Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹45.2 L+₹44,668.82 (1.00%)Rejected-Finance | L2 | Rejected-Finance Second lowest bidder | |
| 3 | L3₹50.5 L+₹5.7 L (12.7%)Rejected-Finance | L3 | Rejected-Finance Third lowest bidder |
Tender Value
₹47.2 L
EMD Value
₹96,000
Closing Date
4 Dec 2021, 6:00 pmClosed
GE Saugor
GE Saugor
PROVN OF MT GARAGE INCLUDING SPECIAL REPAIRS TO CERTAIN BLDGS AND OTHER LOW BUDGET WORKS UNDER GE SAUGOR
2021_MES_484466_1
GE/SGR/TOK-50 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Saugor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Saugor
₹96,000
Yes
3 Jan 2022
4 Nov 2021
6 Dec 2021
4 Nov 2021
4 Dec 2021
23 Nov 2021
Amount
Excavating over areas, not exc 1.5m deep and getting out in soft/loose soil including dressing/trimming sides and levelling/grading and ramming of bottoms of excavation, complete all as specified and directed
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation and getting out in hard/dense soil,including dressing/trimming sides and levelling/grading and ramming of bottoms of excavation complete all as specified and directed
Removing excavated materials (soil) to a distance not exc. 150 m and deposting where directed at a level not exc. 1.5m above the starting point complete all as specified and directed
M&L for moorum/red bajri filling in floors or pavings, laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
Returning filling in incl spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete complete all as specified and directed
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregates) in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc basement slabs, under reamed plies and mass concrete complete all as specified and directed
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregates) in Columns, pillars, piers, posts and struts and the like complete all as specified and directed.
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and directed.
M&L for RCC (Design Mix) M-25 (using 20mm graded stone aggregates) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and the like complete all as specified and directed.
M&L for form work to sides of concrete foundation , footings .base of columns, sides and soffits of plinth beams and similar works as in rough finshed flat surface complete all as specified and directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular rough finished surface complete all as specified and directed..
M&L for form work for rough finished surface to soffits of suspended slabs such as floor,roof slabs and landing not exceedind 200mm thick complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams,lintels,shelves and similar works as in rough finshed flat surface complete all as specified and directed.
M&L for form work to edges of concrete flats fair finished, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 10 cm wide complete all as specified and directed..
M&L for MS TMT bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed..
M&L for MS TMT bars 5mm dia and over upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed.
M&L for brick work with subclass‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks complete all as specified
M&L for rendering 15 mm thick on fair faces of brick work built in CM (1:4) finished the surface fair and even complete all as specified and directed.
M&L for 15mm thick rendering on cement mortar 1:6 on other than fair faces of brick work finished even & smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for rendering 10 mm thickcement plaster in CM 1:3 on concrete surfaces as in ceiling finish even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new cement plaster surfaces and applying two coats of oil bond distemper over a coat of primer all as specified & directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed..
M&L for preparing newly plastered wall surfaces and applying two coats of cement base paint on wall surfaces over one coat of primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed..
M&L for hard core of gauge not exc 63mm, deposited, spread and levelled in layers nexc 15 cm thick, watered and rammed to a true surface complete all as specified and directed..
M&L for 75 mm thick plain cement concrete type C-1, 1:3:6, (using 40mm graded stone aggregate) as in plinth protection, sub basse etc finishing the top surfaces even and smooth without using extra cement complete all as specified and directed..
M&L for 100mm thick plain cement concrete type C-1, 1:3:6, (using 40mm graded stone aggregate) as in hard standing complete all as specified and directed..
M&L for 75mm thick PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base floorings complete all as specified and directed..
M&L for 100mm thick PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base floorings complete all as specified and directed..
M&L for 25 mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in floorings, as in sub base of floor tiles in ground floor complete all as specified and directed..
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade laid over and including 15mm thick sceed bed in CM 1:6 complete all as specified and directed
All as per Srl item No. 33 above but in dado / skirting laid over and including 10mm thick rendering in CM (1:4).
M&L for 450mm x 350mm x 6 to7 mm thick glazed coloured ceramic tiles on vertical surface such as skirting, dado, etc..,of wall set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade laid over and including rendering 10mm thick in CM 1:4 complete all as specified and directed .
M&L for cement concrete 1:2:4, type B-1(using 20mm graded stone aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed..
S&F solid PVC door frame of size 50mmx47mm made out of 5mm thick wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube complete all as specified and directed..
S&F factory made solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face,incl 03 Nos of 100mm size stainless steel butt hinges for each shutter complete all as specified and directed..
M&L for second class hardwood plain, solid stright chowkats and frames, wrought, framed rebated on the solid, rounder or chamfered, put together with glue pinned at joints complete all as specified and directed..
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed..
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed..
S&F steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel complete all as specified and directed..
S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed..
S&F 100mm size stainless steel butt hinges, medium weight, cold rolled complete with stainless steel screw complete all as specified and directed..
S&F 150mm long aluminium anodized, barrel tower bolts extruded section complete all as specified and directed..
S&F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed..
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised. handle fabricated type complete all as specified and directed..
S&F vitreous China urinal, Half stall type, white complete including cp waste coupling and providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed..
S&F vitreous China wash hand basin white flat back of size 550mmx400 mm including cutting for and pinning in end of brackets,32 mm waste fittings,brass chromium plated for glazed ware sinks,basins etc.with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed.and flush pipe of polytethylene of low or high density or PVC 32 mm dia including waste pipe complete all as specified and directed..
S&F vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts flushing cistern and flush pipe) including plastic seat cover white and mild steel chromium plated aluminum hinging devices, connected to drains outlet complete all as specified and directed
S&F 10 litres capacity PVC, syphonic action type, flushing cistern low level, white with inlet ball valve float chain and pull and brackets and 32mm dia pvc flush pipe complete all as specified and directed..
S&F sinks made of stainless steel 1mm thick kitchen or labortory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified & directed.
S&F 15 mm dia bib taps, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed..
S&F 15mm bore angle stop valves, fancy type chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions & fixed complete all as specified and directed...
S&F 15 mm bore pillar tap, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or ' Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and directed..
S&F PVC connection of 15 mm dia with PTMT nuts of length 450 mm complete all as specified and directed.
S&F 20 mm bore galvanised steel tubes medium grade with all fittings for water supply pipes fixed to walls complete all as specified and directed...
S&F 15 mm bore Galvanized Steel tubes, medium grade with all fittings for water supply pipes fixed to walls complete all as specified and directed..
S & F PVC water storage tanks of 1000 ltrs capacity rotational moulded three layered wall construction (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed..
S&F ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of 20mm dia complete all as specified and directed..
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and forming benching as required, Internal dia of pipe 150mm complete all as specified and directed..
S&F PVC (SWR) pipes 110mm dia single sockted in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed..
S&F PVC (SWR) pipes 110mm dia single sockted in any length with rubber ring joints fixed to walls complete all as specified and directed...
S&F PVC (SWR) pipes 75mm dia single sockted in any length with rubber ring joints fixed to walls complete all as specified and directed...
S&F PVC (SWR) pipes 75mm dia single sockted in any length with rubber ring joints f laid in trenches or in floors complete all as specified and directed..
S&F PVC (SWR) junction single, (single T) equal or unequal with access door 110mm dia complete all as specified and directed..
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed..
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed..
S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed...
S&F PVC (SWR) bends any radius with access door, 75mm dia complete all as specified and directed..
M&L for concrete bed in 1:3:6, type C1 (using 20mm graded stone aggregates) to 100mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed..
S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe complete all as specified and directed..
Dismantling in laid dry or laid dry pointed stone slabs and tiles of any description or thickness in floors, aprons etc., complete all as specified and directed
Taking down timber roof trusses, coupled rafters or trussed beams of span exc 4m not exc 8m complete all as specified and directed
Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and directed.
S&F GI ( cold rolled) snap grid size of 600mm x 600 mm frame work of 24 x 38 x 0.60 mm, Tee Section ( bottom pre coated ) and 24 x 24 x 0.5 mm thick angle rung along the wall incl GI suspenders wire as per manufacturer instructions as in ceiling with and including S&F white Non Asbestos designer ceiling cement boards 4 mm thick including dismantling of wall ceiling board (fibre,pulp,insulation etc)or insulation board/ slab/ blankers, any thickness, including cover fillets complete all as specified and directed.
Taking down cement plaster on brick wall including raking out,joints hacking for key's scrubbing down with water complete all as specified and directed
M&L for raking out joints/ pointing to brick work in walls built in cement mortar complete all as specified and directed
M&L for machine pressed precast concrete interlocking paver block glossy finished, chemically treated any shape and size confirming to IS-15658-2006 size of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 30mm to 50mm thick stone dust cushioning complete all as specified and directed
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregates) as in, coping, benching and other similar work with weathering slightly rounded edges and throating etc as required with and incl all necessary form work complete all as specified and directed
M&L for two coat cement plaster, first coat 15mm thick CM 1:4 on brick wall surfaces and second coat cement plaster 5mm thick in CM 1:4 mixed with WPC finished even and smooth without using extra cement complete all as specified and directed. (Note:-WPC shall be measured & paid seperately under respective item).
Taking down chowkats/frames of area not exc 1.5 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed
Taking down chowkats/frames of area exc 1.5 Sqm and not exc 4.0 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed
M&L for pressed steel frames for doors 125mmx60mm with one or more rebates incl necessary fixing lugs, hinges, lock strike plate complete and back side of pressed steel frames filled with PCC 1:3:6 type C0 complete all as specified and directed
S&F 35mm thick second class hardwood, factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per : IS 1003 (part I), kiln seasoned and chemically pressure treated complete all as specified and directed
S&F 35mm thick glazed and skeleton shutters, factory made open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) and fitted to chowkats complete all as specified and directed
S&F aluminium windows sliding type three track powder coated consisting of frame bottom with gutter of size min 92.34 X 39 mm,sideand top of size min 92.34X29.70, shutters vertical 39X20 mm,shutter top &bottom of size min 20X39 mm ,shutter interlock min size 39X20 mm with rollers and conceled locking arrangements with 4 mm thick tinted glass with rubber gasket,brush and aluminium beading , ,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.45 mm dia etc including necessary cutting holes on wall and floor and confirming to IS complete all as specified and directed (Al. section thickness 1.50 mm }
S&F galvanised mild steel wire cloth, 0.46 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200 mm complete all as specified and directed.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300 mm complete all as specified and directed.
S&F mild steel pressed handles, oval type, stove enamelled black, Size of handle 125mm complete all as specified and directed.
S&F steel work in tubular trusses/purlins/rafters/posts with round/rectangula/square hollow mild steel section including angle cleats for jointing with welding complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, trapozoidal pattern of any colour having tensile strength of 550 Mpa as in roof covering/cladding in wall, fixed with self tapping screws, any gauge, thickness complete all as specified and directed.
S&F 0.45 mm thick galvalume sheet precoated coloured ridge suitable for profile pattern sheet fixed with self driving screws including dismantling existing damaged AC sheet ridge/hip for corrugated or semi corrugated sheets from roof , any gauge, thickness complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, trapozoidal pattern of any colour having tensile strength of 550 Mpa as in roof covering/cladding in wall, fixed with self tapping screws including dismantling plain or corrugated asbestos sheeting , any gauge, thickness complete all as specified and directed.
S&F 0.45 mm thick galvalume sheet precoated coloured ridge suitable for profile pattern sheet fixed with self driving screws including dismantling existing damaged AC sheet ridge/hip for corrugated or semi corrugated sheets from roof including dismantling plain or corrugated asbestos sheeting , any gauge, thickness complete all as specified and directed.
S&F mild steel plates (Plain or chequred) channels, square cut or notched forming holes, with riveted, bolted, welded attachement conforming to Fe 410 - W (Gde-E-250) quality-B complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat of red oxide primer including preparation new untreated steel of surface of any description not exc 10 cm in width or girth for wind ties complete all as specifed and directed.
M&L for preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for applying two coats of synthetic emulsion distemper, white or tinted over a coat of wall primer over & including Birla / J. K. wall care white putty 2mm thick for levelling new wall surface including preparation of surfaces complete all as specified and directed..
M&L for complete removal of existing treatment and applying Birla / J. K. wall care white putty 2mm thick for levelling the surfaces including properly making of "V' shaped crakes and filling of all crakes with crakes seal of walls and applying two coat of synthetic emulsion distemper over a coat of wall primer incl. preparation of surfaces of walls complete all as specified and directed.
M&L for applying two coats of exterior weather coat over one coat of exterior primer including preparation of surfaces of new walls complete all as specified and directed.. Make Asian ACE or equivalent
S&F mild steel work like flat iron including all necessary drilling,screwing, bolting , reveting & welding, etc and similar work conforming to Fe-290 Gde E-165 for wind ties,gutter strap and frame for cladding complete all as specified and directed.
S&F MS screw bolts machine made with hexagonal or square heads at one end and screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank 16 to 20mm and length exc 22.5cm and not exc 30cm complete all as specified and directed.
Excavation in post holes (or similar holes ) each not exc. 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cum, watering and removing, surplus soil to distance not exc, 50 mtr and making good surfaces in soft/loose soil complete all as specified and directed
M&L for PCC type B2, (1:2:4) (using 40mm graded stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed.
M&L for PCC type B0, (1:2:4) (using 12.5mm graded stone aggregates) as in coping, bed plates, apex stone incluing slightly rounded or chamferred angles and throating including necessary form work complete all as specified and directed.
Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor complete all as specified and directed
M&L for concealed point wiring with 1.5 Sqmm PVC(FRLS) insulated, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC rigid conduit medium grade of size not less than 20 mm dia ISI marked ivory white with all accessories such as tee, bend, joint cover etc/square Top blocks at junction for batten holders, ceiling rose etc screws, gutti/roul plugs PVC all as per site requirement including MS sunken boxes made out of ms sheet and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green for the following:-
For one light, fan point controlled by one switch
For one 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.110 here in before but for power point wiring using with 2.5 sqmm PVC (FRLS) insulated , unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green.
S&F switch piano type flush, single pole, one way, 5 Amp 230 Volt complete all as specified and directed
S&F socket outlet , 5 pin, 5 Amp flush, 230 Volt complete all as specified and directed
S&F switch piano type flush, single pole, one way,15 Amp 230 Volt complete all as specified and directed
S&F socket outlet 2 in 1, 6 pin, 5/15 Amp , flush type universal shuttered 230 Volt complete all as specified and directed
S&F ceiling rose, surface backlit, 63.5x48 mm three terminal complete all as specified and directed
S&F lamp holder pvc insulated with back plate suitable for Angle/Batten fitting with 9 Watt LED bulb complete all as specified and directed
S&F electronic double space rotary step type 5 speed regulator 120- 280 V complete all as specified and directed
S&F testing and commissioning of MCB SP 6-32 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
All as per Srl item No.119 above but SPN 32- 63 Amps, 240 V
S&F sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar incl of suitable size complete all as specified and directed
S&F LED TL fitting 20/18 watt for surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver long life corresion resistance impact proof surface mounting IP66 Lumanires PC housing in opeal finish coverwith high brighness complete all as specified and directed. Make Havells Cat Part No LHEXBLP7PN1W020, 4 feet/Bajaj cat part No BCLSB 20 WH/ CG Cat par No LCTC-18-CDL
S&F LED Bulk head designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed. Make - Havells cat part No LHEXCGP7UN5W013/BAJAJ cat part no BIBWP10WLED /CG cat part No LBHE-10-CDL.
S&F exhaust fans AC single phase 230/ 240 V of size 300 mm sweep metallic body complete all as specified and directed. Make - Havells TURBOJET/Bajaj MAXX AIR/Crompton EXHD300-6-1.
Supplying and laying cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross sectional area 16 sqmm, 2 core complete all as specified and directed
S&F ceiling Fan 1200 mm sweep and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed
M&L for provn of earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
S&F GI tubing of size 25 mm bore, medium grade, ISI marked with all GI fittings (medium grade) incl laid in trenches , floor etc complete all as specified and directed .
S&F GI tubing of size 50 mm bore, medium grade, ISI marked with all GI fittings (medium grade) incl laid in trenches , floor etc complete all as specified and directed .
S&F Gun metal Gate valve iron wheel head both end screwed of size 25 mm bore complete all as specified and directed .
Cutting existing GI tubing for alterations ,screwing existing tube size of 40 mm and 50 mm dia for new connection including earth work and clamp, neccessory fitting as per site required complete all as specified and directed ..
S&F double door metallic sheet metal enclosure DB double door(DPX-125 ) VTPN suitable for housing 100A MCCB as incomer 4 Way 415 Volts with 200 Amps rated bus bars complete all as specified and directed ..
S&F MCCB 100Amps 4 pole, suitable for 415 V breaking capacity 16 KA connected in wall/surface with wire and lugs complete all as specified and directed ..
S&F sheet metal enclosure DB double door, IP-43 when MCBs to be used TPN, 4 way, 240 V with 200 Amps rated bus bar of suitable size complete all as specified and directed ...
M&L for concealed sub main wiring with 4 single core PVC FRLS insulated, sheathed copper conductor stranded 1100 volt grade cable of size 6 sqmm drawn in and incl PVC casing caping of size not less than 25 mm dia ISI marked ivory white with all accessories such as tee, bend, joint cover etc PVC insulated, sheathed copper conductor stranded 1100 volt grade cable of size 6 sqmm cable as continuous earth lead including connecting in existing meter complete all as specified and colour coding of cables such as Phase-Red, Yellow & Blue Neutral-Black and Earth-Green
M&L for concealed sub main wiring with 2 single core PVC FRLS insulated, sheathed copper conductor stranded 1100 volt grade cable of size 4 sqmm drawn in and incl PVC casing caping/conduit of size not less than 20 mm dia ISI marked ivory white with all accessories such as tee, bend, joint cover etc PVC insulated, sheathed copper conductor stranded 1100 volt grade cable of size 4 sqmm cable as continuous earth lead complete all as specified and colour coding of cables such as Phase-Red, Neutral-Black and Earth-Green
S&F testing and commissioning of MCB TPN 50 - 63 Amps, 240 V, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. .
S&F metal clad box enclosure with socket plug top and MCB SP 20 Amps flush mounting enclosure with 2 pin and earth plug socket complete all as specified and directed.
S&F in repairs including testing of AC three phase static energy meter of accuracy class 1.0, 3X240V, 50Hz, with backlit LCD display of rating 10-60A. (measures & display KWH, KVAH, V, I, KW, PF, Hz, last month history of KWh & MD in KW) with special features like TOD, tamper logging, optical communication port & display in absence of power with transferent hinge type box complete all as specified and directed. Make:- HPL model No. TPPB1521130002ME01 or equivalent in L&T/Secure as approved by GE
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core complete all as specified and directed.
All as per Srl item No.140 above but of size 50 sqmm, 3.5 core.
All as per Srl item No.140 above but of size 35 sqmm, 3.5 core.
All as per Srl item No.140 above but of size 16 sqmm, 4 core.
Excavation in trenches in soft/ loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed. Note:- Punned thickness shall be measured and paid
M&L for brick sub class'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed
Supplying, laying and fixing in position galvanized iron pipe 50mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed
All as per Srl item No.147 above but 80mm dia
Taking down and re-fixing of ceiling fans complete all as specified and directed
M/s Vinod Kumar Korpal, Sagar
maharaja construction and suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .