Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.4 LAccepted-Finance PULWAMA JAMMU KASHMIR 192301 INDIA UDYAM JK 15 0009614 | PULWAMA | JAMMU AND KASHMIR | 192301 | 1 | Accepted-Finance The bidder has fulfilled the prerequisite formalities and stands qualified | |
| 2 | 2₹11.8 L+₹39,363 (3.44%)Accepted-Finance | 2 | Accepted-Finance The bidder has fulfilled the prerequisite formalities and stands qualified |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
12 Aug 2022, 4:00 pmClosed
Executive Engineer PHE Mech. Div. South Awantipora
Executive Engineer PHE Mech. Div. South Awantipora
Development of Separate Pump Station for Takibal Village at PHE Mechanical Karikadal
2022_PHE_181536_1
Awantipora 34
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
20 days
Awantipora
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer PHE Mech. Div. South Awantipora
₹24,000
Yes
27 Aug 2022
29 Jul 2022
13 Aug 2022
29 Jul 2022
12 Aug 2022
29 Jul 2022
Amount
Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 for with following specification are as under : PUMP : Discharge Range = 10000 GPH Head Range = 100 mtrs Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump = Submersible Pump Type of fluid to be handled= Clear Water MOTOR:- Motor Rating= 30.00 HP/As per OEM Method of starting = Star – Delta Speed = 3000 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 phase Efficiency = Not less than 90% Class of insulation = F/Suitable for above parameters
Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Size: DN80 PN:1.6/16
Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve( NRV) as per IS 5312. Size: 80 mm PN: 1.6/16
Fabrication ,Providing and fitting of 90-120 degree bend/elbow to be fabricated out of G.I pipe, 1 m length and flanged on both ends a to make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 80
Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 80 mm
Supply, Installation and testing of manual type triple gear chain pulley block along with mnrail geared travelling trolley y of proper specifications Capacity = 2 ton
Fabrication Providing and fitting of modular control panel of appropriate size fabricated out of 14SWG sheet having required openings/vents and protection class: IP-55 and fitted with accessories: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER with current density of suitable rating for 100/200 Ampere. All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards. b) Main Circuit Breaker (Incomer MCCB): as annexure A
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 Size: 25 sq.mm
Providing and fitting of 50 mm square single core copper cable for interconnecting various electrical gadets as per IS 694: 2010 along with thimbling as per requirement.
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9
Providing and installation of Junction Box with DP 32Amp MCB to serve as amin switch for LED lighting.
Providing, Installation and testing of 2KVA fully automatic voltage stabilizer
TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Providing of tool kit consists of following items As par Annexure A
Providing of good quality convenience and utility items as per following a) Providing of good quality bedding for night stay/Shift consisting of: - As par Annexure A
Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each)
Providing of 1 KW heat convector for operators for winter season.
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing the name of water supply scheme. 7x3 feet The Details will be provided by site incharge at the time of execution of Work
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site size= 20x3 feet The Details / Technical Specifications will be provided by site incharge at the time of execution of Work
Providing, fitting, testing and commissioning of Manually operated copper wound, 3-phase, AC power supply multi step voltage stabilizer. Rating: 50 KVA
Fabrication of 7’ (L) x 6’ (B) x 1.5' (H) angle iron bed for operators with back-height of 2 feet. The detailed drawing will be provided by site in charge.
Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 3 nos.
Providing and fitting of 200A, 415+_10%V, 50 Hz, 04 Pole, Handle Operated Changeover Switch in separate SS Enclosure.
Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as line from the DG Set to control i) 50 sqmm , 3.5core, LT cable
ii) 10sqmm, 2 core, LT cable
Electrification of Pump House, Premises and Operators Quarter as : Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. As par Annexure A
M/S SHALIMAR ENGINEERING WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .