Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.8 L+₹19,204 (1.23%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹16.9 L+₹1.4 L (8.76%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹22.2 L+₹6.6 L (42.5%)Rejected-Finance | L4 | Rejected-Finance Rejected due to highest rate quoted | |
| 5 | L5₹28.9 L+₹13.4 L (85.9%)Rejected-Finance NOT FOUND | L5 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
17 Jul 2023, 6:00 pmClosed
GE (AF) Gurgaon
GE (AF) Gurgaon
REPAIR REPLACEMENT AND MAINT OF LT PANELS EARTHING LIGHTENING ARRESTERS UNDER GROUND CABLES APFC PANELS TPN DBs SERVICE CONNECTIONS AND OTHER EM ALLIED WORKS AT AF STN ARJANGARH UNDER GE AF GURGAON
2023_MES_604299_1
GE/GUR-/NIT-11/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹64,000
18 Aug 2023
19 Jun 2023
19 Jul 2023
19 Jun 2023
17 Jul 2023
3 Jul 2023
Amount
Excavation of soft/loose soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified and as directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and as directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and as directed.
M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and as directed.
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete all as specified and as directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and as directed.
Supply and fix on load "AUTOMATIC MOTORIZED CHANGE OVER SWITCH" of capacity 400 A, 4 Pole , 415 Volts, 50 Hz as per IEC-60947, complete with add on block bridge with function of auto and manual switch and with handle to operate manual including necessary connection with contactors and delay timer complete all as specified and as directed. Cat No. CX4 C04-400 of Make L& T or equivalent out of makes spd in list of makes.
M&L for Maintenance / repairs to APFC panels, 3 phase AC 415 V, by skilled technician and replacement of unserviceable spares as specified below for capacities 40 to 200 KVAR including replacement of short circuited copper conductor cables with appropriate gauge PVC insulated stranded copper conductor cables and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified powerfactor complete all as specified and as directed.
Supply and install capacitor metalized poly propylene ultra heavy duty (LTXL) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of the following capacity complete all as specified and as directed. Make : EPCOS/L&T/Havells/Siemens :-
(a)25 KVAr
(b)20 KVAr
(c)10 KVAr
(d) 5 KVAr
(e) 2KVAr
M & L for Restrainingre of LT over head line single ACSR conductor comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and as specified.
Trimming of tree branches upto 11m from ground level all along the over head electric supply lines, to clear all branches maintaining a clear distance of 1.5m from the conductors. The maximum average dia of branches shall not exceed 20cm. After trimming the cut pieces and branches are cleared from the road upto a distance 200m complete all as specified and as directed. Note: (a) Required tools, ladder, Safety equipment etc. shall be arranged by the firm. (b) Area wise shut down to feeders shall be given on one day notice upto 4hrs.
Supply ,install testing and commisioning of maintenance free chemical earthing system conforming to IS: 3043 using 77mm dia 3000mm long copper rod with exothermic T point rod with long copper strip of size 50mm x 6 mm and 90 mm dia terminal pipe of thickness 1.6 mm and 3000 mm long with copper test certifcate 99.99%. The ground enhancing compound made of Marconite conductive aggregate (consist of Marconite resin-based cements, adhesive and gypsum plasters) shall not be less than 45 kg. The electrode shall be provided on its top with an earth termination clamp made out of electrolytic grade copper for connecting earth continuity conductor with copper wire. PCC chamber of size 300x300x300 mm with cover shall be provided on the top of the earth system on 100 mm thick PCC 1:3:6 bed concrete . The chamber shall burried in ground with top edge projecting upto 75 mm from ground surface complete all as specified and directed.
Note for item No 14:- . (i) The quoted rate shall include cost of copper strip 50mm x 6 mm upto 7.5 m length and bore in hard/disintegrated rock. . (ii) The earth resistance shall not be more than 01 ohm upto 5 years and contractor shall also deposit the security amount of Rs 2000/- per earthing as a gurrenttee for 5 years. . (iii) the size of bore should not be less than 1500 mm dia. MAKE-SN Engineering or equivalent from Marconite conductive aggregate.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES Schedule pt-I 1991, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as spd and as directed. Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
All as per item No 15 above but with main earth lead 32 x 6 mm galvanised iron strip.
All as per item No 15 above but with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead.
M & L in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete all as specified and as directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
Supply and fix epoxy insulators 25 mm dia base with suitable screws complete for fixing AL strip if size 25x3.15 mm complete all as specified and as directed.
Supply and fix porcelain insulator (white colour) for running of GI/Aluminium/Copper strips of size 32/20/25 mm including suitable size of screws for fixing vertically/horizontal plane at any height and making suitable size holes on strips including nut/bolts/wahsers etc complete all as specified and as directed.
M & L for Air termination of Lighting conductors, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed .
M & L for Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed .
M&L for pole painting, concrete pole with 02 coat of wheather exposed dust proof "apex" emulsion, pole height should be 9/11 mtr. Painting should be done from top to bottom at ground level. Bottom portion of the pole upto 1.50 m from top of the copping with one coat of synthetic enamel paint with marking pole numbers & marking three blue & two white strips width 25 cm by fluorescent paint complete all all as specified and as directed .
Supply and fix in repair ACB 4 pole 415 volts , 630 amps , AC 50 Hz with breaking capacity 50 KA conforming to IS/IEC-60947-2 with themal magnetic release and manual drawout type ( Thermally adustable type ) inclding electrical connection as per site requirement complete all as specified and as directed .
Supply and fill of back feel compound in earth pit complete all as specified and as directed . Make - S N Engineering or Equivalent as approved by GE. (This item shall not be operated with new earthings).
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 4 core complete all as specified and as directed.
All as per item No. 29 but Size 16 Sqmm X 4 core.
All as per item No. 29 but Size 25 Sqmm X 4 core.
All as per item No. 29 but Size 50 Sqmm X 3.5 core.
All as per item No. 29 but Size 70 Sqmm X 3.5 core.
All as per item No. 29 but Size 95 Sqmm X 3.5 core.
All as per item No. 29 but Size 120 Sqmm X 3.5 core.
All as per item No. 29 but Size 240 Sqmm X 3.5 core.
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete all as specified and as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete all as specified and as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete all as specified and as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 300 sq mm complete all as specified and as directed.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC pole complete all as specified and as directed.
Supply and fixing prestressed concrete pole 9 meters long 102 mm x 152 mm at top and 102 mm x 289 mm at bottom of class 10 complete, Including disconnecting and taking out old damage PCC pole all as directed . Note for item no - ___ & ___ -Earth work and PCC shall be measured and paid separately as these respectively.
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 630 amps in open execution to be fixed in existing panel with suitable size nut/bolts and complete all as directed.
Supply and fix ON load four pole changeover switch with front handle operated of 4 pole 415 volt 50 Hz 400 amps in open execution to be fixed in existing panel with suitable size nut/bolts and complete all as directed.
M & L for Painting of steel pole with cross arms, clamp of any length and shape for LT overhead line with single coat of aluminium paint including preparation of the existing surface including marking pole numbersand marking three blue & three white bends width 20 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height complete all as specified and as directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for LT size 20 X 15 Cm fix in repairs complete all as specified.
M& L for Pin type, porcelain, vitreous, white, brown or green insulator, 100mm height, 65 mm dia for 1100 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, fixed in repairs complete all as specified and as directed.
M&L for Shackle type insulator from LT overhead line and S&F new Shackle type, porcelain, vitreous, white, brown or green insulators 100mm dia and 115 mm height for working pressure 1100 volts including galvanised mild steel strap 31 x 3mm size, washers, 14mm dia insulator bolts, washers & nuts , fixed in repairs complete all as specified and as directed.
M& L for loop type, porcelain, vitreous, white, brown or green insulator, 65 x 90 mm , clearence of hole 16 mm for 1100 volts grade including fixed in repairs complete all as specified and as directed.
M&L in repair/replacement for LT line PVC Spacers for the following sizes :-
(a) Spacer for two wire.
(b) Spacer for three wire.
(c) Spacer for four wire.
(d) Spacer for five wire.
Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed. Note: The make of MCCB shall be as per list of makes and in case necceasry alteration required to fix the same at no extra cost shall be done by the bidder.
All as per item No 51 above but MCCB TP 125 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader.
All as per item No 51 above but MCCB TP 250 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader.
All as per item No 51 above but MCCB TP 400 Amps, 415 Volts, 36 KA, 50 Hz complete with extended terminals and PVC spreader.
All as per item No 51 above but MCCB TP 630 Amps, 415 Volts, 50 KA, 50 Hz complete with extended terminals and PVC spreader.
All as per item No 51 above but 4 Pole, 125 Amps, 415 V, 25 KA, 50 hz complete with extended terminals and PVC spreader.
All as per item No 51 above but 4 Pole, 200 Amps, 415 V, 25 KA, 50 hz complete with extended terminals and PVC spreader.
All as per item No 51 above but 4 Pole, 400 Amps, 415 V, 36 KA, 50 hz complete with extended terminals and PVC spreader.
All as per item No 51 above but 4 Pole, 630 Amps, 415 V, 50 KA, 50 hz complete with extended terminals and PVC spreader.
M & L for PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire , two single core cable of 10 Sqmm , complete all as specified and as directed by Engr-In-Charge.
S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 4 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and as directed by Engr-in-Charge.
S & F in repair sub main wiring for circuit of size 4 sq mm 2 core (FRLS) alongwith earth wire of 2.5 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair TPN DB's 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and as directed by Engr-In-Charge.
All as per item No. 63 above but of 4 way and suitable for housing of 100 A/63 A MCCB as main incoming.
S & F MCCB 125 Amps capacity, 4 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 8 way TPN DB complete all as specified and as directed.
All as per item No. 65 above but capacity 100 Amps, fixed thermal and magnetic release, 4 Pole, 25 KA suitable to be fixed in 4 way TPN DB.
Suply and fixing 240 V, 10 KA, 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity SP 5-32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed by Engr-In-Charge.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 2 core complete all as specified and as directed by Engr-In-Charge.
Supply, Fabrication, installation, testing and commissioning in repair of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and as directed and comprising of the following:-
(a) Bus bar Aluminium - 400 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. (b) MCCB 250 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No. (c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal setting as out going- 06 Nos. (e) MCB SP 63 Amps, 10 KA, 'B' Series- 12 Nos (f) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO (g) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 01 Set
M&L for searching fault location of HT/LT UG cable 11000/415 Volts laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with frequency distance calculator etc incl transportation of machinery. Excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re-fixing cables with lugs complete all as specified and as directed by Engr-In-Charge.
Supply, Fabrication, installation, testing and commissioning in repair of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified & as directed by Engr-In-Charge and comprising of the following :-
(a) Bus bar Aluminium - 600 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. (b) MCCB 400 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No. (c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal setting as out going- 09 Nos. (d) MCB SP 63 Amps, 10 KA, 'B' Series (e) Digital multifuctional meter (Make : L&T), 4410 Series, Cat No. WL441010OOOO (f) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 01 Set of three
S & F pole box for street light dust and vermin proof make : Sintex model GSJB 3020 or equivalent in Universal complete with aluminum bus bar 04 nos. of capacity 200 amps on epoxy insulators incl one MCB SP C series 06 amps 10 KA capacity-01 nos. for Security light connection including suitable size PVC glands-02 nos at bottom for cable entry and exit complete all as specified and as directed. Make Shall be : Sintex/Universal/National. Note : MS Clamps shall be measured and paid seperately under relevant items.
Supply, Fabrication, installation, testing and commissioning of CPRI approved outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame, 04 Nos legs made out of 50 x 50 x 5 mm MS angle not less than 600 mm with MS plate of square size 80 mm x 80 mm at bottom of legs, 2 mm thick CRCA sheet (Make -Tata/ sail) ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thick ness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements complete ,sheets bend, folded, cut with CNC machine for the accuracy of diamensions +/-0.5%, duly powder coated with siemens grey colour after chemical trteatment, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars MCCB's with suitable size copper bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and
Supply and fillling coolent suitable for DG set complete all as specified and as directed. Make-: Castrol / Servo / HP
Supply in replacement, Engine oil, multi grade 20 W 40 or equivalent grade of make : Castrol / Servo / HP complete all as specified and as directed.
M& L for removal of old u/s RCC cable trench cover of any size and any description complete all as specified and as directed.
S&F in repair for mild steel plates (plain or chequered) of Grade Fe 410-W (Gde-E-250) Quality 'A' for covering the cable trenches/cable ducts of described size complete with arrangement of lift hooks with provision of four Nos holes complete all as specified and as directed.
Supply and fixing street light brackets made out of GI tubing light grade, 40 mm bore 1200 mm long bent to sahpe at 120 degree, fixed on pole by providing MS clamp made up to flat iron 50 x 6 mm including nuts and washer of suitable size, fixed in repairs complete all as specified and as directed.
Supply and filling distilled water for top in battery of any type any capacity complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 12 ways 240 V complete all as specified and as directed .
S&F in replacement of sheet metal enclosure double door suitable for SPN distribution boards when MCBs to be used having 200Amp rated bus bar 8 ways 240 V complete all as specified and as directed.
S&F in replacement of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 4 ways 240 V complete all as specified and as directed .
S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 10-32 complete all as specified and as directed.
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, complete all as specified and as directed.
S&F in replacement MCB SPN 5 to 40 Amps, 240 volts, curve 'C', breaking capacity 10 KA, complete all as specified and as directed.
S&F in replacement MCB SPN 50 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA, complete all as specified and as directed.
S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 2'x2' fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser (40 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including all accessaries complete all as specified and as directed.
Supply and fix in replacement double door TPN DBs 4 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and as directed.
S & F in replacement with MCB TPN 32 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed .
S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed .
S & F in replacement with MCB TPN 100 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed.
Supply and fixing in repair LED street light fittings 70 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including therma; management in multiple optics complete with IP 65/66 protection complete with provision of twin core teisted copper wire 23/0.0076 upto security light from pole loop box . Cat No. ENDURACITYLINERNEOSL70W LED757PASYBOTG of Make Hevells or equivalent in Bajaj/Wipro/Crompton.
B S ENGINEERS AND ASSOCIATES
M/S Rohit Enterprises
A B K Enterprises
shiv shanker enterprises
M/s Navansh Engineers & Consultants
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .