Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | Admitted-Finance |
| 4 | Admitted-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Repair Maint of HT LT OH Line including detection of cable fault in the area of Signal Enclave APS Colony KV No II Sanjay Vihar 1 CBPO USI AWWA 5 Signal Gp Asmera Line IDSA NOM Varuna AAKANSHA in the area of AGE U Elect Supply No III under G
2020_MES_356042_1
GE ELECT/D-45/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹60,000
Yes
4 Sept 2020
31 Jul 2020
29 Aug 2020
1 Aug 2020
27 Aug 2020
22 Aug 2020
60 days
Amount
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 01 above but 1100 Volt LT cables
M&L for repair and rewinding of three phase high mast tower motor 440 volts AC 1 HP 1425 RPM including dismantling from high mask, transportation to wksp for repair, rewinding of motor with existing size of super enamle copper wire, replacing of gear, bearing,bush greasing warneshing etc, replacement of wire rope dog clamp for running of wire rope at satisfactory level and re-installation complete all as specified and directed.
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by engineer –in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge
S&Laying in replacement sub class B bricks having minimum compressive strenth 75 Kg/sqm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per Srl item No 8 here in before but using old bricks obtain under item No 1.
Supply and lay in replacement unreinforced precast concrete cable covers class HV Type -1 with peak size 300 x 180 x 40 mm. compete all as specified and directed
All as per srl item No 10 here-in-before but using old tiles obtained under srl item No 1.
Supply, Laying, connecting, testing and commissioning in replacement ( including taking out existing cable) LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded , 4 core,10 sqmm, after taking out/down old existing unserviceable from trenches / ducks/ road crossing and poles complete all as specified and directed. NOTE : Excavation and earth work, cable protection (GI Pipe), sand filling,cable joint shall be measured and paid separately under respective items of schedule.
All as per srl item No 12 here-in-before but size of 3.5 core, 25 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 35 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 50 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 70 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 95 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 120 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 185 sqmm.
All as per srl item No 12 here-in-before but size of 3.5 core, 240 to 300 sqmm.
Supply jointing and testing straight through, heat shrinkable jointkit suitable for PVC/ XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade of size 4 core,10 to 16 Sqmm and including taking from faulty portion in any situation/position complete all as directed.
All as per srl item No 21 here -in-before but size of 3.5 core, 25 to 50 Sqmm.
All as per srl item No 21 here -in-before but size of 3.5 core, 70 to 120 Sqmm.
All as per srl item No 21 here -in-before but size of 3.5 core, 185 to 300 Sqmm.
Supply, laying, jointing and testing in replacement (Including takingout existing cable) XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 Sqmm,11 KV grade (earth) for 11 KV (E) system, laid in trenches/ducts/encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed
All as per srl item No 25 here -in-before but size of 3 core,240 sqmm.
All as per srl item No 25 here -in-before but size of 3 core,185 sqmm.
All as per srl item No 25 here -in-before but size of 3 core,120 sqmm.
Supply, jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
All as per srl item No 29 here -in-before but size of 3 core,120 to185 sqmm.
Supply, jointing and testing, indoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
All as per srl item No 31 here -in-before but size of 3 core,120 to185 sqmm.
Supply, jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 11 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 240 to 300 Sqmm.
All as per srl item No 33 here -in-before but size of 3 core,120 to 185 sqmm.
Disconnecting the existing unserveceable/burnt MCCB from the cable taking out from panel board & supply & fix new MCCB,3pole 400 Amp 35 KA breaking capacity Adjustable type suitable for 415 volts,50HZ 3 Phase supply thermal magnetic release, fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB andconnecting with existing cable including thimble,nut bolt and washers etc complete.
All as per item No 35 above but MCCB of rating 250 Amp 25 KA breaking capacity 3 pole
All as per item No 35 above but MCCB of rating 200 Amp 25 KA breaking capacity 3 pole
Material and labour in replacement for GI pipe light grade laid in trenches for cable protection of size 50mm dia. complete all as specified and directed
Material and labour in replacement for GI pipe light grade laid in trenches for cable protection of size 80 mm dia. complete all as specified and directed
M&L for replacement of unserviceable jumper of ACSR Conductor with new jumpers of ACSR conductor of suitable size including binding properly on the existing OH line/ 4 pole structure with clamp, nuts & bolts etc.complete all as specified and directed.
M&L for disconnecting burnt end termination or portion of cable removing the cable from loop including necessary excavation & earth work, suitable size of thimble, LT tape, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals for 50 Sqmm to 70 Sqmm 3.5 core along with replacement of existing corroded Nuts bolts and washers with new GI nuts bolts and washers at LT cable to pole/LT panel/main switch/transformers complete all as specified.
All as per item No 41 above but of size 95 to 120 Sqmm.
All as per item No 41 above but of size 150 to 185 Sqmm.
All as per item No 41 above but of size 240 to 400 Sqmm.
M&L for boring of holes under road/pavement/hard standing by trenchless technology using ultra sound technique and necessary machine including material and labour for HDPE pipe of 160 mm dia suitable for 06 Kg/cm2 working pressure. Wall thickness of pipe not less than 6.5 mm.
M&L for danger notice board of 1.6 mm thick mild steel,vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size for HT 25 x 20 CM size complete.
S&F in replacement caution plate "CAUTION MEN AT WORK" of size 40 cmx15 cm made out of white acrylic sheet with Red coloured glow tape.
M&L for preparation of painted surface of floor mounted HT control panel for fixing of FLOURCENT REFLECTIVE LETTERING of approved colour and re-write the name/capacity/fed from each cope point HT etc in capital letters of size not less than 2 inch width and 3 inch height and works not exceeding 20 letter per panel all as specified and directed.
Disconnecting of all electric connection from the existing unserviceable/burnt ACB 800/1000 A four pole 415 Amps and dismantling/taking out ACB from LT panel board for repair at site including servicing and re assembling the ACBs after repair reconnecting of all connection including replacement of following parts of ACB for working as satisfication level complete all as specified and directed.
Supply and fix in replacement pole connector 800/1000 Amps 415 volts
Supply and fix in replacement Jaw contact 800/1000Amps 415 volts
Supply and fix in replacement Fixed contact 800/1000 Amps 415 volts
Supply and fix in replacement Hard ware Kit 800/1000 Amps 415 volts
Supply and fix in replacement moving contact 800/1000Amps 415 volts
Supply and fix in replacement Trip coil 220 volts
Demoletion of PCC from path any position and M&L for PCC in foundation filling and mass concrete type C2 (1:3:6) using 40 mm grded aggregate for foundation of pole complete all as specified
Demoletion of PCC from path any position andM& L for PCC type B1 (1:2:4) using 20 mm graded aggregate for pedestal of poles including use and waste of formwork complete all as specified
Supply, installation & commissioning and testing in replacement of SHF/VRLA Battery, Battery charge panel comprising 12 Nos. 2 Volts 100 AH tubular cell, self contained floor mounted sheet steel cabinet with two tiers for housing the batteries. The charging equipment will be operated from 240Volt +/- 10%, 50 c/s supply. The cabinet should be complete and internally wired auto/mannual switch. The charger unit should house, resstance control DC ammeter , Voltmeter and fuses, AC supply failure alarm. Complete accessories required for commissioning is included in the scope of work. DC distribution board comprising of 63 Amps DPMCB as incomer and 2 nos of 15 A DP MCB as O/G Battery Charger with batteries Automatic Float cum Bboost charger of 16 A to give 24 V DC output at 60 Ah capacity
Supply only following expendable items for replacement : CRC liquid 300 ml bottle.
cotton waste
Fuse wire 100 Amp
Fuse wire 60 Amps
Fuse wire 40/30 Amps
PVC insulation tape of thickness 0.125 mm 25 mm width 25 Mtr length.
HT insulation tape of thickness 25 mm width 25 Mtr length. Make : BIRLA 3M
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge
Vijay Electricals
mayur enterprises
Buddham Builders
Powerlite Engineers
Ridhi engineers and builders
DS CONSTRUCTION
Microsys Controls India
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .