Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | ₹16.6 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹18.4 L+₹1.8 L (10.8%)Rejected-Finance | ₹18.4 L+₹1.8 L (10.8%) | L2 | Rejected-Finance L2 |
Tender Value
₹18.7 L
EMD Value
₹37,460
Closing Date
17 Apr 2025, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
PROVN OF HOT/COLD ROOM AT 40 MVH UNDER ZONE-I AREA UNDER JAIPUR MIL STN.
2025_MES_701932_1
82443/JPR/E8
Open Tender
Civil Works
Item Rate
180 days
GE JAIPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE JAIPUR
₹37,460
Yes
9 Jul 2025
20 Mar 2025
19 Apr 2025
20 Mar 2025
17 Apr 2025
4 Apr 2025
20 Mar 2025 - 3 Apr 2025
Amount
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting loose /soft soil complete all as specified and directed.
Excavation in trenches ,n exc 1.5 m wide and n exc 1.5 m depth for foundation etc or for shaft ,wells manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5 m in depth and also for laying of electric cable and getting out hard / dense soil complete all as specified and directed.
M&L for Returning, filling in ,including spreading,levelling,watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
M&L for earth filling under floors including spreading,levelling watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
M&L for hardcore of broken stone or boulders, gauge not 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rolled /rammed to a true surface complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 in foundation ,fillings and mass concrete, sub base for floor complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 ( 20 mm) type B-1 under floor complete all as specified and directed.
M&L for rough finish formwork to sides of concrete foundation ,footing , bases of columns,raft and raft beams,sides and soffits of foundation and plinth beams and similar work: vertical or to better for rough finished flat suface of concrete complete all as specified and directed.
M&L for rough finish formwork to sides and soffits of floor or roof of beam , beam haunching girders, lintels ,cantilevers ,shelves including supports , overhangs etc .for rough finished flat suface of concrete complete all as specified and directed.
M&L for rough finished formwork to soffits of supended slab such as roof slabs,floor slabs ,landings and similar work: not exceeding 200 mm (horizontal or slopping) for fair finished flat surfaces of concrerte complete all as specified and directed.
M&L for rough finished formwork to sides of pillars , posts, struts, , piers, columns and stanchions for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads ,breaks in floors, windows cills,concrete railings ,openings in concrete walls ,floor and roofs n exc 20 cm wide and sides of RCC/PCC bends in walls complete all as specified and directed.
M&L for RCC M-25 (design Mix) using 20 mm stone aggregates in foundation ,including rafts ,footings,foundation beam ,plinth beams,bases for column etc .basement slabs,under reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 (design Mix) using 20 mm stone aggregates in beams, cantilevers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC M-25 (Design Mix) slab supported on walls , beams and column in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC M-25 (design Mix) column, pillars, piers, posts and struts complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia and over ,cut to length , bent to shape required ,including cranking bending spirally for hooping for wire (annealed)not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item no 18.00 above but 6 mm to 8 mm dia complete all as specified and directed.
M&L for 25 mm thick type B-0, 1:2:4 (12.5mm graded aggregate ) as in roof padding complete all as specified and directed.
M&L for properly Cleaning the surfaces to remove loose particles with wire brushes and applying three coat of fibre reinforced UV resistance elastomeric liquid water proofing & heat reflective coating with acrylic polymers and polyesteral /glass fibre with roller in both directions with a gap of 12 hrs@ 1 ltr per sqm over primer coat or as per the manufacturers instructions complete all as specified and directed.
supply only integral waterproofing compound ISI Marked complete all as specified and directed.
M&L for brick work with subclass 'B' bricks ,straight or curved on plan exc 6 m mean radius built in with 1:6 cement mortar complete all as specified and directed.
M&L for Rendering 15 mm thick cement plaster in CM 1:6 on fair face of brick work (internal surface) including finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick cement plaster in CM 1:4 on other faces on brick masonary (external surface) including finished even and fair without using extra cement complete all as specified and directed.
M&L for Rendering 5 mm thick cement plaster in CM 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands ,sunk panels ,cornices ,skirting,drip moulds and similar work n exc 15 cm in width or girth ; including cutting to edges ,allitres and stopped ends,etc complete all as specified and directed.
S&F GI tubing medium grade with all fitting 15 bore fixed to wall or concealed or fitted to ceiling or laid under floor complete all as specified and directed.
S&F ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic bal serewed for iron pipe 20 mm dia and fixed (min weight 210 gms) complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part -I capacity 1000 Ltr complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer complete all as specified and directed. (Make : For wall putty- Birla white/Bison wall putty of Berger/Narolac wall putty/Asian paint powder putty /Acro wall guard.) complete all as specified and directed.
M&L for preparing new plastered surfaces and applying three coat of white wash on Ceiling complete all as specified and directed.
M&L for preparation of newly plastered surface wall and applying two coats of cement paint of any tint over a coat of primer complete all as specified and directed.
M&L preparing new steel surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome complete all as specified and directed.
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed coloured ceramic tiles 300 x 450 x 7 mm thick , on vertical surface of wall such as dado , skirting etc set and jointed in neat cement slurry complete all as specified and directed.
M&L for 50 mm thick plain cement concrete type C-1 1:3:6 (using 20 mm graded stone aggergates ) as in plinth protection finished even and fair with joints 10 mm wide and in full depth at corners and @3 m c/c filled with mastic mortar complete all as specified and directed.
S&F powder coated any colour (minimum thickness of powder coating 50 micron) anodised aluminium frame for door /windows/ventilators with one or more rebates including joining cleat for fixing etccomplete all as specified and directed.
S&F powder coated any colour (minimum thickness of powder coating 50 micron) anodised aluminium windows/ ventilator shutters,fixed / sliding type without sash bar ,aluminium section weighing 0.55 kg/m including necessary joining cleats for fixing etc, glazing clips, rubbers packing , locks, anodised aluminium snap beading screw etc complete all as specified and directed.
M&L for 5.5 mm thick sheet glass ,ordinary quality and glazing with aluminium beads and rubber gaskit in square exc 0.5 sqm in each pane frosted on one side complete all as specified and directed.
Material and labour for Fe-290 (Gde -165) rolled mild steet Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed.
S&F Mild steel, plain, black sheet 1.60 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F framed work as in door or gate of angle or other section with gusset plates, rail, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting also fastening and fixing complete conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
S&F Stop valves 15 mm bore fancy type ,chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F Gun -metal ,globe or gate valve ,with iron wheel head ,screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
S&F GI tubing medium grade with all fitting 20 bore fixed to wall or concealed or fitted to ceiling or laid under floor complete all as specified and directed.
Cutting existing steel tubing 20 mm bore of pipes for alterations or additions (Each Cut Measured) complete all as specified and directed.
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
M&L for Vulcanized rubber stable mat for flooring (12mm-17mm thick)of 3mpa tensile strength and min 250 % elongation at break and weight 15-20 Kg/Sqm including fixing on surface complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenoic laminated white sheet cover for mounting switches, scokets, fan regulators as required for one light point controlled by one switch complete all as specified and directed.
All as per item No. 50.00 above but one fan point controlled by one switch complete all as specified and directed.
All as per item No. 50.00 above but socket outlet 6 Amps controlled by one switch on the same board with other swithces complete all as specified and directed.
All as per item No. 50.00 above but socket outlet 6 Amps controlled by one switch on independent board complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenoic laminated white sheet cover for mounting switches, sockets as required for one 16 Amps socket outlet point controlled by one switch on independent board complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amp complete all as specified and directed.
S&F switch piano flush button single pole one way 16 Amp complete all as specified and directed.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type complete all as specified and directed.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type complete all as specified and directed.
S&F humfree electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete all as specified and directed.
S&F ceiling rose 3 plates polycarbonate body complete all as specified and directed.
M&L for sub main wiring along with earth continuity conductor with, PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories 2x 6.0 Sqmm + 1x6.0 Sqmm earth wire in 20mm dia conduit complete all as specified and directed.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 200 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts,8 ways complete all as specified and directed.
S&F MCBs of 'B' curve single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
All as per item No. 63.00 above but double pole 32 to 63 Amps complete all as specified and directed.
S&F LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 115 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed.
Supply and fixing in repair building LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, clamp bracket 1.2 mtr long medium grade 32 mm GI pipe with nut bolt and clamp suitable size with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic with blades, down rods, electronic 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply, install, commissioning and testing of hi wall split Air Condition units in Stone walls - Type: Split AC, Inverter Model, 5 Star Rating, adhering to Specified BEE & EER above 3.1, Refrigerant R 410 A Environmental Friendly Gas - indoor/outdoor complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality, Evaporator & Condenser Coils 100% Copper tubing and of capacity 2.0 TR with Voltage Stabilizer of suitable capacity, copper piping, service wire, outdoor mounting stand complete all as specified and directed. Make:- Carrier, Voltas, Hitachi as approved by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed input variation between 170 V to 250 V with output stabilized at 230 V with accuracy ± 2.5% and of capacity 5.0 KVA complete all as specified and directed. Make:- V-Guard, Voltas,Indo as approved by Engr-in-Charge.
S&F Copper Tubing suitable for the Item Nos 68.00 & 69.00 in extended lengths as required from indoor to outdoor and Suitable insulation of Nitrile Rubber insulation fixing arrangement commissioning and testing complete Note:- One meter run of suction line of size 1/2" or 3/8" and Liquid line of size 1/4" along with Nitrile rubber insulation is counted as One RM for measurement purpose complete all as specified and directed.
Cutting of Stone walls and placing of 4" dia PVC pipe of required length for split AC pipe lines, Power lines and drain pipe to pass through and making the surface good for further installation process complete all as specified and directed.
Supply and fix 20 Amp, single pole and neutral, socket outlet with 2 pole and earth, metal enclosed plug top in powder coated CRCA steel sheet enclosure recess mounted with chained metal cover for socket outlet with and including one number single pole 'B' series MCB 25 amp as required complete all as specified and directed.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour 25 mm dia along with accessories of nominal sizes 2x6 sqmm + 1x6 sqmm earth continuity conductor complete all as specified and directed.
S&F MCB distribution board ETPN 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed.
S&F MCBs as per load requirement 'B' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) Single pole 06 to 32 amp.
(b) Four pole 63 amp.
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor 1100 V grade nominal cross sectional area 16 Sqmm, 4 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/floors/equipment etc including jointing and testing complete all as specified and directed.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed.
Material and labour for sand cushioning to under ground electric cable all as per clause No 19.75 of MES SSR Part-I (1991) complete all as specified and directed.
Schedule of Credit
PUSHPA G ENTERPRISES (BID ID -3283540)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .