Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ok |
| 2 | Accepted-Technical | Accepted-Technical ok |
Tender Value
₹5.0 L
EMD Value
₹9,940
Closing Date
16 Sept 2026, 1:00 pmClosed
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Executive Engineer M/Garh W/S Mech. Division, Narnaul, Pin. 123001
Repair and servicing of VCB Panels/Starters Panels at Pump House MC-1 of M/Garh Canal under M/Garh W/S Mech. Division, Narnaul
2026_HRY_545970_4
4451-64/9-A Dated 03/09/2026
Open Tender
Pumps/Motors
Works
60 days
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹9,940
Yes
16 Sept 2026
7 Sept 2026
16 Sept 2026
7 Sept 2026
16 Sept 2026
7 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance of VCB's installed at various pump houses of main canal (MGC) of any type, make & capacity complete to make functional in case of any type of fault occurs at any site/pump house within prescribed time frame by providing skilled & expert mechanic/ engineer including following works involved:
(i) By Disconnecting of HT connections and DC connections from existing bus bar and disconnecting trolley including servicing of complete parts of VCB of any make any capacity , cleaning with carbon tetrachloride lubrication of mechanical parts , adjustment and calibration of complete relays etc., checking complete parts including replacement of control wiring with single core copper conductor cable of existing size as required for VCB of any type any make for satisfactory running and replacement of defective parts with new one to make it fully functional , including one coat of H- class insulation paint on bus bar spouts and other connected parts including reassembling the VCB , reconnecting all HT & AC/DC connections complete in functional order including testing on existing load complete all as specified and directed .
(ii) Only fixing in replacement of all the defective parts such as metering devices, relays, control devices, indicators, charging motors, mechanical gears/handle ,rotary switches, CT's, PT's , Bushes, control fuses, contactors, MCB's, Battery bank etc or all any leftover items as shown in separate schedule of this tender on cost basis and separate payment shall be made on approved rates after approval by competent authority with maintaining proper record in document. Note:-( i) In case of any complaint , the agency shall provide expert engineer at respective site to attend the site i.e. MC-1 of MGC for repair & rectification of defect developed in VCB's all of sudden within 24 Hours after complaint given by concerned JE/SDO. Penalty charges @ 0.5% of particular work per week shall be levied in case of not attending the complaint. (ii) The quoted rates shall include for fixing of serviceable parts in position and replacement of unserviceable parts with new parts.
(iii) The new parts shall be measured and paid separately under appropriate item schedule part-II as supply only mentioned herein after.
(iv) Small items such as nut, bolts, screws & washers required at site are deemed to be included in the quoted rates by the contractor.
(v) The complete work (repairing, servicing &calibrating) shall be carried out by authorised skilled engineer of the approved agency. | 9 | Each Job | - | - |
| 2 | Servicing & Repair of existing LT Panels/ Starter Panel of Various Makes and of different capacity in amps. with all accessories installed at various Pump Houses under W.S Mech. Division, Narnaul which includes following Activities : -
A. Servicing and Repair of ACB/MCCB/Contactors
1. Removal of Dust and Foreign Matter, carbon deposit from Panel Box with a vacuum cleaner/Air Blower and Wiping with a clean, dry cloth and cleaning agent.
2. Applying layer of Grease and Oiling of all Mechanical Parts and main contacts of for Smooth operation.
3. Checking of All the Connections and tightening them as per standard practice.
B. Replacement of defective control wiring with suitable size PVC copper wire (if any)
C. Replacement of defective Indicating Lamps and Push Buttons.
D. Replacement of Locking System of Panel.
E. Measurement of Insulation Resistance b/w Main conductor (R, Y, B) and Ground with 1000V Meggar.
Note:-
(i) Only fixing in replacement of all the defective parts such as metering devices, relays, control devices, indicators, charging motors, mechanical gears/handle, rotary switches, bushes, control fuses, contactors, MCB's, etc or all any leftover items as shown in separate schedule of this tender on cost basis and separate payment shall be made on approved rates after approval by competent authority with maintaining proper record in document.
(ii) The new parts shall be measured and paid separately under appropriate item schedule part-II as supply only mentioned herein after.
(iii) Small items such as nut, bolts, screws & washers required at site are deemed to be included in the quoted rates by the contractor. | 3 | Each Job | - | - |
| 3 | Supply & Erection of copper fingers/contacts R, Y, B as per approved make | 6 | Set. | - | - |
| 4 | Supply only spring charging gear assembly for VCB 3.3 KV as per existing complete of approved make. | 2 | No. | - | - |
| 5 | Supply & fixing of Vacuum Interrupter (bottle) Model WL-34599 M3 complete for VCB 3.3 KV as per existing VCB complete of approved make and as per sample | 6 | No. | - | - |
| 6 | Providing, Erection & Testing of master trip Relay for VCB panel as per approved make. | 2 | No. | - | - |
| 7 | Supply & fixing of Ampere meter Digital type 96x96 mm, 0-200 Amps complete for VCB 3.3 KV as per existing complete of approved make | 5 | No. | - | - |
| 8 | Supply & fixing of Volt meter Digital type 96x96 mm, 0-12 KV complete for VCB 3.3 KV as per existing complete of approved make | 5 | No. | - | - |
| 9 | Credit of old Iron scrap (Actual weight of old scrap will be measured by the committee)
Old scrap/parts shall be property of firm. | 20 | Kg. | - | - |
| 10 | Credit of old Copper scrap (Actual weight of old scrap will be measured by the committee)
Old scrap/parts shall be property of firm. | 2 | Kg. | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_625567.xls
BOQ • 0.28 MB
bidbook4.pdf
Additional Documents • 4.35 MB
AnnexuresC.pdf
Other Document • 0.54 MB
CORRIGENDUM.pdf
PDF • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .