directed.
M&L in repair aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
M&L in replacement test point terminal block made of gun metal or phosphorus bronze size 75X75X25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and directed.
Design, supply,install, testing and comissioning of free standing floor mounted, dust and vermin proof Panel of suitable size for out door installation, factory made, both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted witrh epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 600 ,Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkable sleeves,with 600 mm depth of the panel. The panel shall be modular/cubical type with bus bar chamber cable alloy and provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc:-
INCOMING :- (a) MCCB 4 pole 400 Amps, rup capacity 36 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming OUTGOING :- (a) MCCB 4 pole 250 Amps, rup capacity 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release typewith rotary handle - 01 Nos Out going (b) MCCB 4 pole125 Amps, rup capacity 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 01 Nos Out going (c) MCCB 3 pole 63 Amps, rup capacity 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going (d) LT Danger notice plate -01 No (e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables
Attending day to day complaints of street light / flood light / bollard light/ tower lights of any make/type/ capacity and repairing for proper functioning including replacing small parts. Including carrying out minor repairs etc as required to make the system in order / functional including replacing fuse wire , copper cable , copper thimbles ,glands , earthing wire, cable jointing complete all as specified and directed. Note :- (i) Rate of Fuse wire, copper cable, copper thimbles, glands, earthing wire are deemed to be included in quoted rate of this item. (ii) Complaints shall be attended in Zone-B/KWC residential accn under GE(I) R&D Delhi AOR as directed by Engr in Charge and workmen shall be present daily round the clock for any emergent complaints assigned for complete period of contract complete all as specified and directed. (iii) Contractor will provide ladder for carrying out repair/attending complaints of street light / flood light etc at any height without any extra cost in this respect. (iv) Necessary insurance coverage shall be taken for their all staff by the bidder before commencement of the works and policy of the same shall be submitted to the Engr-in-Charge before comencement of item/work. (v) All rates for the above are deemed to be included in Sch 'A'(BOQ) items (vi) Attending five number of complaints by the workman shall be measured as one job.
M P TYAGI ENGINEERS AND CONTRACTORS
SNOWY ENGINEERING INC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .