| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹28.3 L+₹80,830 (2.94%)Rejected-AOC | L2 | Rejected-AOC NOT ACCEPTED | |
| 3 | L3₹29.1 L+₹1.6 L (5.78%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED | |
| 4 | L4₹29.5 L+₹2.0 L (7.14%)Rejected-AOC RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-AOC NOT ACCEPTED | |
| 5 | L5₹29.7 L+₹2.2 L (7.95%)Rejected-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L5 | Rejected-AOC NOT ACCEPTED |
| Sl No | Description | Qty | Unit | GS TRADERS L5 | Vasavi Electricals L1 | MAJ CONSTRUCTIONS L3 | RAMSON TRADERS L10 | SREE VARU ELECTRICALS L2 | Gee Kay Projects L7 | NAVEEN ENTERPRIESES L6 | EX SOLDIERS MECHANICAL WORKS L4 | Varsha Enterprises L9 | Chandana Enterprises L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing taken down materials to a place where ordered for crediting including making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed.. | 1,510 | Per Point | 15 ₹22,650 | 10 ₹15,100 Lowest | 20 ₹30,200 | 20 ₹30,200 | 50 ₹75,500 | 36 ₹54,360 | 10 ₹15,100 Lowest | 15 ₹22,650 | 15 ₹22,650 | 15 ₹22,650 |
| 2.00 | Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic conduit (Medium Grade) surface in stone wall or any type of existing masonry conduite conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-(a) One light / Fan / bell point controlled by one 5 Amps switch one way | 840 | Per Point | 575 ₹4,83,000 | 550 ₹4,62,000 Lowest | 600 ₹5,04,000 | 1,200 ₹10,08,000 | 650 ₹5,46,000 | 630 ₹5,29,200 | 680 ₹5,71,200 | 600 ₹5,04,000 | 600 ₹5,04,000 | 750 ₹6,30,000 |
| 3.00 | (b) One 3 pin socket point 5 Amp on independent board | 300 | Per Point | 575 ₹1,72,500 | 550 ₹1,65,000 Lowest | 600 ₹1,80,000 | 1,200 ₹3,60,000 | 650 ₹1,95,000 | 630 ₹1,89,000 | 680 ₹2,04,000 | 600 ₹1,80,000 | 600 ₹1,80,000 | 750 ₹2,25,000 |
| 4.00 | (c) One 3 pin socket point 5 Amp on same board with other switches.(to be provide new point as ordered at site) | 200 | Per Point | 100 ₹20,000 | 100 ₹20,000 | 150 ₹30,000 | 150 ₹30,000 | 150 ₹30,000 | 90 ₹18,000 Lowest | 100 ₹20,000 | 150 ₹30,000 | 150 ₹30,000 | 120 ₹24,000 |
| 5.00 | (d) One light point contrlled by two, two way switchs , single pole | 20 | Per Point | 750 ₹15,000 | 650 ₹13,000 | 750 ₹15,000 | 1,300 ₹26,000 | 900 ₹18,000 | 810 ₹16,200 | 680 ₹13,600 | 620 ₹12,400 Lowest | 807 ₹16,140 | 780 ₹15,600 |
| 6.00 | All as per item No. 2 here-in-above but with 2.5sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed. | 150 | Per Point | 775 ₹1,16,250 | 800 ₹1,20,000 | 780 ₹1,17,000 | 1,300 ₹1,95,000 | 950 ₹1,42,500 | 900 ₹1,35,000 | 810 ₹1,21,500 | 720 ₹1,08,000 Lowest | 807 ₹1,21,050 | 850 ₹1,27,500 |
| 7.00 | Supply and fix Switch piano, flush button single pole, 5 Amps one way. | 790 | Each | 26 ₹20,540 | 28 ₹22,120 | 30 ₹23,700 | 40 ₹31,600 | 30 ₹23,700 | 27 ₹21,330 | 30 ₹23,700 | 20 ₹15,800 Lowest | 24 ₹18,960 | 33 ₹26,070 |
| 8.00 | Supply and fix Switch piano, flush button single pole, 5 Amps two way. | 40 | Each | 35 ₹1,400 | 40 ₹1,600 | 30 ₹1,200 Lowest | 60 ₹2,400 | 35 ₹1,400 | 45 ₹1,800 | 30 ₹1,200 Lowest | 50 ₹2,000 | 40 ₹1,600 | 39 ₹1,560 |
| 9.00 | Supply and fix Switch sokcet combination flush type 5 Amp , 2-in-1 muliti purpose | 500 | Each | 95 ₹47,500 | 125 ₹62,500 | 100 ₹50,000 | 110 ₹55,000 | 150 ₹75,000 | 117 ₹58,500 | 99 ₹49,500 | 99 ₹49,500 | 105 ₹52,500 | 90 ₹45,000 Lowest |
| 10.00 | Supply and fix Switch socket combination flush type 5/16 Amps , 5-in-1 universal multipurpose | 150 | Each | 160 ₹24,000 | 200 ₹30,000 | 145 ₹21,750 | 190 ₹28,500 | 175 ₹26,250 | 180 ₹27,000 | 170 ₹25,500 | 170 ₹25,500 | 168 ₹25,200 | 130 ₹19,500 Lowest |
Tender Value
₹38.1 L
EMD Value
₹76,300
Closing Date
5 Jul 2025, 6:00 pmClosed
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
SPECIAL REPAIRS REPLACEMENT OF OLD ALUMINIUM WIRING WITH COPPER WIRING AND ALLIED WORKS AT VARIOUS MD ACCN UNDER GE CENTRAL BANGALORE
2025_MES_713247_1
8505E
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹76,300
Yes
28 Aug 2025
9 Jun 2025
7 Jul 2025
9 Jun 2025
5 Jul 2025
23 Jun 2025
9 Jun 2025 - 21 Jun 2025
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing taken down materials to a place where ordered for crediting including making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed..
Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic conduit (Medium Grade) surface in stone wall or any type of existing masonry conduite conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :-(a) One light / Fan / bell point controlled by one 5 Amps switch one way
(b) One 3 pin socket point 5 Amp on independent board
(c) One 3 pin socket point 5 Amp on same board with other switches.(to be provide new point as ordered at site)
(d) One light point contrlled by two, two way switchs , single pole
All as per item No. 2 here-in-above but with 2.5sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way.
Supply and fix Switch piano, flush button single pole, 5 Amps two way.
Supply and fix Switch sokcet combination flush type 5 Amp , 2-in-1 muliti purpose
Supply and fix Switch socket combination flush type 5/16 Amps , 5-in-1 universal multipurpose
Supply and fix bell push, flush button single pole, 5 Amps one way.
Supply and fix bell ding dong , 230 V AC single pole,, 5 Amps one way.
Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC square blocks.
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan.
Taking down existing light fittings fixed in any description and S&F new 10 Watt , 6000K, 230 Volt, 2ft Batten surface and wall mounted LED batten with aluminium extruded channel powder coated with diffuser for glare free light & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips
Taking down existing light fittings fixed in any description and S&F new 20 Watt , 6000K, 230 Volt, 4ft Batten surface and wall mounted LED batten with aluminium extruded channel powder coated with diffuser for glare free light & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips
S&F bldg security light light fittings 1x 35 Watt Ac 230v out door type LED street light with high pressure die cast aluminium and heat ressistent complete with driver ,lamp bracket with impact and corrosion resistent including thermal managment in multiple optics complete , IP65/66 and wired with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size all as specified and directed. Make : Crompton Greaves/Bajaj/ Philips
S&F steet light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flat iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair Sheet metal enclosure (ISI marked) distribution board for 415 volts, TPN 04 way Vertical type, double door, triple pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
S&F Sheet metal enclosure (ISI marked) distribution board for 240 volts, 8 Way SPN vertical type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
S & F in repair MCB single pole 6 to 32 Amps 240 volts, 'C' curve 10 kA rupturing capacity providing in DB complete all as specified and directed by Engr-in-charge.
S & F in repair MCB single pole & neutral 40 Amps 240 volts, 'C' curve 10 kA rupturing capacity providing in DB complete all as specified.
S & F MCCB TP&N 63 to 100 Amps 415 volts, 'C' Series 16 kA rupturing capacity providing in DB complete all as specified.
Taking down old existing sub main wiring and provide new submain wiring with 2 runs of 6 Sqmm single core PVC insulated, unsheathed, multi stranded copper conductor and one single core 6 Sqmm PVC insulated , unsheathed , multi stranded copper cable as earthing lead as per IS : 694 / 1990 drawn through and including non-metallic PVC rigid conduit of size 20/ 25 mm dia concealed in walls etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 6 Sqmm cable , one run 6 Sqmm cable and one run of PVC shall be measured as one unit length) .
M&L for taking down and dismantling of ceiling fan 1200mm/1400mm sweep 230 Volt 50 C/S AC of any make or model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition with & including replacing the bearing with similar type of exisitng one, worn out screws of the cover, split pin, twin core flexible copper wire of size 23/0.0076, locking nuts & machine screws with spring washer for ceiling fan blades, oiling and greasing including rewinding of ceiling fan by removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding etc & finally painting the ceiling fan with one coat of spray painting with white DUCO Paint & lettering & Numbering the same as per existing ,reassembling , refixing the same in same or different location asordered & finally testing the fan , complete all as directed. Note : (i) Spare Parts/accessories found unserviceable including bearings , rewinding etc which are required to make the fan functional shall be providsed by the contractor without any extra cost to Govt as quoted rate is deemed to be inclusive for the same .(ii) Quoted rate is deemed to be inclusive of painting .
S&F in repair of sheet metal enclosure of size 2000 x 1500 x 400 mm grouted on wall/floor in PCC with nuts and bolts made out of 2.0 mm thick CRCA sheet, having 09 Nos chamber for housing of 09 energy meters and SPN MCB with Peeping glass fixed PVC frame and one MCB SPN with fixing rail and suitable busbar chamber for fixing 05 Nos aluminium strips 300 Amp capacity each making holes for fixing aluminium lugs, complete internal wiring with 6 sqmm multistranded copper cable FRLSH, epoxy based bakelite sheet of suitable size for fixing of energy meters & MCBs, including indl chamber locking system & testing on completion complete all as directed. (Note : The quoted rate includes the cost of 09 nos MCB SPN 32 Amp complete).
S&F in repair of sheet metal enclosure of size 1800 x 1200 x 300 mm grouted on wall/floor in PCC with nuts and bolts made out of 2.0 mm thick CRCA sheet, having 07 Nos chamber for housing of 07 energy meters and SPN MCB with Peeping glass fixed PVC frame and one MCB SPN with fixing rail and suitable busbar chamber for fixing 05 Nos aluminium strips 300 Amp capacity each making holes for fixing aluminium lugs, complete internal wiring with 6 sqmm multistranded copper cable FRLSH, epoxy based bakelite sheet of suitable size for fixing of energy meters & MCBs, including indl chamber locking system & testing on completion complete all as directed. (Note : The quoted rate includes the cost of 07 nos MCB SPN 32 Amp complete).
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed
SREE VARU ELECTRICALS (BID ID -3348007)
MAJ CONSTRUCTIONS (BID ID -3339516)
EX SOLDIERS MECHANICAL WORKS (BID ID -3339447)
GS TRADERS (BID ID -3334707)
NAVEEN ENTERPRIESES (BID ID -3339072)
Gee Kay Projects (BID ID -3339719)
Chandana Enterprises (BID ID -3344901)
Varsha Enterprises (BID ID -3348507)
RAMSON TRADERS (BID ID -3340120)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .