Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | ₹20.1 L Quoted ₹20.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹21.4 LRejected-Finance | ₹21.4 L | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹24.4 LRejected-Finance DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹24.4 L | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹24.4 LRejected-Finance | ₹24.4 L | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹24.8 LRejected-Finance | ₹24.8 L | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | SRI VARADA CONSTRUCTIONS L1 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L6 | SRI SAI RAM ENTERPRISES L5 | Krithi constructions L2 | SRI BHAVANI ENTERPRISES L4 | B SRINIVAS L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the existing unserviceable main switch / metal socket / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. | 81 | EACH | 9 ₹729 | 20 ₹1,620 | 10 ₹810 | 11 ₹891 | 10 ₹810 | 50 ₹4,050 |
| 2.00 | S &F in replacement vertical type TPN DB 12 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 2 | EACH | 8,999 ₹17,998 | 8,300 ₹16,600 | 11,500 ₹23,000 | 9,250 ₹18,500 | 9,200 ₹18,400 | 6,000 ₹12,000 |
| 3.00 | S &F in replacement vertical type TPN DB 8 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 5 | EACH | 7,000 ₹35,000 | 7,500 ₹37,500 | 10,200 ₹51,000 | 7,300 ₹36,500 | 7,800 ₹39,000 | 8,000 ₹40,000 |
| 4.00 | S &F in replacement vertical type TPN DB 6 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 2 | EACH | 6,500 ₹13,000 | 7,000 ₹14,000 | 9,500 ₹19,000 | 6,300 ₹12,600 | 7,200 ₹14,400 | 6,500 ₹13,000 |
| 5.00 | S &F in replacement vertical type TPN DB 4 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 8 | EACH | 5,600 ₹44,800 | 6,000 ₹48,000 | 8,900 ₹71,200 | 5,650 ₹45,200 | 6,200 ₹49,600 | 6,000 ₹48,000 |
| 6.00 | S&F in replacement MCB DB double door TPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | 2 | EACH | 2,800 ₹5,600 | 4,000 ₹8,000 | 3,100 ₹6,200 | 2,890 ₹5,780 | 3,100 ₹6,200 | 1,500 ₹3,000 |
| 7.00 | S&F in replacement MCB DB double door TPN 6 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | 2 | EACH | 2,799 ₹5,598 | 3,700 ₹7,400 | 2,950 ₹5,900 | 2,890 ₹5,780 | 3,000 ₹6,000 | 1,500 ₹3,000 |
| 8.00 | S&F in replacement MCB DB double door TPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | 4 | EACH | 2,400 ₹9,600 | 3,675 ₹14,700 | 2,800 ₹11,200 | 2,630 ₹10,520 | 2,600 ₹10,400 | 2,000 ₹8,000 |
| 9.00 | S&F in replacement MCCB 415V,16KA, 4 pole, 200 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | 2 | EACH | 3,200 ₹6,400 | 4,000 ₹8,000 | 9,000 ₹18,000 | 3,150 ₹6,300 | 4,000 ₹8,000 | 13,972 ₹27,944 |
| 10.00 | S&F in replacement MCCB 415V,16KA, 4 pole, 160 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | 12 | EACH | 3,000 ₹36,000 | 3,800 ₹45,600 | 7,000 ₹84,000 | 3,300 ₹39,600 | 3,500 ₹42,000 | 4,130 ₹49,560 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
12 May 2026, 6:00 pmClosed
GE MCEME SECUNDERABAD
GARRISON ENGINEER MCEME, MCEME CAMPUS, TRIMULGHERRY (POST) SECUNDERABAD - 500015
REPAIRS MAINT OF VTPN MCBDB SUB MAIN WIRING ALONG WITH ALL CONNECTED ITEMS OF ZONE I AREA UNDER GE MCEME SECUNDERABAD
2026_MES_760438_1
8748/E8
Open Tender
Civil Works
180 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹50,000
Yes
30 Jun 2026
15 Apr 2026
14 May 2026
15 Apr 2026
12 May 2026
29 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Taking down the existing unserviceable main switch / metal socket / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. | - | EACH | - | - | |
S &F in replacement vertical type TPN DB 12 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - | |
S &F in replacement vertical type TPN DB 8 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - | |
S &F in replacement vertical type TPN DB 6 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - | |
S &F in replacement vertical type TPN DB 4 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - | |
S&F in replacement MCB DB double door TPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | - | EACH | - | - | |
S&F in replacement MCB DB double door TPN 6 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | - | EACH | - | - | |
S&F in replacement MCB DB double door TPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | - | EACH | - | - | |
S&F in replacement MCCB 415V,16KA, 4 pole, 200 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | - | EACH | - | - | |
S&F in replacement MCCB 415V,16KA, 4 pole, 160 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | - | EACH | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_851783.xls
BOQ • 2.19 MB
Tender8748.pdf
Tender Documents • 0.78 MB
Download all tender documents and submit your bid