| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹43.5 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹45.9 LRejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | Rejected-Technical H NO 502 B BLDG WELWORTH PARADISE PANCARD CLUB ROAD OPP MARBEL SOCIETY NEAR DHANKUDE VASTI BANER PUNE MH 411045 | PUNE | PUNE | MAHARASHTRA | 411045 | - | Rejected-Technical DUE TO NO IN WORK LOAD RETURN |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
ADDN/ALTN/IMPROVEMENT TO GUARD REST ROOM, MTR AND S AND MT SECTION AT 26ED AND PROVN OF SECURITY LIGHTS AT ASTE UNDER GE (AF) MARATHAHALLI BANGALORE
2025_MES_699347_1
8753/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹98,000
Yes
19 Jun 2025
25 Feb 2025
1 Apr 2025
25 Feb 2025
28 Mar 2025
13 Mar 2025
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc. 15cm thickness (below or above ground).
M&L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in floor complete all as specified and directed.
M&L for hard core of broken stone gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick each, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in plinth protection,path ways etc. finishing surface even and fair including. making of groove as specified and directed.
Dismatling floor, hearth or wall tilling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises
M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc. 0.06sqm and n.exc. o.11 sqm in floor set and jointed in cement clurry and pointed with coloured cement to match with coloured tiles over and including cement screed or bedding layer of cement mortar 15mm thick in 1:6. complete all as specified and directed.Make- SOMANY/ KAJARIA/JOHNSON/ AGL
M&L for non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc. 0.18sqm and n.exc. 0.38 sqm. floor set and jointed in cement clurry and pointed with coloured cement to match with coloured tiles over and including cement screed or bedding layer of cement mortar 15mm thick in 1:6 complete all as specified and directed.Make- SOMANY/ KAJARIA/JOHNSON/ AGL
M&L for glazed ceramic coloured wall tiles of 350X 250X7mm/450X350X7mm as in dados, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and above 10mm thick cement plaster in 1:4 as backing coat complete all as specified and directed.Make- SOMANY/ KAJARIA/JOHNSON/ AGL
Demolition of brickwork or stone/ boulder masonry, built in cement mortar , incl all quions, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width (Type C-1) 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:6, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L for rendering 15mm thick in cement mortar 1:6 on brick and concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15mm thick in cement mortar 1:4 on brick and concrete surfaces in two coats (10mm thick setting coat and 5mm thick with WPC) as specified, finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar 1:3 on brick and concrete surfaces of ceiling, finished even and smooth without using extra cement including. WPC complete all as specified and directed.
Disconnecting exisiting PVC water tanks of 500 liters to 1000 liters capacity setting aside or lowering for carrying out roof repairs etc, including cleaning and removal of all scale, dirt etc from tanks and from mouths of circulating pipes, hoisting the tanks reconnecting and refixing in position, all as specified and as directed
Taking up or down 20mm bore steel tubing and connection including cleaning and refixing complete with new fittings all as specified and as directed
Taking up or down 25mm bore steel tubing and connection including cleaning and refixing complete withall fittings all as specified and as directed
M&L for Rendering 10mm thick on fair face of concrete surfaces in cement mortar 1:3 with WPC as specified finishing even and smooth with out using extre cement complete all as specified and directed.
Supply only integral water proofing compound all as specified
Providing and applying HS TPO membrane of 1.2mm thick with a layer of 200gsm Geo-Textile with overlap joints of 75 mm in both longitudinal and transverse direction of the TPO and sealed properly with hot air welding and terminate TPO at the top of parapet wall with terminatin strip and fix it by screw at 300 mm c/c and sealed with HS Joint seal PU on top including surface preparation like remove all loose gravels,dirt,oil,grease,and other foreign particles by jet or dry air and clean the surface mechanically or by grinding to make it smooth before application and PCC / cementitious coving of 75 mm radius shall be provided at all junctions between vertical and horizontal faces before application of TPO completely as per specification and direction. Note:- work to be carried out by authorized applicator of M/S Berger or equivalent in ASIAN/FORSOC/Dr. FIXIT/ IXL/ TIKKI)
Taking up or down GI tubing 20 mm bore from trenches/wall including all fittings segregated and stacking the pipe complete all as specified and directed.
Description all as per item No 21 above but 25 mm dia bore
S&F of 20 mm dia(OD) CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting fixed complete to walls, ceiling or laid in floors etc including short length , with all pipe fittings such as ends, elbow, unions, tee, reducing tees etc. including taking down all as specified and directed
S&F of 25 mm dia(OD) CPVC pipes SDR 11 & Plain CPVC SDR 11 fitting fixed complete to walls, ceiling or laid in floors etc including short length , with all pipe fittings such as ends, elbow, unions, tee, reducing tees etc. including taking down all as specified and directed
S&F for Rotational moulded polyethylene water storage tank of 500 ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position including taking down the old tank all as specified and as directed.
-ditto- but 1000 ltrs capacity .
S&F in repair Chromium plated fancy type bib taps with wall flange, cast copper alloy with round operating knob screwed down high pressure, screwed for 15mm bore iron pipe complete all as specified and directed.
S&F in repair 15mm bore pillar taps fancy type cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair stop valves/angle cocks or two way angle cock cast copper alloy concealed type long body with round operating knob chromium plated screwed down high pressure, screwed both ends for 15 mm bore iron pipe or brass ferrule.
M&L for Concussive push button CP taps of15mm dia cast copper alloy,screwed for iron pipe and fixed
S&F in repair 20 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and complete all as specified and directed.
S&F in repair 25 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and complete all as specified and directed.
S&F in repair 25 mm bore ball valves, high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210gms) complete all as specified and directed.
S&F in repair CP waste coupling of 32 mm dia (half or full thread) including taking down old coupling of any description complete all as specified and directed.
S&F CP grating 100mm size made out of stainless steel complete all as specified and directed.
S&F in repair PVC connection pipe 15mm dia and 600 mm long with two PTMT nuts at each ends with rubber washer
S&F in repair PVC EWC anti microbial seat cover hygenic type for padestral pattern including all fitting complete all as specified and directed.
S&F in repair soap dish (Any Type) fixed to wall with brass chromium plated screws complete all as specified and directed.
S&F in repairs chromium plated shower rose with swivel joints including fixing to GI pipe for 125mm dia complete all as specified and directed.
S&F in repairs for PVC low level flushing cistern, white, 10 Ltrs capacity complete with all internal accessories & fixed to wall & making good to wall surfaces incl. taking down existing flushing cistern complete.
S&F in repair of CP Health faucet (hand shower) complete set with 1.5 mtr long pipe abd fittings complete all as specified and as directed.
PVC waste pipe, 32 mm dia, 750mm long, suitable for Kitchen sink/WHB,fixed in repairs all as specified and as directed.
S&F in repairs Vitreous China wash down water colset (Squat pattern) white complete as fixed in repair excluding flushing cistern and flush pipe "Orissa" pattern size 580x400 with integral footrest inject connection to trap antisyphonage etc complete including joint between flushing pipe and socket of WC complete all as specified and directed.
S&F in repairs Vitreous China wash down water closet (EWC) (Anglo Indian type (pedestal pattern)white complete as fixed in repairexcluding flushing cistern and flush pipe and trap white including fixing bolts,WC seat cover of fixed with aluminium or ms chromium plated complete all as specified.
S&F in repairs Vitreous China wash hand basin, angle back 550 x 400mm white excluding taps, waste chains and plugs and porcilain stopper but including bracket
S&F for Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white minimum),with grating and union for discharge pipe (excluding flushing cistern, flush pipe)
S&F in repair glass shelf(450x150mm) with chromium plated guard complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall complete all as specified and directed
S&F in repairs 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall complete all as specified and directed
S&F in repairs 110 mm dia PVC (SWR) bends of any radius with access door complete all as specified and directed
S&F in repairs 75 mm dia PVC (SWR) bends of any radius with duck foot or heel rest fitted with oval access door complete all as specified and directed.
S&F in repair 20 mm dia D type CP towel rail 600 mm long between flanges complete all as specified and directed.
Taking down chowkhats or frames with shutters n. exc. exceeding 1.5 Sq.m Each (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkhats or frames with shutters exceeding 1.5 Sq.m and not exc. 4 Sq. m Each (without taking off shutters from the frames) complete all as specified and as directed.
Supply and fixing Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube in openings all as specified .
Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site all specified and as directed.
Supply and fixing 100 mm long butt hinges, extruded aluminiun alloy with galvanised mild steel himges, anodised and fixed.
Supply and fixing 150 mm long aluminium, anodized barrel tower bolts of extruded section all as specified
Supply and fixing 150mm long extruded alluminium alloy handle, cast type, anodized all as specified
Supply and fixing 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified
S&F Anodised Aluminium powder coated Ventilators with frames section weighing not less than 0.980kg/m suitable for top portion with fixed wire mesh and louvers with glazing, bottom portion with fixed glass (Pinhead glass) incl jointing cleat for fixing glass, wire mesh etc incl necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap-beadings, screws, anodised aluminium fittings such as handles stainless steel adjustable friction stay hinges etc as required complete all as directed by Engineer-in-Charge. NOTE:- However unit rate includes cost of rubber beading, fitting such as handle, SS friction stay hinges and fixing of glass/SS wire mesh etc.complete all as specified and directed.
S&F Aluminium powder coated grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standared section and fixed to the existing window frame with CP brass /stainless steel screws @ 200mm c/c, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all comnplete as per requirement and direction .
S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane
Supply only 3.00 mm thick figured glass pin head type obscured or frosted on one side and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed
Supply only Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
DIismantling of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar.
M&L for 18 to 20 mm thick 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and mirror polishing to give high gloss finish complete.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
M&L for Heavy duty coloured Chequered cement concrete tiles 30cm x30cm x 25 to 30mm thick,laquered finish type set, jointed and pointed in neat cement slurry with gray cement pigment cement ang pigments. in floors ® Incl. 20mm thick screed bed or bedding layer in CM 1:4 complete all as specified & directed
M & L for preparating surfaces plastered or unplastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified & directed
M & L for preparating surfaces plastered or unplastered surfaces of ceiling and applying two coat of oil bound distemper over a coat of primer complete all as specified & directed
M & L for preparating surfaces plastered or unplastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified & directed
M & L for excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, poles, cables etc. n exc 10 sq m on plan and getting out in hard/dense soil.
M&L for cement concrete 1:4:8 type D-2 (40 mm graded crushed stone aggregate) as in foundation of poles, filing in mass concrete all as specified and as directed.
M&L for RCC (type B-1) 1:2:4 using 20mm graded crushed stone aggregate as in Columns/Pedestal , pillars, piers, posts and struts all as specified and as directed.
S&F TMT steel bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking end and binding with and including MS wire annealed not less than 0.9 mm dia complete all as specified & directed
All as item no 78 here in before but 6mm to 8mm dia asd in stirrups.
M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified (Flat).
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates (Fe 410-w (Gde-E-250) quality-A complete all as specified & directed
S&F for Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) includingdistance pieces, cleats etc. ® conform to Fe-410-w Grade E-250 quality A. complete all as specified & directed
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. Make- TATA/ JSW/ ESSAR
M & L for 100 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in sub base all as specified and as directed.
M&L PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in flooring 100mm thick finished even and rough without using extra cement including spiki rolling to surface or making impressions of expanded metal whilest the concrete is green iall as specified and as directed.
M & L for two coats of synthetic enamel paint for over a coat of zinc oxide incl preparation of new steel surfaces not otherwise described, over 10cm width or girth complete all as specified & directed .
M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm each as in Soft/loose soil complete all as specified & directed
M & L for Removing excavated Soil to a distance exc. 1.50km but n exc. 5km and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels, drains etc. complete all as specified & directed
Extra for forming fair finished drain or channel up to 55 cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stopped ends etc.
M & L for framed work such as grill, gratings, etc with ends of bars shoulderedand /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work corn-conforming to Fe.290. Gde -E-165, complete all as specified and directed.
M & L Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified.
Removing building materials etc. to a distance of 10 km to out side of MD Land and depositing.
Taking down carefully copper/aluminum sub main wiring of any size including casing and caping / conduit and making good the disturbed surface of walls as directed.
Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators complete all as specified and directed.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, multi stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point /Fan point controlled by one switch.
All as per item No 97 above but One 5 Amps socket point on independent board.
All as per item No.97 above but wiring complete with 2.5 Sqmm with 2.5 sqmm as earth wire for 3 pin 15A socket multipurpose on independent board .
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
S & F modular socket 06 Amps 2/3 pin, 2 module complete all as specified & directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified & directed. Make- HAVELLS/ BAJAJ / PHILIPS
S & F modular socket 06/16 Amps 2/3 pin 2 module complete all as specified & directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified & directed. Make- HAVELLS/ BAJAJ/ PHILIPS
S & F MCB SPN 32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB DB SPN 8 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
Supply and fixing LED light fittings 1x22 watts,220V ,AC decorative box type with driver,holder including LED tube light connecting up with three core flexiable copper conductor cable of suitable size from ceiling rose complete with all accessories complete all as specified & directed by Engineer In charge.Make-BAJAJ/HAVELLS/WIPRO/ PHILIPS
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer In charge.Make-BAJAJ/HAVELLS/WIPRO/ PHILIPS
S & F electronic fan regulator modular type, 2 module, 120W including complete all as specified and directed.
M&L ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body all as specified
Taking down old GI earth wire and Supply & fixing GI earth wire 4.00 mm dia for interconnecting of earth electrodes all as specified.
M&L earthing and Supply and fixing in repair/ replacement of Earthing to DB panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified & directed. Make- Polycab/ Finolex/Havells/ Gloster/ RPG
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
S & F MCB DB SPN 4 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
Supply and fixing LED PC battern light fitting of 4 feet 20 watt,with energy efficient LED and integrated electronic driver of 20 W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and as directed .Make-BAJAJ/HAVELLS/WIPRO/ PHILIPS
M & L for sub main wiring complete with two runs of 2.5 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Make- Polycab/ Finolex/Havells/ Gloster/ RPG
M&L ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body all as specified
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.Make-BAJAJ/HAVELLS/WIPRO/ PHILIPS
Taking down in replacement andSupply, fix, test and commssioning of GI Steel tubing medium grade 50 mm dia/bore along with fittings in trenches/wall complete all as specified and directed Make :- Jindal/Tata/Zenith/BST/Advance Steel Tubes
Taking down in replacement and Supply, fix, test and commssioning of GI Steel tubing medium grade 25 mm dia/bore along with fittings in trenches/wall complete all as specified and directed Make :- Jindal/Tata/Zenith/BST/Advance Steel Tubes
Taking down in replacement and Disconnection and removing the Unserviceable gate valve 15mm dia/bore and S & F Gun metal globe or gate valve 50 mm dia/bore with iron wheel head, screwed both ends for GI Pipe complete all as specified and directed.
Taking down in replacement and and Disconnection and removing the unserviceable gate valve 15mm dia/bore and S & F Gun metal globe or gate valve 25 mm dia/bore with iron wheel head, screwed both ends for GI Pipe complete all as specified and directed.
Supply and fix steel tubular swaged poles Type 410SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, Including foundation and coping complete all as specified and directed.Make- India Tubes/ Bombay Tubes/Kalinga Tubes/Singh Profile, Pune/National Tubing ,Kanpur
Supply and fixing pole mounted junction box/bus bar chamber for loop connection of street light cable of size 295x195x100 mm with 63 amps aluminium busbar wrapped with PVC sleeves and maintained the colour code and provision of making holes with GI nuts, bolts & washers for connections and mounted on hydrograpic insulators with nuts & bolts at both ends of busbar and suitable arrangement for fixing one no MCB complete all as specified and as directed. Make: Sintex / Hansel
S&F MCB, Single pole, 6 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed (Make : Legrand/ Hager/ABB/Siemens).
Supply and fixing of 70 W LED Street Light fitting pressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
Supply and fixing of Nature switch (using infrared sensor technology )based automatic street light control panel .This panel should be suitable enough to 3 phase load of 5 KW .Nature switch operation should be based on natural light lux level .Required illuminance level for switching ON is < 60 Lux & for switching off > 10 lux .The sensor alongwith suitable power contactors and incoming outgoing MCB should be enclosed in a pole /wall mounted rust proof ,electric shock ,termite proof and FR grade SMC Enclosure conforming to IP 54 ,The circuit should also have aprovision for manual operation (i.e sensor bypass option ) .The nature switch must have 3 phase load of 5 KW (swadeep 02EC-5kW3p with 3 nos incoming outgoing MCBs of 16 -20 Amps & 3 nos contactors (single pole /2/ pole/3 pole ) of 16-20 Amps & circuit wiring (copper )10 mm2 complete all as specified and as directecd :Make : Swadeep
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.Make- Polycab/ Finolex/Havells/ Gloster/ RPG
Excavating in trenches exceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 m in depth for laying of cables & foundation of poles, stay assembly and getting out in soft loose soil complete all as specified and directed .
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of the LT poles including form work complete all as specified
M & L for G.I. tubing light grade of size 40mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure.
Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
Supply and fixing in repair of Earthing to pole with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2020, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron
Supply and fix energy saving Envirmental friendly long life exclusive innovative die cast aluminium LED Flood light 100W IP 65 with high power complete all as specified and as directed.Make : Havells/ BAJAJ/ PHILIPS/ WIPRO
Supply and fix energy saving, envioronmental friendly long life exclusive innovative die cast aluminium LED street light 45 watt IP 66, 230 Volts complete all as specified and as directed. Make : Havells/ BAJAJ/ PHILIPS/ WIPRO
M & L for street light fitting made upto 50 mm GI tubing medium grade upto 1.5mtr long including bending,welding ,drilling holes as required and fixing with flat MS clamps 25x5mm thick (02nos) with suitable nut,bolts and washers to steel tubular/concrete poles/wall complete all as specified and as directed.
B5BUILDING SOLUTIONS (BID ID -3272841)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .