Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.8 LQualified Make: LUMINOUS
Model: LUMINOUS 3KVA 46 BAHADUR MARG DEWAS DEWAS MADHYA PRADESH 455001 DEWAS MADHYA PRADESH 455001 | DEWAS | MADHYA PRADESH | 455001 | Make: LUMINOUS
Model: LUMINOUS 3KVA | L1 | Qualified | |
| 2 | L2₹1.9 L+₹11,060 (6.20%)Qualified Make: BPE
Model: BPE Niy 3 kva 3024 vah MF1103L6 2 years DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: BPE Niy 3 kva 3024 vah MF1103L6 2 years | L2 | Qualified | |
| 3 | L3₹1.9 L+₹13,560 (7.60%)Qualified Make: LUMINOUS
Model: LUMINOUS 3KVA 00 GAYATRIPURAM GAYATRIPURAM KASYA ROAD DEORIA UTTAR PRADESH 274001 | DEORIA | UTTAR PRADESH | 274001 | Make: LUMINOUS
Model: LUMINOUS 3KVA | L3 | Qualified | |
| 4 | L4₹2.0 L+₹22,055 (12.4%)Qualified Make: POWER ONE
Model: POWER ONE & UHF302A08 GF 3 F 12 KSSIDC BUILDING 5TH CROSS 1ST STAGE PEENYA INDUSTRIAL ESTATE BANGALORE | BENGALURU URBAN | KARNATAKA | 560058 | Make: POWER ONE
Model: POWER ONE & UHF302A08 | L4 | Qualified | |
| 5 | L5₹2.0 L+₹22,160 (12.4%)Qualified Make: BPE
Model: BPE Niy 3 kva 3024 vah MF1103L6 2 years AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE Niy 3 kva 3024 vah MF1103L6 2 years | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Aug 2018, 9:00 pmClosed
Online UPS Online UPS ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA 3.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT-PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 3024 3000
3024 Warranty for UPS (Years) 2 2
3 Movable trolly for Batteries Without trollery but with rack Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put Without With
Without 1/4 Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes - 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. ETDC(MH)/TR/T&M/138 3 - Type Test Certificate date 07-02-2006 - Name of Lab ETDC MUHALI - Address of Lab B-108 PH-8 MUHALI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramesan Karalanchalil 600009
HQ Dakshin Bharat Area Island Grounds Chennai 5 15
395847
GEM/2018/B/56027
Online UPS
15 days
Tamil Nadu; Chennai
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA 3.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 3024 3000 | - | - | - |
| 3024 Warranty for UPS (Years) 2 2 | - | - | - |
| 3 Movable trolly for Batteries Without trollery but with rack Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put Without With | - | - | - |
| Without 1/4 Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes - 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. ETDC(MH)/TR/T&M/138 3 - Type Test Certificate date 07-02-2006 - Name of Lab ETDC MUHALI - Address of Lab B-108 PH-8 MUHALI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramesan Karalanchalil 600009 | - | - | - |
| HQ Dakshin Bharat Area Island Grounds Chennai 5 15 | - | - | - |
Exempted
7 Aug 2018
28 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_395847.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .