Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC VILLAGE POST OFFICE BONDA TEHSIL RAMPUR BUSHAHR DISTT SHIMLA | RAMPUR BUSHAHR | SHIMLA | HIMACHAL PRADESH | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical VPO JEORI TEHSIL RAMPUR DISTT SHIMLA | - | Rejected-Technical L3 | |
| 3 | Rejected-Technical PADAM NAGAR RAMPUR BUSHAHAR | - | Rejected-Technical L2 |
Tender Value
₹8.2 L
EMD Value
₹17,000
Closing Date
12 Nov 2020, 5:00 pmClosed
XEN Elect Division No II
XEN Elect Division No II HPPWD Shimla-2
Providing power wiring in civil engineering block
2020_PWD_41968_1
ED.II.GA.Tender/20-21-5956-57 dated 21.10.2020
Open Tender
Electrical Works
Item Rate
180 days
District Shimla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Elect Division No II
₹17,000
15 Feb 2021
27 Oct 2020
13 Nov 2020
27 Oct 2020
12 Nov 2020
27 Oct 2020
Amount
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x2.5 Sq. mm.
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 25 sq. mm (3.5 core)
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, painting etc. as required.
Supplying and fixing electrical switch board,having 3No.of 5amp.switches and Socket on suitable size of meta lbox of 200 mmX150mmX75 mmdeep (nominalsize) onsurfaceor inrecess with suitable size phenolic laminated sheetcover inthefronti/cproviding and fixing 3No.5pin5/6 amp socket outlet and5/6 amp piano type switch, connection,paintingetc.asreq. (For light plugs) for computer
Supplying and fixing 30 Amps, 415 volts, TPN industrial socket outlet, 4-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 30 Amp TPN-MCB, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A.6 to 32 amps
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Double pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Triple pole & Neutral. Cat-A.
Supplying installtion testing and commissioning of wall/Floor mounted panle of suitable dimensions made from 2.0 mm thick CRCA sheet complete with incoming MCCB 100/63 A TP 25 KA TMR spreader links , copper bus bar 100/63A Amp and outgoing MCB TPN 32 Amp-1 Nos. and provision for MCB DB D/D of required ways in the panel as required complete in all respect
Supplying installtion testing and commissioning of wall/Floor mounted panle of suitable dimensions made from 2.0 mm thick CRCA sheet complete with incoming MCCB 63 A TP 25 KA TMR spreader links , copper bus bar 63A Amp and outgoing MCB TPN 32 Amp-1 Nos. and provision for MCB DB D/D of required ways in the panel as required complete in all respect
Supplying installtion testing and commissioning of wall/Floor mounted panle of suitable dimensions made from 2.0 mm thick CRCA sheet complete with incoming MCCB 40 A TP 25 KA TMR spreader links , copper bus bar 40 Amp and outgoing MCB TPN 32 Amp-1 Nos. and provision for MCB DB D/D of required ways in the panel as required complete in all respect
Nitin Krate
Libra Trader
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_61920.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .