GE SATWARI
GE SATWARI
REPAIR/MAINT OF LT PANELS,UPS STABILIZERS AND ALLIED WORKS UNDER AGE E/M OF GE SATWARI
2025_MES_693321_1
GEJM-78/2024-25
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SATWARI
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
GE SATWARI
₹70,000
Yes
7 Mar 2025
15 Jan 2025
14 Feb 2025
15 Jan 2025
12 Feb 2025
29 Jan 2025
Amount
Taking out broken hinges/unserviceable hinges & door handles from feeder pillar/LT Panel and replace the same with mild steel hinges cold rolled of same size through spot welding & Mild steel sliding door bolt of same size including making necessary adjustment for free and smooth movement of panel and spray painting two coats of powder coating inside & outside the panel complete all as specified and directed.
Taking out the damaged/deshaped part/portion of the LT Panel/feeder pillar and repalce the same with new portion made out of CRCA sheet 3mm thick including making necessary adjustment and allignment to make the existing feeder pillar/LT Panel to its required shape and size including spray painting two coats of powder coating inside & outside the panel complete all as specified and directed
Taking out the existing unserviceable voltmeter, ammeter, phase indication lamps, CTs of any description and size and S&F digital voltmeter, ammeter, phase indication lamps,CTs as per existing capacity and sizes complete all as specified and directed.
S&F in replacement MCCB 630 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 400 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 315 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 250 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 200 Amp, 4 pole,25 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 160 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 125 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 100 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 63 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 100 Amp, 3 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCCB 125 Amp, 3 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
S&F in replacement MCB DP, 40 Amps, 10 KA, C curve including making all connections with proper thimbling and connectors complete all as specified and directed.
S&F in replacement MCB DP, 32 Amps, 10 KA, C curve including making all connections with proper thimbling and connectors complete all as specified and directed.
S&F in replacement MCB SP, 6 to 32 Amps, 10 KA, C curve including making all connections with proper thimbling and connectors complete all as specified and directed.
S&F in replacement contactor MO C3 complete all as specified and directed.
S&F in replacement contactor MO C5 complete all as specified and directed.
S&F in replacement contactor MO C10 complete all as specified and directed.
S&F in replacement contactor MO C15 complete all as specified and directed.
S&F in replacement contactor MO C20 complete all as specified and directed.
S&F in replacement MCB TP, 6A, C curve in existing panels with proper thimbling complete all as specified and directed.
S&F in replacement MCB TP, 10A, C curve in existing panels with proper thimbling complete all as specified and directed.
S&F in replacement MCB TP, 20A, C curve in existing panels with proper thimbling complete all as specified and directed.
S&F in replacement MCB TP, 40A, C curve in existing panels with proper thimbling complete all as specified and directed.
S&F in replacement APP technology standard duty capacitor 1 Kvar in existing panels all as specified and directed.
S&F in replacement APP technology standard duty capacitor 2 Kvar in existing panels all as specified and directed.
S&F in replacement APP technology standard duty capacitor 5 Kvar in existing panels all as specified and directed.
S&F in replacement APP technology standard duty capacitor 10 Kvar in existing panels all as specified and directed.
S&F in replacement onload change over switch, 63 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
S&F in replacement onload change over switch, 100 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
S&F in replacement onload change over switch, 160 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
S&F in replacement onload change over switch, 200 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
S&F in replacement onload change over switch, 250 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
S&F in replacement Bus bar chamber, TPN including aluminium bus bar 200A, IP 42, front openable type including fixing arrangement on wall, inlcuding provision of thimble, nut bolts etc complete all as specified and directed.
Supply, installation, testing and commissioning of outdoor automatic power factor control panel, 40 KVAR, suitable for operation at 415V, 3 phase AC 50 Hz power supply, floor mounted, compartmentalised, load bearing structure of panel fabricated out of 3.15 mm CRCA sheet, partitions, doors etc made of 2mm thick sheet with KIOSK type body having openable front and back doors. The panel shall have angle iron mounting base frame of 600 mm height made out of 50x50x5 mm angle iron. General arrangement drawing shall be got approved before commencing manufacturing. The panel duly powder coated with RAL 7032 shade consisting of following components :- (A) Incomer: (i) MCCB 100A,3 pole ,25 KA having adjustable thermal release -01 No (ii) 3 phase LED indications with control MCBs of 6A SP-01 Set (iii) Aluminium Busbar 200A, TPN, EC grade mounted on DMC supports insulated with color coded heat shrinkable sleeves.-01 No (iv) 3 phase 10 KVAR capacitor can- type 440 volts-04 Nos (v) 3 phase 10 KVAR capacitor duty contactor with additional contact block -04 Nos (vi) MCB 32A, 3P,10 KA-04 Nos (vii) Automatic power factor controller 4 Step with control circuits for Auto/Manual operation of Individual bank, ON indication for each capacitor, control MCBs, copper wiring, power wiring for capacitor banks using suitable size copper wires.-01 No
Supply, installation, testing and commissioning of outdoor automatic power factor control panel, 50 KVAR, suitable for operation at 415V, 3 phase AC 50 Hz power supply, floor mounted, compartmentalised, load bearing structure of panel fabricated out of 3.15 mm CRCA sheet, partitions, doors etc made of 2mm thick sheet with KIOSK type body having openable front and back doors. The panel shall have angle iron mounting base frame of 600 mm height made out of 50x50x5 mm angle iron. General arrangement drawing shall be got approved before commencing manufacturing. The panel duly powder coated with RAL 7032 shade consisting of following components :- (A) Incomer: (i) MCCB 100A,3 pole ,25 KA having adjustable thermal release -01 No (ii) 3 phase LED indications with control MCBs of 6A SP-01 Set (iii) Aluminium Busbar 200A, TPN, EC grade mounted on DMC supports insulated with color coded heat shrinkable sleeves.-01 No (iv) 3 phase 10 KVAR capacitor can- type 440 volts-05 Nos (v) 3 phase 10 KVAR capacitor duty contactor with additional contact block -05 Nos (vi) MCB 32A, 3P,10 KA-05 Nos (vii) Automatic power factor controller 6 Step with control circuits for Auto/Manual operation of Individual bank, ON indication for each capacitor, control MCBs, copper wiring, power wiring for capacitor banks using suitable size copper wires.-01 No
Supply, installation, testing and commissioning of outdoor automatic power factor control panel, 75 KVAR, suitable for operation at 415V, 3 phase AC 50 Hz power supply, floor mounted, compartmentalised, load bearing structure of panel fabricated out of 3.15 mm CRCA sheet, partitions, doors etc made of 2mm thick sheet with KIOSK type body having openable front and back doors. The panel shall have angle iron mounting base frame of 600 mm height made out of 50x50x5 mm angle iron. General arrangement drawing shall be got approved before commencing manufacturing. The panel duly powder coated with RAL 7032 shade consisting of following components :- (A) Incomer: (i) MCCB 160A,3 pole ,25 KA having adjustable thermal release -01 No (ii) 3 phase LED indications with control MCBs of 6A SP-01 Set (iii) Aluminium Busbar 200A, TPN, EC grade mounted on DMC supports insulated with color coded heat shrinkable sleeves.-01 No (iv) 3 phase 10 KVAR capacitor can- type 440 volts-05 Nos (v) 3 phase 25 KVAR capacitor can- type 440 volts-01 No (vi) 3 phase 10 KVAR capacitor duty contactor with additional contact block -05 Nos (vii) 3 phase 25 KVAR capacitor duty contactor with additional contact block -01 No (viii) MCB 32A, 3P,10 KA-05 Nos (ix) MCB 63A, 3P,10 KA-01 No (x) Automatic power factor controller 6 Step with control circuits for Auto/Manual operation of Individual bank, ON indication for each capacitor, control MCBs, copper wiring, power wiring for capacitor banks using suitable size copper wires.-01 No
Disconnecting existing electrical connections,dismantling,opening, servicing, cleaning existing autmatic voltage stabilizer for automatic operation, oil cooled ,servo controlled type of capacity 100 KVA and refixing/re-installating the same complete all as specified and directed. Note : (i) Replacement of parts (if any) found damaged during repair shall be measured and paid separately.
Disconnecting existing electrical connections,dismantling,opening, servicing, cleaning existing autmatic voltage stabilizer for automatic operation, oil cooled ,servo controlled type of capacity 50 KVA and refixing/re-installating the same complete all as specified and directed. Note : (i) Replacement of parts (if any) found damaged during repair shall be measured and paid separately.
Disconnecting existing electrical connections,dismantling,opening, servicing, cleaning existing autmatic voltage stabilizer for automatic operation, oil cooled ,servo controlled type of capacity 20 to 40 KVA and refixing/re-installating the same complete all as specified and directed. Note : (i) Replacement of parts (if any) found damaged during repair shall be measured and paid separately.
S&F in replacement diameter coil with supper enameled copper wire for voltage stabilizer of capacity100 KVA complete all as specified and directed.
S&F in replacement diameter coil with supper enameled copper wire for voltage stabilizer of capacity 50 KVA complete all as specified and directed.
S&F in replacement diameter coil with supper enameled copper wire for voltage stabilizer of capacity 20 to 40 KVA complete all as specified and directed.
Dismantling and rewinding of dimmer coil with super enameled copper wire including varnishing tapping and insulating material of voltage stabilizer of capacity 100 KVA complete all as specified and directed.
Dismantling and rewinding of dimmer coil with super enameled copper wire including varnishing tapping and insulating material of voltage stabilizer of capacity 50 KVA complete all as specified and directed.
Dismantling and rewinding of dimmer coil with super enameled copper wire including varnishing tapping and insulating material of voltage stabilizer of capacity 20 to 40 KVA complete all as specified and directed.
M&L for dismantling of primary & secondary coils of capacity 100 KVA carefully, taking out winding wire, preparing for rewinding with super enameled copper winding wire of appropriates gauge with allied insulating material, varnishing the winding with air drying, insulating varnish, heat treatment complete all as specified and directed.
M&L for dismantling of primary & secondary coils of capacity 50 KVA carefully, taking out winding wire, preparing for rewinding with super enameled copper winding wire of appropriates gauge with allied insulating material, varnishing the winding with air drying, insulating varnish, heat treatment complete all as specified and directed.
M&L for dismantling of primary & secondary coils of capacity 30-45 KVA carefully, taking out winding wire, preparing for rewinding with super enameled copper winding wire of appropriates gauge with allied insulating material, varnishing the winding with air drying, insulating varnish, heat treatment complete all as specified and directed.
M&L for replacement of printed circuit board (PCB) complete all as specified and directed.
M&L for replacement of dimmer brush with carbon brush & brush holder complete all as specified and directed.
M&L for replacement of analog amp meter 96 sqmm, 0-200 amps with CTs complete all as specified and directed.
M&L Repalcement of internal wiring for DC supply with suitable size of LT panels complete as as specified and directed.
M&L for replacement of brass studs fixed for input & output of stabilizer of 100 KVA capacity with brass nuts complete all as specified and directed.
M&L for replacement of brass studs fixed for input & output of stabilizer of 50 KVA capacity with brass nuts complete all as specified and directed.
M&L for replacement of brass studs fixed for input & output of stabilizer of 20 KVA to 50 KVA capacity with brass nuts complete all as specified and directed.
S&F indicator lamp set (RYB) complete all as specified and directed
BMMJ TRADERS AND ENGINEERS (BID ID -3232471)
M/S ASHOK KUMAR SURI (BID ID -3232526)
Durga Electricals (BID ID -3229739)
M/S GULATI ENGINEERING WORKS (BID ID -3237270)
kailu construction co (BID ID -3232361)
AUTOMATION AND SWITCHGEAR PANELS (BID ID -3238208)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .