| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.1 LAccepted-AOC 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | 1 | Accepted-AOC The lowest tenderer | |
| 2 | 2₹23.3 L+₹18,295 (0.79%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | 2 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
25 Sept 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINT TO EXTERNAL WATER SUPPLY AND ALLIED WORKS AT RS COLABA AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2020_MES_373274_1
8403/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE(NW) Navy Nagar, Colaba
Class D and category a(ii)
7 documents required · 7 mandatory
₹500
GE (NW) Navy Nagar
₹80,000
27 Nov 2020
29 Aug 2020
26 Sept 2020
29 Aug 2020
25 Sept 2020
12 Sept 2020
29 Aug 2020 - 18 Sept 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/ loose soil all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified. Note : For item No 1.00 and 2.00 above rate deemed to be included for earth work and form work required as per site requirement & as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and debris out side MD land all as specified.
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement all as specified.
Removing excavated material exc 250m but n.exc 500m and depositing where directed all as specified.
M & L for CI specials confirming to IS - 1538, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 100/150/200/250/300 mm bore pipes (joints and joining material shall be measured and paid seperately)
M & L for run lead joint in repair with pig lead including pumping out / bail out water and necessary excavation and earth work in any type of soil,to repair the joints for following sizes of pipes :-
300 mm bore
200 mm bore
150 mm bore
100 mm bore
M & L for Cutting existing cast iron pipes and reducing for insertion of CI fittings to required length in position for following sizes :-
300 mm bore
150 mm bore
100 mm bore
S&F in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 1.6, confirming to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed of following size.
300 mm bore
250mm bore
200 mm bore
150 mm bore
100 mm bore
Construction of brick masonry valve chamber in repair of size 1.2 x 1.2 x 1.2m (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified.
Supply and fix in repairs cast iron pipes with spigot and socket centrifugally cast class `LA' in any length laid in trenches of following sizes. MAKE:-LAMCO INDUSTRIES LTD/ ELECTRO STEEL
300mm bore
200mm bore
150mm bore
100mm bore
80mm bore
Supply/ Fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the sme with new GI pipe in short piece of full length.
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and lay in repair 3 layer (inner antimicrobial, outer UV stabilized) ISI marked IS-15801, PPR pipes SDR 7.4 (PN 16) and PPR plain fittings in trenches/ walls/ ceilings or laying in floor complete of sizes outer dia as below :- Make : SFMC/ Prince/ KPT
50mm bore
90mm bore
110mm bore
Supply and fix in repair/ replacement of PPR gate valve 50mm in existing line in position, make out of brass screwed both ends for PPR pipe with union, ISI marked complete all as directed.
Taking down GI tubing fixed to wall at location cleaning and refixing the same with clamping on wall including necessary fitting in high rise building (G+14 stories) for the following :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :- Make : Guide/BIR/SIR/BR ( ISI marked )
25mm bore
40 mm bore
50 mm bore
80 mm bore
Taking out existing unserviceabe lid cover of PVC water storage tank and supply/Fixing FRP lid cover on existing PVC tank including complete accessories for closing and locking arrangement as per BMC Specification. Suitable for :
5000 trs PVC tank (Approx dia 60 cm)
3000 Ltrs Ltrs PVC tank (Approx dia 52 cm)
S&F in repair MS plate cover 5mm thick of valve chamber, over head tank, including necessary fabrication work with hinges, handle and applying two coats of synthetic enamel paint over one coat of metal primer complete all as specified.
Taking down corroded MS sections and S&F angle iron frame of size 50 x 50 x 6 mm of valve chamber, over head tank, UG sump including necessary fabrication work with two coats of synthetic enamel paint over a coat of metal primer complete all as specified
S&F PVC water storage Tank hoisting and fixing in position at any location removing existing distmantling RCC/PCC OHT and new foundation making as well as disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection complete all as specified and directed.
5000 Ltr capacity
3000 Ltr capacity
2000 Ltr capacity
1000 Ltr Capacity
ASHOK ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .