Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹32.5 L
EMD Value
₹32,467
Closing Date
4 Feb 2026, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer (Agril.), NZ, Sambalpur
Superintending Engineer (Agril.), NZ, Sambalpur, At/Po-Remed, Dist-Sambalpur, Pin-768006
Development and beautification of CDAO campus Deogarh including a design of External facade, Boundary wall, main gate, land scaping etc.
2026_AGRIL_124992_2
06/Agril. / NZ / 2025-26
National Competitive Bid
Civil Works - Others
Percentage
120 days
Deogarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
Superintending Engineer (Agril.), NZ, Sambalpur
₹32,467
Yes
27 Jan 2026
27 Jan 2026
9 Feb 2026
27 Jan 2026
4 Feb 2026
27 Jan 2026
Part-A (MCM Cladding, Raising of Boundry wall & Structural Glazing & Upvc Windows)
Removing old lime or cement plaster from walls/Ceilings including raking out joints 12 mm deep and removing the debris within 50m lead etc. complete. as per direction of Engg.-in.charge.
Ground Floor
16mm. thick cement plaster in c.m. 1:6 over brick masonry including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge .
Ground Floor
First Floor (outside)
Wall Priming one coats on new work with wall water bound primer of approved shade as per direction of Engg-in-Charge .
Ground Floor
First Floor (outside)
Wall painting two coats with Plastic emulsion paint of approved shade as per direction of Engg-in-Charge .
Ground Floor
Wall painting two coats on new work with Weather coat paint of approved shade as per direction of Engg-in-Charge .
Ground Floor
First Floor (outside)
Enamel Painting two coats with enamel paint of approved quality etc. complete as per direction of Engg-in-Charge .
Ground Floor
First Floor (outside)
Supply and fixing of MCM Modified Clay Material - MCM A Series Brick - 240 x 60 mm of PHOMI make, as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.
Supply and fixing of MCM Modified Clay Material - MCM R Series Brick (087089) - 222 x 63 mm of PHOMI make, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.
Brick work with Fly Ash Bricks having crushing strength 75 kg/sq.cm in c.m. 1:6 in F & P including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge .
Brick work with Fly Ash .Bricks having crushing strength between 100kg/sq.cm to 149kg/sq.cm in c.m. 1:6 in Sup.Str. including cost conveyance and royality of materials curing etc. complete as per direction of Engg-in-Charge .
Ground Floor
First Floor
Second Floor
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing system. Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test”Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” as per direction of engg-in-charge.
All Floors
Supply fitting and fixing MS grill with Iron work wrought and put up in grated doors, windows and cage latrines etc. complete as per direction of Engg-in-Charge .
Supplying , fitting and fixing of two Track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame. shutters and all fitting and fixtures etc. complete as per direction of Engg-in-Charge .
All floor
Part-B (Main Gate with Cow Catcher & Drainage System)
Excavation of founation in laterite rock or any hard rock (other than granite or disintigrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department etc. complete as per direction of Engg-in-Charge .
Filling foundation and plinth with sand and well watered and rammed including cost, conveyance and royalty etc complete as per direction of Engg.-in-Charge.
Cement concrete (1:3:6)with 40mm size CBHG metal including cost, conveyance and royalty etc. complete as per direction of Engg.-in-Charge.
Cement Concrete (1:2:4) with 12 mm size broken hard granite chips for R.C.C. works including hoisting and laying etc. complete as per direction of Engg-in-Charge .
Providing and Laying reinforcement Cement concrete (M-20) with 20 mm and down graded chips including cost all materials,labours,T & P,curing etc complete (excluding the cost of reinforcement & Centering, shuttering) as per direction of Engineer-in-charge.
Column Base
Beam & Column
Ground Floor
Roof Slab
Ground Floor
Lintel bend( over existing boundry wall)
Ground Floor
Supplying, fitting and placing uncoated HYSD bar reinforcement complete in proper position including cost of binding wire 18 to 20 gauge as per direction of Engg.-in-Charge.
Ground Floor
6mm.thick cement plaster with C.M(1:4) to RCC surface including closed deep chipping and slury treatment etc. complete as per direction of Engg.-in-Charge.
Ground Floor
Supply and fixing of MCM Modified Clay Material - MCM A Series Brick - 240 x 60 mm of PHOMI make, as per company standard dimension, pattern, colour as specified, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K — EN 12667 (2001), thermal resistance of 0.0568 M2 K/W— EN 12667 (2001) and Fire Insulation - Class A— ASTM E84- 15. The product should be patented from United States and Europe and with certifications by IGBC, Singapore Green Label and China Green Building material. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and substrate and per directions of Engineer in-charge. Grouting should be done using filling and pointing method as per installation drawing provided, and colour of the grout should be as per the architect’s specification depending on the substrate and as per the direction of Engineer in-charge.
All Floors
Supply fitting and fixing MS grill with Iron work wrought and put up in grated doors, windows and cage latrines etc. complete as per direction of Engg-in-Charge .
Ground
Eamel Painting two coats with enamel paint over one coat of primer of approved quality etc. complete as per direction of Engg-in-Charge .
Ground Floor
Supplying , fitting and fixing of 125mm MS pipe for caw catcher etc. complete as per direction of Engg-in-Charge .
Iron work wrought and put up in trusses and record racks including all labour and Materials etc, as per direction of Engineer -in -charge. (covering of RCC Drain)
PART(C)-Construction of Paver Block and street light
Filling foundation and plinth with sand and well watered and rammed including cost, conveyance and royalty etc complete as per direction of Engg.-in-Charge.
Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018. As per S/R 2022 Page No.-233 sl No.25.17.1
Supply and fixing 18W Integrated solar street / Garden light suitable for perfect solar system solution for remote & off grid locations. Housing in aluminium alloy body which makes it water & rust proof with IP65.Enclosed inside the unit multi cell LEP Technology BATTERY Lithium Ion/Oxide 24Ah+1%,12.8V+0.4V,Max continuous discharge current (w/o PCM)upto42A,should conform to the latest BIS/International standards which is charged by a highly effiecient mono-crystalline solar panel.The LED Iuminary delivers close to 120 lumens per watt and is made from the finest LEDs from Bridgelux/Oshram/Philips confirmed to BIS specification.The light must have dust to drawn system to auto control the device.The Streetlight is a plug & play unit and can be very easily mounted on walls or poles via the extensions provided with the product itself.A manual ON/OFF switch has also been provided so that the light can be awitched off when not in use for a long time etc. complete as per direction of Engg-in-Charge .
Fixing industrial Chequred tiles in floors,treads or steps and landings on 25 mm thick CM (1:1) jointed with neat cement slurry mixed with pigments to match the shades includind cost for rubbing, polishing & cost of marbel tiles etc. complete as per direction of Engg-in-Charge .
Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead etc. complete. as per direction of Engg.-in.charge.
Dismantling and removing old tiled flooring including removing the base coarse and stacking the useful materials for reuse and removing the debris within 50m lead etc. complete. as per direction of Engg.-in.charge.
Part(D) - Land scaping & Gardening with Six Month maintainance including water supply
Earth work by mechanical means borrowed from out side/from site within 5km initial lead and 1.5m initial lift including levelling and dressing the bed and sides depositing muck within initial lead and lift etc. complete as per direction of Engg-in-Charge .
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : etc. complete as per direction of Engg-in-Charge . (CPWD -DSR Horticulture & Landscaping -2020, Page No.-224, sub Haed-2.40)
Screened through sieve of IS desination 20 mm
Screened through sieve of IS desination 16 mm
Screened through sieve of IS desination 4.75 mm
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation etc. complete as per direction of Engg-in-Charge . (CPWD -DSR Horticulture & Landscaping -2020, Page No.-227, sub Haed-2.60).
Spreading of sludge, dump manure and/or good earth in required thickness (cost of sludge, dump manure and/ or good earth to be paid separately). etc. complete as per direction of Engg-in-Charge . (CPWD -DSR Horticulture & Landscaping -2020, Page No.-228, sub Haed-2.80)
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge . (CPWD -DSR Horticulture & Landscaping -2020, Page No.-228, sub Haed-2.90)
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. (CPWD -DSR Horticulture & Landscaping -2020, Page No.-238, sub Haed-2.28)
Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge. (CPWD -DSR Horticulture & Landscaping -2020, Page No.-246, sub Haed-2.33)
PART-II (Foliage / Shade Loving Plants)
Providing and displaying of Araucaria cookie plant, having ht. 60 cm to 75 cm, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 20 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge (CPWD -DSR Horticulture & Landscaping -2020, Page No.-278, sub Haed-3.13)
Providing and displaying of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge (CPWD -DSR Horticulture & Landscaping -2020, Page No.-280, sub Haed-3.18)
Providing and displaying of Rhapis palm specimen plant, having ht. 1.50 m to 1.65 m with 40 to 50 lush green suckers, well developed, fresh & healthy foliage leaves in 40 cm size of Earthen Pot/Chali/Tray & as per direction of the officer-in-charge. (CPWD -DSR Horticulture & Landscaping -2020, Page No.-296, sub Haed-3.78)
Providing and displaying of Rhapis palm specimen plant, having ht. 1.50 m to 1.65 m with 40 to 50 lush green suckers, well developed, fresh & healthy foliage leaves in 40 cm size of Earthen Pot/Chali/Tray & as per direction of the officer-in-charge.Providing and Displaying Asiatic lilly hybrid variety (3 in one) plants in each pot having in full bloom 3 to 5 flowers 30 to 45 cm ht. well developed in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge (CPWD -DSR Horticulture & Landscaping -2020, Page No.-304, sub Haed-4.60)
PART-III (Ornamental Plants)
Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge. (CPWD -DSR Horticulture & Landscaping -2020, Page No.-336, sub Haed-5.30)
PART-IV (Garden Maintainance)
Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs,herbs, edge, flower beds, foliages, creepers etc. including hoeing pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by officer-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide, lawn mover and brush cutter with fuel & other T & P material/articles shall be provided by the department.) as per direction of officer incharge. (CPWD -DSR Horticulture & Landscaping -2020, Page No.-249, sub Haed-2.39)
Permanent Office Accommodation for 12 month
Removal of garden waste by TATA 407 or equivalent including loading/unloading and carriage upto 1 km lead,complete disposal upto designated place as per direction of officer-in-charge (CPWD -DSR Horticulture & Landscaping -2020, Page No.-260, sub Haed-2.60)
Providing, fitting and fixing of automatic sprinkler with all fittings(Includes- Main, Submain, Lateral, Headunit and sprinkler set) for workable condition and tested as per direction of the officer-in-charge
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge
25mm pipe
20mm pipe
Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per Engg.-in- charge. 250mm wall
All Floor for rain water
Cutting holes in R.C.C floors and roos upto 19cm thick for passing G.I/P.V.C pipes and fitting etc. and prepairing the holes after insertion of pipe etc. with cement concrete 1:2:4 including finishing complete so as to make it leak proof as per Engg.-in- charge.
All Floor for rain water
Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification etc complete as per Engg.-in- charge.
All Floor for rain water
Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes complete as per direction of Engineer-in-Charge
75mm OD P.V.C. SWR S/S Pipe (ISI type-A)
All Floor for rain water
90mm OD P.V.C. SWR S/S Pipe (ISI type-A)(for rain water)
All Floor for rain water
110mm OD P.V.C. SWR S/S Pipe (ISI type-A)
All Floor for rain water
Laying in trenches unplasticised PVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by heat application method including testing as per specification complete. (Earth work in trenches to be measured and paid for separately)
125mm dia rigid UPVC pipe Class -3 (0.60Mpa)
All Floor
Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansios etc complete as per direction of Engineer-in-Charge
PVC SWR coupler
75 mm dia PVC SWR coupler
All Floor
90 mm dia PVC SWR coupler
All Floor
110 mm dia PVC SWR coupler
All Floor
Single tee with door
75 x 75 x 75mm dia PVC SWR Tee
All Floor
90 x 90 x 90mm dia PVC SWR Tee
All Floor
110 x 110 x 110mm dia PVC SWR Tee
All Floor
SWR Plain Bend 87.5°
75mm diaP.V.C. SWR plain bend 87.5
All Floor
90mm diaP.V.C. SWR plain bend 87.5
All Floor
110mm diaP.V.C. SWR plain bend 87.5
All Floor
SWR Plain Door Bend 87.5°
75mm diaP.V.C. SWR plain bend 87.5
All Floor
90mm diaP.V.C. SWR plain bend 87.5
All Floor
110mm diaP.V.C. SWR plain bend 87.5
All Floor
Supply , fitting and fixing of following fixers including all materials and labours etc all complete as per specification complete as per direction of Engg. in charge.
450x450mm Square Man Hole Cover -16.0 kg
90mm dia P.V.C. Nahani Trap
110mm dia PVC SWR Single Y with door
PVC SWR Jalli 110mm dia
110 mm dia P.V.C. SWR Vent Cowl
UPVC BALL VALVE Sch-80 (Solvent Welded with Metal Ball)
25mmdia
S/F of Garden/ Lawn/Boubdry wall light fitting with LED SOLAR LIGHT/BOLLARD type etc. complete
Providing, fitting and fixing of LED Sign Board as per direction of the officer-in-charge. Specification MS Structure foe Back Side of Sign Board (using 2inXlin Rectangle Pipe 16 gauge), A) 3mm ACP Sheet B) ACP Sheet With Letters With LED Lights C) Acrylic Sheet Mounting from Back Side D) PVC Boxes for LED Letters Mounting E) Samsung LED Madulers F) Waterproof Adapter
PART-E (furnishing of CDAO office chamber etc.)
Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front modular cover of suitable size , MS modular box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard )
Group-A
Group-B
Group-C
Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor o f ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)
all floors
Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)
all floors
Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard)
all floors
Supply and fixing of 3 no.sof 3pin 5/6 amp modular socket and S.P. 5/6 amp one way modular switch, 1 no. of 5 pin 15/16 socket out let and S.P. 15/16 A one way modular switch on Modular G.I. Box with Modular Base and cover etc complete(Make of wire Finolex/L&T/Anchor/Havels/V Guard)
all floors
Supply and fixing of 3 pin 6Amp plug with 6Amp switch on existing board (Modular type ).(Make of wire Finolex/L&T/Anchor/Havels/V Guard)
all floors
Supply and fixing of following way single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic covr for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB / RCCB / Isolator) - 4Way double door
all floors
Supply and fixing of 5Amp to 32A rating 240V "B/C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. as required.(make-HPL/ Havells/ Legrand /L&T/C&S)
all floors
S/F of 1x18 Watt LED T-5 fitting(Make-Crompton/Philips/Havells/Bajaj)
all floors
MV cable laying up to 10 sq.mm 2core on surface Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 20 sq.mm on surface as required.
S/F of 18 Watt LED Square surface mount fitting (Make-Havells/Philips/C&S/Crompton) as requred.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm - 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I)(No deduction have to made for light opening.)etc. complete as per direction of Engg-in-Charge .
Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete. SR-2022, page No.-234, sl no,-5
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.30 MB
DTCN_1.pdf
Tender Documents • 1.96 MB
BOQ_577481.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .