| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.4 L+₹72,274 (3.49%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.4 L+₹3.6 L (17.5%)Rejected-Finance DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹24.4 L+₹3.7 L (18.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹24.8 L+₹4.1 L (19.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | SRI VARADA CONSTRUCTIONS L1 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L6 | SRI SAI RAM ENTERPRISES L5 | Krithi constructions L2 | SRI BHAVANI ENTERPRISES L4 | B SRINIVAS L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the existing unserviceable main switch / metal socket / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. | 81 | EACH | 9 ₹729 Lowest | 20 ₹1,620 | 10 ₹810 | 11 ₹891 | 10 ₹810 | 50 ₹4,050 |
| 2.00 | S &F in replacement vertical type TPN DB 12 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 2 | EACH | 8,999 ₹17,998 | 8,300 ₹16,600 | 11,500 ₹23,000 | 9,250 ₹18,500 | 9,200 ₹18,400 | 6,000 ₹12,000 Lowest |
| 3.00 | S &F in replacement vertical type TPN DB 8 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 5 | EACH | 7,000 ₹35,000 Lowest | 7,500 ₹37,500 | 10,200 ₹51,000 | 7,300 ₹36,500 | 7,800 ₹39,000 | 8,000 ₹40,000 |
| 4.00 | S &F in replacement vertical type TPN DB 6 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 2 | EACH | 6,500 ₹13,000 | 7,000 ₹14,000 | 9,500 ₹19,000 | 6,300 ₹12,600 Lowest | 7,200 ₹14,400 | 6,500 ₹13,000 |
| 5.00 | S &F in replacement vertical type TPN DB 4 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | 8 | EACH | 5,600 ₹44,800 Lowest | 6,000 ₹48,000 | 8,900 ₹71,200 | 5,650 ₹45,200 | 6,200 ₹49,600 | 6,000 ₹48,000 |
| 6.00 | S&F in replacement MCB DB double door TPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | 2 | EACH | 2,800 ₹5,600 | 4,000 ₹8,000 | 3,100 ₹6,200 | 2,890 ₹5,780 | 3,100 ₹6,200 | 1,500 ₹3,000 Lowest |
| 7.00 | S&F in replacement MCB DB double door TPN 6 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | 2 | EACH | 2,799 ₹5,598 | 3,700 ₹7,400 | 2,950 ₹5,900 | 2,890 ₹5,780 | 3,000 ₹6,000 | 1,500 ₹3,000 Lowest |
| 8.00 | S&F in replacement MCB DB double door TPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | 4 | EACH | 2,400 ₹9,600 | 3,675 ₹14,700 | 2,800 ₹11,200 | 2,630 ₹10,520 | 2,600 ₹10,400 | 2,000 ₹8,000 Lowest |
| 9.00 | S&F in replacement MCCB 415V,16KA, 4 pole, 200 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | 2 | EACH | 3,200 ₹6,400 | 4,000 ₹8,000 | 9,000 ₹18,000 | 3,150 ₹6,300 Lowest | 4,000 ₹8,000 | 13,972 ₹27,944 |
| 10.00 | S&F in replacement MCCB 415V,16KA, 4 pole, 160 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | 12 | EACH | 3,000 ₹36,000 Lowest | 3,800 ₹45,600 | 7,000 ₹84,000 | 3,300 ₹39,600 | 3,500 ₹42,000 | 4,130 ₹49,560 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
5 May 2026, 6:00 pmClosed
GE MCEME SECUNDERABAD
GARRISON ENGINEER MCEME, MCEME CAMPUS, TRIMULGHERRY (POST) SECUNDERABAD - 500015
REPAIRS MAINT OF VTPN MCBDB SUB MAIN WIRING ALONG WITH ALL CONNECTED ITEMS OF ZONE I AREA UNDER GE MCEME SECUNDERABAD
2026_MES_760438_1
8748/E8
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹50,000
Yes
30 Jun 2026
15 Apr 2026
7 May 2026
15 Apr 2026
5 May 2026
29 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Taking down the existing unserviceable main switch / metal socket / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. | - | EACH | - | - |
| - | S &F in replacement vertical type TPN DB 12 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - |
| - | S &F in replacement vertical type TPN DB 8 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - |
| - | S &F in replacement vertical type TPN DB 6 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - |
| - | S &F in replacement vertical type TPN DB 4 way double door for incoming MCCB TPN 415 volts AC 3 phase 50 Hz 16 KA, 125 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/ABB. | - | EACH | - | - |
| - | S&F in replacement MCB DB double door TPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | - | EACH | - | - |
| - | S&F in replacement MCB DB double door TPN 6 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | - | EACH | - | - |
| - | S&F in replacement MCB DB double door TPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. MAKE: HAVELLS/Schneider/Standard/C&S/ABB | - | EACH | - | - |
| - | S&F in replacement MCCB 415V,16KA, 4 pole, 200 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | - | EACH | - | - |
| - | S&F in replacement MCCB 415V,16KA, 4 pole, 160 amps suitable for VTPN DB all as specified and directed. MAKE: HAVELLS/Schneider/Standard/C&S/Legrand | - | EACH | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_851783.xls
BOQ • 2.19 MB
Tender8748.pdf
Tender Documents • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .