Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 CrAccepted-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹5.2 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹5.4 Cr+₹23.7 L (4.56%)Rejected-Finance | ₹5.4 Cr+₹23.7 L (4.56%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹5.8 Cr+₹58.2 L (11.2%)Rejected-Finance | ₹5.8 Cr+₹58.2 L (11.2%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹6.0 Cr+₹75.6 L (14.5%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | ₹6.0 Cr+₹75.6 L (14.5%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹6.0 Cr+₹84.1 L (16.2%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹6.0 Cr+₹84.1 L (16.2%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹5.2 Cr
EMD Value
₹5.9 L
Closing Date
30 Apr 2022, 6:00 pmClosed
Chief Engineer , Bhopal Zone, Bhopal
HQ , Chief Engineer , Bhopal Zone, Bhopal
UPGRADATION OF ELECTRIC INFRASTRUCTURE AT BABINA UNDER GE BABINA
2022_MES_514019_1
CA NO CEBZ / BAB / TOKEN / 22 OF 2021-22
Open Tender
Civil Works
Lump-sum
546 days
Babina
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Garrison Engineer Babina
₹5.9 L
Yes
22 Jun 2022
16 Mar 2022
7 May 2022
16 Mar 2022
30 Apr 2022
19 Apr 2022
Amount
Note: (i) Please refer ''Schedule 'A' (BOQ) Notes'' before quoting the tender. (ii) Amount of ''Schedule of Credit" shall be deducted off line by the department.
GENERAL SUMMARY
Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule ‘A’ Part- I (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for ROAD PATH as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for COMPOUND WALL, SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part- IX (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SHEDS as listed in Schedule ‘A’ Part- X (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXACAVATION, EARTH WORK & SITE DEVELOPMENT as listed in Schedule ‘A’ Part- XI (Ref prepriced schedule attached seperately)
SCH 'A' Pt - XII (MISCELLANEOUS ITEMS) (Contains Ser item No 4.00 to Ser item No 8.02)
INTERNAL ELETRIFICATION NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III (internal Electrification) shall also be applicable.
S & F LED bulb 9 watt energy saving complete all as specified & directed
Supply and fixing in repair 18/20 W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 20 watts lamp fitted including wiring upto and terminal into ceiling rose ,complete all as specified and directed.
Supply and fixing light fitting Energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser. including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm, ,complete all as specified and directed.
S&F ceiling fan 1400 mm sweep BEE 5 star rating complete AC single phase 230 volts.including all fixing arrangement like hook ,pipe of suitable size ,complete all as specified & directed.
Supply and Fixing Exhaust fans AC single phase 230/240V of size 300 mm sweep, 1400 RPM heavy duty with louvre complete including with all arrangement of making holes on wall, making good and finishing of disturbed surfaces matching with the existing surfaces, necessary fixing arrangement such as fastener bolts, nuts, washers etc, of appropriate size complete all as specified and as directed
S&F sheet metal enclosure double door DB TPN 4 way concealed suitable for distribution boards when MCBs to be used as outgoing 100 Amp, 4 pole , 36 KA, 415 V,as incoming with suitable rated bus bar ,complete all as specified and as directed .
Supply and fix LED 15 W street light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminium IP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtr length with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesingle core PVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls / pole complete all as specified and directed.
EXTERNAL WATER SUPPLY NOTE:- For items of EXTERNAL WATER SUPPLY notes given at the beginning of Sch ‘A’ Part-IV ( EXTERNAL WATER SUPPLY ) shall also be applicable.
M&L for Valve Pit of size 45x45x60cm (internal dimensions), stone masonry construction, including all necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus soil to a distance n.exc 50m and depositing where directed, PCC in foundation of the mix (1:4:8), type C (Using 40mm graded crushed stone aggregate) stone masonry in cement mortar 1:4),rendering,12mm thick in cement mortar (1:4), internally finished even and fair and pointing flush externally as the work proceeding in the same mortar . Mild steel angle iron 75x75x6mm frame of MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed surface MS work with two coats of synthetic enamel paint of the tint as approved all the MS embedded in PCC with two coat of black bituminous paint suitable for 50mm dia , complete all as specified & directed..
EXTERNAL ELETRIC SUPPLY NOTE:- For items of EXTERNAL ELECTRIC SUPPLY notes given at the beginning of Sch ‘A’ Part-V ( EXTERNAL ELETRIC SUPPLY ) shall also be applicable.
M & L for cutting of stone road /hard standings of any type / size at site for laying of HT UG cable / protection pipe not exc 45 cm wide and n.exc 60 cm depth including making good the disturbed/broken surfaces of road/hard standing with matching to existing concrete & stone blocks as per direction complete all as specified and directed.
M & L for black top road cutting incl excavation in trenches for laying HT / LT UG cable in pipe not exc 45 cm wide and n.exc 60 cm depth or as per site requirement including making good the disturbed surfaces with cement concrete (1:3:6) type C-1 and top surface neatly finished as per existing to match with the existing complete all as specified and directed.
S & F of cable path indicator made up of precast RCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate of size 900X400 X 50 mm and 8mm steel bars in rcc dulyl painted with yellow colour and marked/written as HT cable as directed and fixed at 600 mm above and 300 mm below ground level along with cable route complete all as specified and directed. Note - Cost of earth work, PCC in foundation for fixing of route indicator, painting and writing over indicators included in the quoted rate.
Supplying, installing, testing and commissioning of Indoor arc flash protected horizontal draw-out with roll on floor type Vacuum Circuit Breaker Panel , rated for 11kV, 630Amp, 20kA/3-sec, Incoming VCB Panels, motorised confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 20kA for 1 sec, Accessibility Class LSC2B-PM Class, comprising of 630 Amp, continuous rated Copper busbars and droppers, 01 Nos. Rack-In-Rack-Out Handles, The complete panel incl. HT and LT chamber with wiring shall be manufactured by approved OEM at its own facility of make as per list of Make as per appendix "C'' attached. The each panel shall consist of following :- (a) 01 x Incomer Panel, each comprising of :- (i) 11 KV, 630Amp, 20kA/3-sec, horizontal drawout Vacuum Circuit Breaker as per IEC-62271-100 with roll on floor type Vacuum Circuit Breaker having 03 Nos. vacuum bottles of same make as of circuit breaker, motorized and spring charging mechanism (230V AC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24 V DC). (ii) Current transformers (CT) (1x2 core or 2x1 core type) dual ratio, resin cast 200/100/5+5 Amps rating, class 5 P10 for protection & class 0.5 for metering , 15 VA burden, short time rating not less than 18.4 KA for 3 sec, having IS :2705 marked suitable for 11 KV HT panel = 03 Nos.” (Description continued on Ser Item No 6.06)
(iii) Potential transformer (PT unit) three phase three limb, 11 KV draw out type, resin cast dry type, single ratio having primary 11 KV & secondary voltage 110 volts, 50 VA class-0.5, IS :3156, marked, with HRC fuses including necessary bus bar connection & wiring for metering etc. (iv) Metering Equipment including 01 x Analoge Voltmeter (Acc.Cl.0.5), and 01 x Digital Ammeter (Acc.Cl.0.5) with wiring. (v) LED Indications :- (aa) Breaker ON/OFF/TRIP/Spring-Charged, (ab) R-Y-B, (ac) DC Available LED with push-button (ad) AC Supply Fail (ae) Trip Circuit Healthy (vi) Control Equipment including :- (aa) 01 x TNC Switch, (ab) 01 x Local/Remote Switch, (ac) 01 x Emergency Trip Push Button, (ad) MCBs for AC and DC (af) Heater with Switch with Thermostat - 01 No (ag) 3-pin socket with ON/OFF switch - 01 No (vii) Flush mounted Auxillary Protection Relays incl:- (aa) Trip Circuit Supervision Relay, (ab) PT Fuse failure relay. (ac) Numerical EF/OC Relay draw out type indicating and tripping the breaker on faults over-current and earth-fault in any of the three phases. NOTE : (a) The above VCB consisting of two in comer shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on platform as recommended by OEM complete. (b) No any authorised channel partner of OEM manufacturing / assembling unit is allowed.
Supplying, installing, testing and commissioning of Indoor arc flash protected horizontal draw-out with roll on floor type Vacuum Circuit Breaker Panel , rated for 11kV, 630Amp, 20kA/3-sec, used as BUS COUPLER VCB Panels, motorised confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 20kA for 1 sec, Accessibility Class LSC2B-PM Class, comprising of 630 Amp, continuous rated Copper busbars and droppers, 01 Nos. Rack-In-Rack-Out Handles, The complete panel incl. HT and LT chamber with wiring shall be manufactured by approved OEM at its own facility of make as per list of Make as per appendix "C'' attached. The each panel shall consist of following :- (a) 01 x BUS COUPLER Panel, each comprising of :- (i) 11 KV, 630Amp, 20kA/3-sec, horizontal drawout Vacuum Circuit Breaker as per IEC-62271-100 with roll on floor type Vacuum Circuit Breaker having 03 Nos. vacuum bottles of same make as of circuit breaker, motorized & spring charging mechanism (230V AC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24 V DC). (ii) Bus trunking panel matching with VCB with copper bus bar of capacity 630 Amps duly insulated and with support insulators. (Description continued on Ser Item No 6.08)
(iii) LED Indications :- (a) Breaker ON/OFF/TRIP/Spring-Charged, (b) R-Y-B, (c) DC Available LED with push-button (d) AC Supply Fail (e) Trip Circuit Healthy (iv) Control Equipment including :- (a) 01 x TNC Switch, (b) 01 x Local/Remote Switch, (c) 01 x Emergency Trip Push Button, (d) MCBs for AC and DC (f) Heater with Switch with Thermostat - 01 No (g) 3-pin socket with ON/OFF switch - 01 No Note : (a) The abovebus coupler VCB shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on platform as recommended by OEM complete. (b) No any authorised channel partner of OEM manufacturing / assembling unit is allowed.
Supplying, installing, testing and commissioning of Indoor arc flash protected horizontal draw-out with roll on floor type Vacuum Circuit Breaker Panel , rated for 11kV, 400 Amp, 20kA/3-sec, Outgoing VCB Panels, confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 20kA for 1 sec, Accessibility Class LSC2B-PM Class, comprising of 600 Amp, continuous rated Copper busbars and droppers, 01 Nos. Rack-In-Rack-Out Handles, The complete panel incl. HT and LT chamber with wiring shall be manufactured by approved OEM at its own facility of make as per list of Make as per appendix "C'' attached. The Board shall consist of following panels:- (a) 01 x outgoing Panel, each comprising of :- (i) 11 KV, 400Amp, 20kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100 with roll on floor type Vacuum Circuit Breaker having 03 Nos. vacuum bottles of same make as of circuit breaker, motorized spring charging mechanism (230V AC) horizontal drawout , with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24 V DC). (ii) Current transformers (CT) (1x2 core or 2x1 core type) dual ratio, resin cast 100/50/5+5 Amps rating, class 5 P10 for protection & class 0.5 for metering , 15 VA burden, short time rating not less than 18.4 KA for 3 sec, having IS :2705 marked suitable for 11 KV HT panel = 03 Nos.” (Description continued on Ser Item No 6.10)
(iii) Metering Equipment including 01 x Digital Ammeter (Acc.Cl.0.5) (iv) LED Indications :- (a) Breaker ON/OFF/TRIP/Spring-Charged, (b) R-Y-B, (c) DC Available LED with push-button (d) AC Supply Fail (e) Trip Circuit Healthy (v) Control Equipment including :- (a) 01 x TNC Switch, (b) 01 x Local/Remote Switch, (c) 01 x Emergency Trip Push Button, (d) MCBs for AC and DC (e) Heater Switch with Thermostat - 01 No (f) 3-pin socket with ON/OFF switch - 01 No (vi) Flush mounted Auxillary Protection Relays incl:- (a) Trip Circuit Supervision Relay, (b) PT Fuse failure relay. (c) Numerical EF/OC Relay draw out type indicating and tripping the breaker on faults over-current and earth-fault in any of the three phases. Note : (a) The abovebus coupler VCB shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on platform as recommended by OEM complete. (b) No any authorised channel partner of OEM manufacturing / assembling unit is allowed.
Supplying , installation, testing and commissioning of 11 KV, 630 Amps having short circuit capacity 21kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 6 way, electrical and mechanically interclocked, comprising of 02 Nos motorized operated Load Break Switch and 04 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel tank with min. thickness 3 mm, IP 65 Degree of Protection , internal-arc classified 21kA/1sec, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit alongwith Bus-connected, fixed-type Auxiliary transformer shall include the following along with all necessary accessories and fittings as required at site. (A) 02 Nos. Incoming Load Break Switch module each consisting of following accessories :- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity - 50kAp -01 No (Description continued on Ser Item No 6.12)
(iii) Auxiliary contacts - 1NO + 1NC-01 No (iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing / replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 300 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 (vi) Right angle boots (push on type)-Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No (B) 04 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp-01 No (iii) Aux. contacts - 1NO+1NC-01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 150 Sqmm , 3 Core, XLPE aluminium cable termination in live-condition. Each Set of 3 (vi) Right angle boots (push on type)-Each set of 3. (Description continued on Ser Item No 6.13)
(vii) 3 O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol-01 No (viii) Associated ring-core cast-resin insulated CTs 50/1 Amp , 2.5 VA, 10P10 for protection (Each Set of 3)-01 Nos and CTs 50/1 Amp , 2.5 VA, 10P10 for protection (Each Set of 3)-05 Nos (ix) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (x) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (xi) Push button for breaker trip (xii) Shunt trip coil 24V DC - 01 (xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. (xiv) Emergency Trip Push Button - 01. (C) 01 No. Bus-connected, fixed-type Auxiliary transformer to provide required aux. supply and metering consisting of following accessories :- (i) 1-Ph (11kV/rt3):230VAC, 500VA Auxiliary transformer-01 No (ii) Power pack 24 volt DC comprising of dry cell batteries output 24 volt DC , input 230 Volt AC enclosed in MS sheet enclosure with LED indicators & other accessories & wiring.(iii) BLANK (iv) HRC fuse-links for primary side isolation and AC/DC MCBs for secondary isolation-01 Set (v) Voltmeter & RYB LED Indications to confirm AC/DC supply availability-01 Set (vi) Anti-condensation space-heater-01 No (vii) LED lamp for illumination and 3-pin socket with switch -01 No (D) Additional equipment deliverd separately or mounted seperately :- (i) Operationg Handle for Manual Isolator/Disconnector/Earthing Operation-02 Nos (Description continued on Ser Item No 6.14)
(ii) Standard Manometer -01 No (iii) Operation and Maintenance Manual -01 No (iv) Installation & Commissioning Manual -01 No (v) Cable crimping tool (standard) -01No (s) 3 O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. (t) Resin cast ring core protection CT plate mounted type : 100/5-5 A, 5P10, 2.5 VA - 3 Nos (u) Mechanical ON/OFF/EARTH/Spring charge Indication (v) Cable boxes should be Arc Proof interlocked with respective Earthing Switches. (w) Right angle non-touch proof Termination boots - 1 Set (R,Y,B). Note :- 1. RMU shall be placed on PCC plateform with PCC 1:2:4 and all around brick work of size and design recommended by manufacturer /or as directed by engineer in charge (height of same shall be minimum not less than 60 cm above from surrounding ground level) and the cost of the same shall be deemed to be included in unit quoted rates. 2. (a) The above module consisting of two Load break Switch and 04 VCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on plateform as recommended by OEM complete. (b) Cost of provn of plinth for RMU as per OEM drawing is deemed to be included in the cost. (c) No any auth channel partner of OEM manufacturing/assembling unit is allowed.
Description all as per item No. 6.11, 6.12, 6.13, 6.14 here in before but RMU (Ring main unit) 8 way consisting of combinations of 2 Nos. fixed manual Load Break Switch of capacity 11 KV 630 Amp as incoming panel & 6 Nos fixed type manual Vacuum Circuit Breaker capacity 11 KV 630 Amp as outgoing panel . The configuration of the RMU will 2 load break switch as incomer and 11 KV 6 Nos VCBs as outgoing , complete all as specified and directed. NOTE FOR SER item No 6.05,6.06,6.07,6.08,6.09, 6.10, 6.11, 6.12, 6.13, 6.14,6.15 :- Factory inspection shall carryout prior dispatch at factory premises by rep as detailed by accepting officer. The contractor has to arrange the same without any financial effect & the rate quotes against the respective item is deemed to be included this factor..
Supplying, installation, connecting, testing and commissioning of outdoor type distribution Transformer of 63 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound , Level -II (energy saving) step down, floor mounted complete with first filling ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group DYN -11 ,complete all as specified and directed. Note - (i) The ambient temprature shall be 48 degree Centigrade when measured by the resistance method after continuous full load run . (ii) The transformer shall be complete with standard fittings all as specified and conforming to IS:335 of 1993 for oil and IS: 1180 Part -I of 2014 for transformer and comprising of followings:- (Description Continued on Ser item No 6.17)
(i) One No cable box on LV side (secondary side) consisting of 04 Nos of porcelain bushing with bushing rods and another cable box on HV side (primary side) consisting of 03 Nos of porcelain bushing with bushing rods etc complete with nut, washers, cable gland etc. (ii) Oil conservator tank with filter type drain valve and oil level gauge. (iii) Oil level indicator with minimum and maximum marking (iv) Dehydration silica gel breather assembly with first fill of dehydrating agent and oil seal. (v) Explosion vent with diaphragm complete. (vi) Thermometer pocket on tank cover. (vii) Dial type thermometer vapour pressure having range 0-120 degree C with max reading pointer max temp indicator and resetting device. (viii) Rating plate with terminal marking. (ix) 02 Nos earthing terminal on tank and cover for fixing earth strip of size 32 x 6 mm. (x) Oil level gauge and oil drain filter valve. (xi) Lifting hook. (xii) Oil filler hole with cap /plug with connection complete. (xiii) Air relief valve plug. (xiv) Detachable rollers - 04 Nos (xv) Extra bushing for Neutral out side the cable box for independent earthing for neutral earth. (xvi) First fill of fresh transformer oil confirming to relevant IS and tested up to 40 KV die electric strength.
Supply, installing, testing and commissioning, factory made and tested , CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following, complete all as specified & directed and consisting of the following :- (a) Aluminium bus bar four Nos 150 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming :- (b) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity Icu- 35 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) (Description Continued on Ser item No 6.19)
M&L for laying 20 mm graded stone aggregate & stone dust in substations in such a way that after removing of unwanted grass from substations and then levelling at zero level and laying of stone dust of 50 mm thick at an initial layer and then laying of 20 mm graded stone aggregate 100 mm thick over the stone dust. The quoted rate also includes cleaning and levelling and filling of sub station before laying aggregate complete all as specified & directed.
S&F of kiosk box for luminaires ,weather proof made out of PVC/HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of 4 pole copper connectors of 16 Amps with 6 Amp MCB single pole , of minimum size of panel is 300x200x125mm, IP 54 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box ,complete all as specified and directed.
M&L for new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 70/72 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including s&f of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to LED light throgh copper connectos ,complete all as specified and directed.
S & F of GI brackets for street light fitting fabricated with GI tubing 32 mm dia for LED Street lights medium grade 1.2 mtr length and bending to angle of 120 degree incl mild steel flat iron clamp fabricated with mild steel flat iron 30 x 5 mm with nut, bolt & washers suitable for fixing of GI bracket on existing poles , complete all as specified and directed.
ROAD PATH NOTE:- For items of Road & Path notes given at the beginning of Sch ‘A’ Part-VI ( ROAD PATH ) shall also be applicable.
M&L for sand stone pattie edging of roughing squared stones of 50 to 65 mm thick and 300 mm deep , 50 to 60 cm length jointed struck flush , complete all as specified and directed.
SEWAGE DISPOSAL NOTE:- For items of SEWAGE DISPOSAL notes given at the beginning of Sch ‘A’ Part-IX ( SEWAGE DISPOSAL) shall also be applicable.
M&L construction of Soakage Well of size 1.80 m dia and 3 m depth, including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M 25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M 25 / SFRC cover, interconnecting pipes of RCC / DWC complete filled with brick bats, complete all as specified and directed (Pl refer attached TD for additional details)
M&L RCC Septic tank with effective depth of 1.5 meter and overall depth of 3 meter for 10 users. designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete all as specified and directed.(Pl refer attached TD for additional details)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .