| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | ₹17.3 L Quoted ₹17.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹18.0 L+₹29,731 (1.68%)Rejected-Finance | ₹18.0 L+₹29,731 (1.68%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹18.1 L+₹37,851 (2.14%)Rejected-Finance 1A 52 NETAJI SUBHASH NAGAR E M BY PASS SOUTH 24 PARGANAS WEST BENGAL 700100 | KOLKATA | WEST BENGAL | 700100 | ₹18.1 L+₹37,851 (2.14%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹18.2 L+₹52,187 (2.95%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹18.2 L+₹52,187 (2.95%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹18.4 L+₹69,291 (3.91%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | ₹18.4 L+₹69,291 (3.91%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
16 Nov 2019, 6:00 pmClosed
GE (AF) Mohanbari
GE (AF) Mohnabari, Mohanbari-Post, Dibrugarh-Dist, Pin-786012
REPAIR AND MAINTENANCE TO SUMMER COOLING APPLIANCES, GEYSERS AND OTHER CONNECTED E/M WORKS AT AFS MOHANBARI UNDER GE (AF) MOHANBARI.
2019_MES_290785_1
NIT No . 8001/171/01/E8 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AFS Mohanbari
As per tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Mohanbari
₹36,000
Yes
7 Jan 2020
18 Oct 2019
18 Nov 2019
18 Oct 2019
16 Nov 2019
2 Nov 2019
Amount
Material and labour for taking down window type Air Conditioner of 1.0 TR/1.5 TR / 2.0 TR, cleaning completely the cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water and refixing at same location with complete testing all as directed.
Dismantling covers of out-door and in-door units of split type Air Conditioner of capacity 1.0TR/1.5TR/2.0TR, cleaning completely the condenser coil and cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water, re-fixing the covers in same position complete as directed.
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe excluding gas charging and transporting & carrying out T&P required at site for Window type AC of capacity up to 2.0 TR all as specified and directed.
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe excluding gas charging and transporting & carrying out T&P required at site for Split type AC of capacity upto 2.0 TR all as specified and directed.
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe excluding gas charging and transporting & carrying out T&P required at site for Refrigerator of capacity upto 340 Litres all as specified and directed.
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe excluding gas charging and transporting & carrying out T&P required at site for Water Cooler of Capacity 40 Litres to 150 Litres all as specified and directed.
Labour only for collecting the complaints of various wards/departments etc pertaining to Split/window type Acs of any capacity/make from concerned JE E/M of AGE E/M, attending these at site to asses the actual fault after opening of ACs and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE E/M all as directed. Note :- Spare parts shall be measured and paid separately under appropriate Items Nos. 7.01 to 7.20 here-in- after.
Supply only running capacitor of capacity 36 Mfd in plastic container complete all as directed.
Supply only running capacitor of capacity 4 Mfd in plastic container complete all as directed.
Supply only Capillary Tube (Copper) of size same as existing complete all as directed.
Supply only Filter Strainer complete all as directed.
Supply only starting relay for 1.00/1.5/2.00 TR compressor all as directed.
Supply only Air filter made out Plastic frame and Nylon net suitable for any capacity split AC of any Make and model all as directed.
Supply only Thermostat Switch complete all as directed.
Supply only Contactor Relay suitable for any capacity split AC of any Make and model all as directed.
Supply only running capacitor of capacity 50 Mfd + 6 Mfd in plastic container complete all as directed.
Supply only running capacitor of capacity 45 Mfd + 6 Mfd in plastic container complete all as directed.
Supply only Blower Motor for Window type AC upto 2 Ton Capacity complete all as directed.
Supply only Blower Motor for Split type AC upto 2 Ton Capacity complete all as directed.
Supply only front grill for window type AC of 1.0/1.5/ 2.0 TR complete all as directed.
Supply only PCB Board for Split type AC complete all as directed.
Supply only Rubber bushing for blower motor for Window/Split type AC of any capacity complete all as directed.
Supply only Swing motor for split type AC of capacity 1.0 TR/1.5TR/2.0TR complete all as directed.
Supply only Display assembly for spilit type AC of any capacity complete all as directed.
Supply only Starting capacitor of capacity 100/120 mfd in plastic/metal container complete all as specified and directed.
Supply only Sensor for Indoor unit of Window/Split type AC any capacity complete all as directed.
Supply and fixing in repair 2.5 mfd capacitor for indoor split unit complete all as specified as directed.
Supply and fixing in repair Sealed unit compressor rotary type for Window/Split type AC of 1.5 Ton capacity complete all as directed.
Supply and fixing in repair Sealed unit Compressor reciprocating type for Window/Split type AC of 1.5 Ton capacity complete all as directed.
Supply and fixing in repair Sealed unit Compressor reciprocating type for Window/Split type AC of 2 Ton capacity complete all as directed.
Supply and fixing in repair Sealed unit Compressor rotary type for Window/Split type AC of 2 Ton capacity complete all as directed.
Supply and fixing in repair Refrigerator compressor for Refrigerator of capacity upto 260 Ltrs complete all as directed.
Supply and fixing in repair Water cooler compressor for Water Cooler of capacity above 40 litres and up to 150 ltrs complete all as directed.
Supply and fixing in repair Refrigerator compressor for Refrigerator of capacity above 260 litres and upto 440 Ltrs complete all as directed.
S & F in repairs, Metal plug top 20 Amps, 3 pin for split type ACs/ Window AC complete all as specified and as directed
S & F in repairs, Metal socket plug 20 Amps, 3 pin for split type ACs/ Window AC complete all as specified and as directed
S & F in repairs, MCB single pole 20 to 32 Amp complete all as specified and directed
Supply and fixed in repairs of PVC blower/fan blade with for Split ACs upto 2 ton complete as required at site complete all as directed.
Supply and fixed in repairs of aluminium blower / fan blade with alminium alloy bush, screw for window ACs upto 2 ton complete as required at site complete all as directed.
Supply and fixing in repair flexible drain pipe including provision of necessary accessories for fixing of drain pipe and testing complete for proper functioning for split type AC all as specified and directed.
Labour only for collecting the complaints of various wards/departments etc pertaining to Refrigerators/deep freezer of any capacity/make from concern JE E/M of AGE E/M, attendending these at site to asses the actual fault after opening of refrigerator and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE E/M all as directed. Note :- Spare parts shall be measured and paid separately under appropriate Item Nos. 22.01 to 22.14 here after.
Supply only Condenser coil.
Supply only Pin/Thread type lamp holder.
Supply only Bulb 15 watt (Pin/Thread type).
Supply only Ice tray.
Supply only Open type relay with overload protector.
Supply only Thermostat auto defrost.
Supply only Capillary tube (copper) as per existing.
Supply only Chill tray.
Supply only Ice Chamber for Refrigerator of capacity up to 340 Ltr.
Supply only Vegetable box.
Supply only Bimetal Relay.
Supply only Heating Element.
Supply only Frost free fan motor.
Supply only Timer.
Labour only for collecting the complaints of various wards/departments etc pertaining to Water Coolers of any capacity/make from concern JE E/M of AGE E/M, attendending these at site to asses the actual fault after opening of water coolers and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE E/M all as directed. Note :- Spare parts shall be measured and paid separately under appropriate Item Nos. 23.01 to 23.11 here after.
Supply only Push type tap copper alloy chromium plated 15 mm bore.
Supply only Rubber lining for top cover gasket (3 metre approx each cooler).
Supply only Starting relay suitable for 5/8 HP motor. Make :- SHRIRAM or equivalent.
Supply only Starting capacitor 80/100 mfd. Make :- Universal/ SARADA or equivalent.
Supply only Thermostat. Make :- Indofons/shriram/or equivalent.
Supply only Float valve Brass with fly nut screwed as per existing.
Supply only Over load protector. Make :- SHRIRAM or equivalent
Supply only Capilary tube as per existing size (Copper).
Supply only Blower motor as per existing.
Supply only CP Basin tray.
Supply only Running capacitor 15 mfd.
Supply and charging refrigeration gas R-22 for Split/window AC all as specified and directed. Make :- Mafron or euivalent.
Supply and Charging R-410 gas for Split/Window AC all as directed.
Supply and Charging R-134 gas for Refrigerator/water cooler/ Defreezer all as directed.
Dismantling, shifting and refixing of split type AC of capacity 1.5 to 2.0 TR including proper arrangement to keep outer unit (Angle iron with nut bolt) and gas charging as required type of refrigerant in the unit complete all as specified and directed.
Supply and fixing in repair sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt complete all as specified and directed.
Taking down out door unit of Split type AC 1.5TR/2.0 TR capacity removing unserviceable AC stand/angle iron bracket fixing new AC stand/angle iron bracket in repair (including two coats of paint over a red oxide primer) fixing to the wall by foundation bolts refixing the out door unit connecting the suction and discharge line complete inluding testing for efficient running complete all as directed.
Taking out Voltage Stablizer of capacity upto 2 KVA, transporting it to workshop, dismantling transformer unit, auto transformer barrier, electric circuit board etc with all cable connections carrying out repair/replacement of push on switch, transistor, capacitor, relay transistor, diode, condensor, voltmeter, PVC connector, indicator lamp, cut out, MCB etc , testing and commisioning to make it fully functionable complete all as directed.
Taking out Voltage Stablizer of capacity upto 3 KVA to 5 KVA, transporting it to workshop, dismantling transformer unit, auto transformer barrier, electric circuit board etc with all cable connections carrying out repair/replacement of push on switch, transistor, capacitor, relay transistor, diode, condensor, voltmeter, PVC connector, indicator lamp, cut out, MCB etc , testing and commisioning to make it fully functionable complete all as directed.
Taking down geyser of 50/35/25 ltrs capacity from its position after disconnecting water connections, opening of geyser to take out inner tank, examining the points of leakage and soldering the points to stop leakage, scraping and brushing down old paint with emery paper, applying two coats of white paint using spray machine spray painting and writing of MES No by black paint, complete all as specified and as directed.
Taking down geyser of 25 ltrs to 35 ltrs capacity from its position after disconnecting of existing water connection for taking out the unserviceable inner tank by opening the geyser and Supply & fixing in repair new inner tank and refixing in position after assembling and testing, complete all as specified and as directed.
Taking down geyser of 50 ltrs capacity from its position after disconnecting of existing water connection for taking out the unserviceable inner tank by opening the geyser and Supply & fixing in repair new inner tank and refixing in position after assembling and testing, complete all as specified and as directed.
Dismantling of existing unserviceable apparatus plate from Geyser of 50 litres capacity and Supply and fixing in repair new copper apparatus plate of same thickness so as to match the existing one with rubber gasket complete all as specified and as directed.
Dismantling of existing unserviceable apparatus plate from Geyser of 25/35 litres capacity and Supply and fixing in repair new copper apparatus plate of same thickness so as to match the existing one with rubber gasket complete all as specified and as directed.
Supply and fixing in repair glass wool suitable for geyser of any capacity complete all as specified and as directed.
Dismantling of existing unserviceable heating element from geyser and Supply and fixing in repair new heating element of 1.5 kw 230 volt, testing for its functionality and refixing all electrical and water connections complete all as specified and directed.
Dismantling of existing unserviceable heating element from geyser and Supply and fixing in repair new heating element of 2.0 kw 230 volt, testing for its functionality and refixing all electrical and water connections complete all as specified and directed.
Dismantling of existing old unserviceable thermostat of Geyser of any capacity and Supply and fixing in repair new thermostat with specifications to match with the existing one, including refixing all connections, testing for functionality etc. complete all as specified and as directed.
Dismantling of existing unserviceable plug top and Supply anf fixing in repair 15 Amp plug top with all connections and acessories complete all as specified and as directed.
Supply and fixing in repair PVC Connection pipe 15 mm dia 60 cm long heavy duty with two Nos brass chromium plated union complete all as specified and directed.
Material and labour for painting of Refrigerator/Water cooler with two coats of DUCO paint (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed.
Material and labour for painting of Window/split AC with two coats of DUCO paint (ISI grade) white using spray machine spray painting including cleaning, washing, preparation of old painted surfaces complete all as directed.
Taking down unserviceable stop valve and supply and fixing new stop valve CP of 15 mm bore complete all as directed.
Taking down indicator lamp of Geyser of any capacity and supply and fixing new indicator lamp of red, green colour complete all as directed.
Taking down old rusted clamps, nuts, bolts, washers etc in complete set and supply and fixing new clamp, nut, bolt, washer in complete set for hanging gyser all as directed.
Dismantling and taking out carefully unserviceable indoor electronic type PCB (Printed circuit Board) of split type AC 1.5 to 2 ton and repairing the wirh replacement parts/spare and refixing to existing position and including testing complete all as specified and directed.
Supply and fixing in repair outdoor fins type aluminium/ copper condensor of capacity 2.0 Ton split AC of outdoor complete all as specified and directed.
Material and labour for dismantling deep freezer checking out the fault of complete system for repair and servicing of Deep Freezer including replacement of spares as required and complete testing of deep freezer for full functionality complete all as specified and directed.
Supply and fixing sealed compressor for deep freezer up to 500 ltrs capacity including taking down old unserviceable compressor complete all as specified and directed.
Repairing body and base of Water Cooler of any capacity by cutting and removing defective body and base including providing body and base made up of plain MS Sheet of same thickness, necessary welding, brazing, soldering, carrying out leak testing and repair of leakage if any by arc (gas) welding complete all as specified and directed.
Material and labour for cutting holes in brick wall for fixing of window type Air Conditioner including removal of rubbish from the site of work outside MD land at any distance including necessary wooden frame work not less than 2" X 2" thick and size as per AC model including fair finish of side walls in cement mortar 1:6 and applying white wash/distemper etc to make it as before complete all as directed.
Supply and fixing in repair Service line charging valve 5/8'' (Brass) for Window/Split type AC any capacity including connection and testing complete all as directed.
Supply and fixing in repair Liquid line valve 1/4'' (Brass) for Window/Split type AC any capacity including connection and testing complete all as directed.
Supply and fixing in repair copper tube 5/8'' for Window/Split type AC any capacity including connection and testing complete all as directed.
Supply and fixing in repair copper tube 1/4'' for Window/Split type AC any capacity including connection and testing complete all as directed.
Supply and fixing in repair copper tube 1/2'' for Window/Split type AC any capacity including connection and testing complete all as directed.
Supply and fixing in repair copper tube insulation 1/4'' for Window/Split type AC any capacity including connection and testing complete all as directed.
Supply and fixing in repair copper tube insulation 1/2'' for Window/Split type AC any capacity including connection and testing complete all as directed.
S & F( in repairs) FR PVC insulated three core stranded copper cable of size 2.5 sqmm all as specified and directed .
Material and labour for rewinding of 01 KVA isolation transformer for voltage stabilizer with heavy duty super enamelled copper winding wire of existing guage including all insulation materials, varnishing, heating, etc cutting and removing the old burnt winding with replacement of defective parts required to constant voltage complete all as specified and directed
Supply and fixing in repair Brass CP plate pipe with adaptor 1/4" * 24" including connection , testing complete all specified and directed.
Taking out defective blower motor from Window type AC of capacity 1.0/1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
Taking out defective blower motor from Split type AC of capacity 1.0/1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
Taking out defective blower motor from Water Cooler of capacity upto 150 Litres and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
Kaushik Enterprises
M/s. R. K. Trading Company
STANDARD ELECTRIC WINDERS
Bimal Trading Company
M/S RK Trading
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .