| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC | L1 | Accepted-AOC L1 quoted rates are overall reasonable,hence Accepted | |
| 2 | L2₹34.6 L+₹1.7 L (5.30%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹34.8 L+₹1.9 L (5.67%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹36.0 L+₹3.1 L (9.35%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹36.3 L+₹3.4 L (10.5%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L5 | Rejected-AOC REJECTED |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
4 Jan 2020, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
REPAIR/ REPLACEMENT TO STREET LIGHTS,SECURITY LIGHTS, DG SETS, FIRE FIGHTING AND OTHER MISC ITEMS AT NCHC POWAI AND ULHASNAGAR UNDER GE(NW) BHANDUP MUMBAI
2019_MES_298551_2
8778/B
Open Tender
Civil Works
Item Rate
274 days
POWAi
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in Class D Cat b(i),c(vi)
9 documents required · 9 mandatory
₹500
GE (NW) BHANDUP
₹64,000
Yes
2 Apr 2020
13 Dec 2019
8 Jan 2020
13 Dec 2019
4 Jan 2020
23 Dec 2019
13 Dec 2019 - 18 Dec 2019
Amount
M&L Carrying out 'B' check for 82.5 KVA DG set all as per manufacturers instructions all as specified & directed. Note : cost includes the rates of diesel filters only but excluding spares and Engine oil.
All as per item No 1. above but 75 KVA capacity
All as per item No 1. above but 50 KVA capacity
All as per item No 1. above but 7.5 KVA capacity
Supply only Engine oil grade 20 W 40 for incorporation against item No. 01 Make : Castrol/Servo
Supply only coolant for DG set radiator complete all as specified.
Supply only oil filter suitable for 82.5 KVA DG set capacity as per existing size complete all as specified and diretced, Make- Kirloskar/Mahle/C&G/Leyland
All as per item No 7 above but 75 KVA capacity
All as per item No 7 above but 50 KVA capacity
All as per item No 7 above but 7.5 KVA capacity
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 82.5 KVA DG set
All as per item No 11 above but 75 KVA capacity
All as per item No 11 above but 50 KVA capacity
All as per item No 11 above but 7.5 KVA capacity
S&F in repairs of fan belt suitable for DG set of 50 to 82.5 KVA capacity complete all as specified and directed , Make- FENNER/Roflex/Vegrip
S&F in repairs of fan belt suitable for DG set 7.5 KVA capacity complete all as specified and directed , Make- FENNER/Roflex/Vegrip
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 82.5 KVA
All as per item No 17 above but 75 KVA capacity
All as per item No 17 above but 50 KVA capacity
All as per item No 17 above but 7.5 KVA capacity
Repairing radiator for 82.5 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and refixing on the chasses complete all as specified and as directed.
All as per item No 21 above but 75 KVA capacity
All as per item No 21 above but 50 KVA capacity
All as per item No 21 above but 7.5 KVA capacity
Material and labour for disconnecting / dismantling of self starter from DG set 82.5 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc, greasing and connecting , testing complete all as specified and as directed.
All as per item No 25 above but 75 KVA capacity
All as per item No 25 above but 50 KVA capacity
All as per item No 25 above but 7.5 KVA capacity
Material and labour for servicing and overhauling of dynamo including replacement of unsv parts such as carbon brush, armature winding, varnishing of coil and reassembling and fitted with the engine including testing complete of capacity 12 volts complete all as specified and directed.
Material and labour for painting of DG sets of 75 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Material and labour for painting of DG sets of 7.5 KVA including alternator, fuel tank complete with all accessories by scrapping throughly the existing corroded paint and applying two coats of synthetic enamel paint including marking SM/MES No complete all as specified and directed
Supply and fix in repair unserviceable Maintenance free battery 180 Ah 12 volts complet all as specified and directed. Make Exide/Amron
Supply and fix in repair unserviceable battery lead copper lead with brass terminal complete suitable for DG set 7.5 KVA to 82.5 KVA all as specified and directed. Make Exide/Amron
Dismantling and calibrating the fuel injector assembly from authorised dealer of capacity 82.5 KVA DG set complete allas specified and directed
All as per item No 34 above but 75 KVA capacity
All as per item No 34 above but 50 KVA capacity
All as per item No 34 above but 7.5 KVA capacity
Material and labour for replacement of asbestose rope 6mm dia complete all as specified and directed.
Supply and fixing in repairs electronic based generator controller unit model No GCU101 suitable for 50 KVA generator set including testing complete all as specified and as directed.
Dismantling the UNSV Automatic voltage Regulator of the 75 KVA DG set and replacement of the same with new as per existing make and size and fixing and testing complete
Taking down HPSV / MH street light fitting and Supply and fix LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 6500 lumens with maximum system wattage 60/65W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 110lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters all as specified. Make: Philips BRP062 LED 65 CW SLA S1 PSU Or Keselec / Osram
Taking down HPSV / MH/LED street light fitting and Supply and fix LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 8200lumens with maximum system wattage 82 W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 110lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Make- Similar to Philips BRP062 LED 82 CW SLA S1 PSU or Keselec / Osram
Supply & fix in repairs LED post top lattern fitting 40 watts made out of cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete. Make PHILIPS/WIPRO/CROMPTON
Taking down unserviceable security light fitting and Supply and fixing LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 3000 lumens with maximum system wattage 25W, external built proper heat sinks and polycarbonate housing ensuring IP66 & IK08 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT 5700, CRI>70, PF >0.95, 4kV surge protection(inbuilt) with optional surge protection of 10kV, Class B servicability, operating voltage of 140-270VAC. The fixture should comply with the parameters as per IS10322 and IEC60598 . Company LOGO shall be Engraved. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Make - Philips BRP046 LED 30 CW MR S1 PSU GR or Orsram / Keselec including provision of suitable size pipe for bracket of 1.2 mtr complete all as specified.
Supply and drawing through the pole for making connectiion to the light fittings single core PVC insulated and sheathed heavy duty 1100 volt grade multistranded copper conductor (FRLS) cable 2.5 sqmm complete all specified and directed
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 150 x 140 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to wall all as specified and directed Make : Sintex/national
Taking out existing terminal box and S&F Pole mounting type weather proof FRP terminal box of size 250 x 175 x 100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and aluminium bus bar for single phase and neutral (Three terminals) for cable in cable out entire complete. Terminal box to be fixed to street light pole with suitable G I iron flat of size 25 x 3 mm clamps fixed with GI Bolts, nuts and washer of suitable sizes all as specified and directed Make : Sintex/national
Supply and fixing LED Flood Light with minimum 21000 Lumens (at system level ).The luminaires housing shall be made of non-corrosive high pressure die cast aluminium with corrosion resistant powder coating, MCPCB; U-shaped bracket; Anti-dust exposed Lens, Impact resistance IK 08, IP66, system Power: 175W, Integrated Driver Efficacy:>90%, THD<10%, Life L70@50K Hrs, power factor>0.95; Color temp: 5700K, CRI>70; SDCM<5; The driver shall be BIS registered with outdoor type potted driver. Minimum luminaire efficacy 120 lumen/Watt at system level, operating voltage of 120-270V; Surge protection of 10 KV, lighting distribution options of Narrow/Asymmetrical wide / Symmetrical wide, Class B Serviceability, Electrical safety & Conformation standards of luminaire: The luminaire should have graduation disk for aiming, LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. There should be mandatory coating available for extra protection in harsh environment such as salt atmospheres (harbours, coastal areas etc). BVP483 LED 210 CW complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed
Supply and fixing in repairs 3 pole power contactor 32 amps, coil voltage 230 volts complete all as specified and directed
Supply and fixing in repairs 3 pole power contactor 40 amps, coil voltage 230 volts complete all as specified and directed
Supply and fixing in repairs analog timer switch 3P module, 24 Hrs programme complete all as specified and directed
Supply and fix battery charger 230 volt,50 Hz AC input and 12 volt,10 Amp DC output and having constant current and float charging control for battery all as specified and directed
Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Supply and fix in repairs pipe bracket made out of 25/35 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Supply and lay cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core
Supply and lay cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm x 4 core
Supply and lay cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm x 3.5 core
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
Supply and spreading sand in trenches as cushioning to under ground cable on top and bottom of cable all as specified.
M&L in repairs of GI pipe 80 mm dia light grade with all fittings for cable protection .
M&L in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection .
Taking down unserviceable LT cable complete all as specified and directed
Supply and fix in repairs of MCCB 100 Amps 4 Pole, with breaking capacity 25 KA complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 415V, abjustable type, 50Hz 250 Amps 36 KA with sheet metal enclosure complete all as specified and directed .
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified and directed by Engr in Charge
M&L for Preparation of old exposed surface of LT PCC poles of any type / size with bracktes clamps etc and painting with one coat of snomsame paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified and directed by Engr in Charge
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22, 9 metres long complete all as specified and directed
PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified.
PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified.
Repair/Routine maintenance including carrying out daily check of fire alarm/fire fighting system complete with electronic control panel consisting of 02 zones in P/267 and P/268 buildings (G+16 floors) ie 17 stories including attendance of alarm personnel to attend the fire alarm system faults, testing, checking including replacement of unserviceable components other than mentioned in schedule “A” The fire alarm system consisting the following:- (a) Indicator (b) Electronic hooter (c) Manual call point (d) Smoke detector (e) Heat detector (f) Electronic fire control panel (g) Main/Zone cards (h) Battery of Fire panel DC supply (J) All wiring and cable connections (k) Fire diesel pump (l) Fire pump (m) Booster pump
Supplying, installing, testing and commissioning cast iron body, ISI marked,BUTTERFLY VALVE as per IS 13095, ISI Marked with necessary fittings as per specification. Details : The Butterfly valve shall suitable for waterworks and tested to minimum of 20 kg/cm2 pressure. The body shall of cast iron conforming to IS:210 in circular shape and of high strength to take the minimum water pressure of 10kg/cm2 . The disk shall be heavy duty cast iron with anticorrosive epoxy or nickel coating Make- Audco/Kirloskar/Honeywell Note : i) The valve seat shall be of high grade elastomer or nitrile rubber. The valve in closed position shall have complete contact between the seat and the disc thoughout the perimeter. the elastomer rubber shall have a long life & shall not give away on continuous water pressue. The shaft shall be on EN 8 grade carbon steel. ii) the valve shall be fitted between two flanges on upper side of pipe flanges. The valve edge rubber shall be projected outside such that they are wedged within the pipe flanges to prevent leakages.iii) The valves shall be suppied with manual gear operated openin/closing system by lever. For 150 mm Dia
All as per Item No 74 here-in-before but for 100 mm dia
All as per Item No 74 here-in-before but for 80 mm dia
All as per Item No 74 here-in-before but for 65 mm dia
Supply and fixing in repair of Y stainer with necessary fittings, flanges, nut bolts etc as per specification. The "Y" type strainer shall have cast iron body confirming to IS 210 FG 200 Perforaed sheet shall be of brass or strain less steel 304. The Screen open area shall be minimum Four times cross sectional area at inlet. The Strainer shall be suitable for MIN. flow of 300 LPM at 10kg/cm2 sq pressure. The flanges shall be to IS 1538. The nut bolt sand washers shall be galvanised confirming too IS 1367. The pressure loss shall not be more than 0.5 kg/cm2 sq. The Hydraulic Testing shall done at 21kg/cm sq for the duration of Two hours for 150 mm Dia
All as per Item No 75 here-in-before but for 100 mm dia
Supply & fixing in repair presure gauge glycerine filled with 15mm inlet connection dial size 100 mm of pressure range 0.21Kg/cm sq. with 15mm isolation valve with G.I. nipple all as specified
Supply and fixing in repair pressure switches with adjustable pressure range from 1 to 10 bar with 15mm isolation valve with GI Nipple all as specified.
Supply and fixing in repair approved quartezoid bulb 15mm dia sprinkler pendent type , IS 15106 chrome plated crossette plate, with temperature rating 68 degree with universal deflector as approved by T.A.C complete with all necessary connections complete all as specified and directed.
All as per Item No 78 here-in-before but with temperature rating 79 degree
Supply and fixing Bronze Orifice with 12mm thick disc with tag on plate mentioning dia of orifice for sprinkler system to control the pressure including rubber gasket packing, bolts, nuts washers all complete as per specified and directed
S&F ball valve with brass speindle of 25mm dia complete all as specified
S&F ball valve with brass speindle of 50 mm dia complete all as specified
Supply and Fix in repairs outside hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600nun X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside and concealed in wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directed
Supply and Fix in repairs internal hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800 mm x 600mm x 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside fixed on wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directedall as specied and directed.
Supply and Fix in repairs fire fighting RRL hose pipe of 63mm, ISI marked, IS 636(type A), 15m long fitted with male and female gun metal coupling ISI marked, IS 903 complete all as specied and directed.
Supply and Fix in repairs gunmetal branch pipe with nozzle suitable for 63 mm dia RRL hose pipe, ISI marked, complete all as specied and directed.
Supply and Fix in repairs fire hydrant landing valve GM single outlet hydrant morris pattern oblique type 63 mm size confirming to IS 5290 with PVC blank cap and MS or GI chain in an approved manner.
Supply and Fix in repairs two way fire brigade inlet, ISI marked, IS 5290, with non return valve, of gun metal size 63mm dia and including all fixing accessories complete all as specified and directed.
Supply and Fix in repairs four way brigade inlet, ISI marked, IS 5290,with non return valve of gun metal size 63mm dia and including all fixing accesorries complete all as specified and directed.
Repair and maintenance of 100 HP fire service main pump multi stage having 2280 LPM at 90 mtrs head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100HP diesel engine including servicing by replacing unserviceable items of gland packing, bearings and charging lubricants for smooth running including servicing of 100 hp diesel engine by replacing filters, lubricant oil including defective parts like coupling, oil air filters, servicing of radiator, replacement exhaust gasket, replacement of diesel supply and return pipes from tank to engine, battery leads and checking of chaging circuit complete including base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed .
Repair and maintenance of 100HP fire service main pump multi stage having 2280 LPM at 90 mtrs head multi stage pump of horizontal split casing running at 1450 RPM coupled with 100HP AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pump room of approved colour after preparation of existing surface complete all as specified and directed .
Repair and maintenance of 5.5 HP fire service jockey pump multi stage having 180 LPM at 90 mtrs head multi stage pump of horizontal split casing running at 2900 RPM coupled with 5.5 HP AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed.
Repair and maintenance of fire service booster pump multi stage having 900 LPM at 36 mtrs head ,horizontal split casing running at 2900 RPM coupled with AC induction motor including servicing by replacing unserviceable items of gland packing, bearings, gaskets, nuts, bolts and charging lubricants for smooth running including painting of pumpset, base frame and pipe lines upto inside pumproom of approved colour after preparation of existing surface complete all as specified and directed.
Material and labour for replacement of un serviceable timer of starter, range 9 to 30 sec adjustable type voltage 415 V all as specified and directed by Engr-in- Charge.
Material and labour for repalcement of un serviceable single phase preventer , 415 V 50Hz including electric connection all as specified and directed by Engineer-in-Charge. Make Minilec.
S&F in repair MPCB (motor protection circuit breaker), 3 Phase, 415 Volts, 50 Hz, contractor type - MO 50 suitable of 75 HP pumps complete all as specifed and directed Make- L&T/Schneider/Siemens
S&F in repair soft starter Model No CSXi-030-41, 3 Phase 60 Amp with auxiliary 30 VDC for withstanding current 5000A RMS 575 V AC Maximum in panels with proper wiring complete all as specified and directed. Make L&T Model No CSXi-030-41 or ABB/Schneider
Supply and fix in repair barrel type HRC Fuse 2 to 32 Amps complete all as specifed
Supply and fix in repair barrel type HRC Fuse 40 to 63 Amps complete all as specifed
Supply and fix in repair maintenance free SMF type lead acid battery duly charged 12 Volts, 24 Ah complete all as specifed. Make- Exide/Amron
Supply and fix in repairs Foot valve cast iron body both ends flanged suitable for 150mm bore CI pipe connection all as specified and directed Make -Kirloskar/Kartar/SIR/AUDICO
Supply Only analogue addressable multisensor detector (Photo + Thermal) with base with galvanised steel, back box and all mounting accessories complete as specifed and directed Make- GE Edwards Model : SIGA-PHS+SB or equivalent siemens/ system sensor/Safex
Supply Only analogue addressable heat detector, with galvanised steel back box all mounting accessories complete as specifed and directed Make- GE Edwards Model : SIGA-PHS+SB or equivalent siemens/ system sensor/Safex
Supply addressable Dual Action Manual Pull staions inside for providing MS box of suitable size for concealing the manual call point in the wall and with mounting accessories all as specified Make- GE Edwards Model : SIGA-270 or equivalent siemens/ system sensor/Safex
Supply addressable Monitor Modules in a suitable gavanised steel junction box with mounting accessories all as specified Make- GE Edwards Model : SIGA-CT1 or equivalent siemens/ system sensor/Safex
Supply addressable control Module with 230 V 2 A where required in a suitable gavanised steel junction box with mounting accessories all as specified Make- GE Edwards Model : SIGA-CR or equivalent siemens/ system sensor/Safex
Supply addressable control Module for Hooter in a suitable gavanised steel junction box with mounting accessories all as specified Make- GE Edwards Model : SIGA-CR or equivalent siemens/ system sensor/Safex
Supply Electronic Hooter include provide MS box suitable size for concealing the hooter in the wall mounting accessories all as specified Make- GE Edwards Model : R HD or equivalent siemens/ system sensor/Safex
Shree Ayyappa Engineering
cooltech engineering services
GRAND SERVICES
R J ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .