Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being lowest Bidder | |
| 2 | L2₹27.5 L+₹29,140 (1.07%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest Bidder | |
| 3 | L3₹30.9 L+₹3.7 L (13.6%)Rejected-AOC BIR SARDALIA RESIDENCY AIR FORCE ROAD BARYAL UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC 3rd lowest Bidder | |
| 4 | L4₹31.2 L+₹4.0 L (14.6%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC 4th lowest Bidder | |
| 5 | L5₹31.4 L+₹4.2 L (15.5%)Rejected-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L5 | Rejected-AOC 5th lowest Bidder |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
6 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(Army) Dhar Road
GE(Army) Dhar Road
PROVN OF 130 X SECURITY LIGHTS ALONGWITH SECURITY WALL OF DHAR ROAD GARRISON UNDER GE ARMY DHAR ROAD
2023_MES_622489_1
8069/NIT-59/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE(Army) Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE(Army) Dhar Road
₹82,000
Yes
5 Jan 2024
10 Oct 2023
8 Nov 2023
11 Oct 2023
6 Nov 2023
30 Oct 2023
Amount
Supply, laying connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core completed all as specified and directed by Engr-in- Charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core completed all as specified and directed by Engr-in- Charge
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core of size 4 Sqmm encased in and including rigid PVC conduit pipe medium grade laid along pole duly fixed to pole with & including 20 x 3 mm aluminium strip pieces tied with GI bolts, nuts & washers at interval of not more than 1.0 mtr apart all as specified and directed by Engr-in- Charge
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in any type of soil for laying of cable/errection of poles etc complete all as specified and directed by Engr-in- Charge
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick completed all as specified and directed by Engr-in- Charge
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point completed all as specified and directed by Engr-in- Charge
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed by Engr-in- Charge Note: Punned thickness shall be considerd for measurment purpose
S & L brick burnt for protection of cable sub class B bricks laid dry flat across the cable with length of whole brick complete completed all as specified and directed by Engr-in- Charge
Supply and fixing on wall security light fitting not less than 60watt, 230Volts AC outdoor type with high presure die cast aluminium housing, corrosion resistant with heat resistent glass cover impact strength not less than IK-07 duly fixed with DC driver, LEDs with lens, suitable heat sink for thermal management, PVC connectoe etc with CRI not less than 70, ingress protection not less than IP-66, THD not more than 10% , system lumen not less than 6600, surge protection not less than 4KV, Power factor >0.95, CCT not less than 4000◦K complete all as per Cat/ rpoduct code No LRO8-781-XXX-57-XX of WIPRO or TRP-409-60-57-SL-GL-NSG of CROMPTON or ENDURAOMNIPLUSSL60WLED757SAYTOPC of Havell's or ENDURASUNDOWNSL60WLED765PASYBOTG of Philip[s or SMIx1ECAC70/40N/ST/C1/PC1/U48/R7035/ of GE lighting
S&F Bracket made out of galvanised steel tubing light grade of size 40mm bore, not less than 1.5 mtr long, bent to shape at an angle of 120 degree as per requirement with 02 Nos mild steel clamps made out of 25mm x 4 mm flat iron and mild steel fastners 2 Nos each for one clamp of size at required at site complete with suitable size nuts, bolts and washers etc incl fixing on wall complete all as specified and directed by Engr-in- Charge
S&F SMC junction box of size 250mm x 200mm x 105mm size outdoor type, weather proof, shock/rust proof,termite resistant, fire retardant,made out of PVC sheet not less than1.8 mm thick with front side hinged, having locking arrangement with nuts , bolts & washers complete having arrangement for entry & exit of incoming and out going cables/wires etc complete comprising of the followings complete all as specified & directed by Engr Incharge. :- (a) Bus bar with two aluminium strips, 100 Amps capacity mounted insulators, including PVC wires of suitable size from bus bar to MCB (b) MCB SPN 10 Amps - 01 No (c) Clamps made out of 25mm x 3mm flat iron duly fixed with nuts & bolts complete all as specified and directed by Engr-in-charge.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level welded to galvanized iron strip of size not less than 30mm X5 mm as earthing lead including tarring of welded area protected by GI pipe medium grade 50mm bore for protection of GI earth strip and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories such as nut, bolts, washers , nipple, wire mesh/screen funnel etc and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electrical plate No. 3 of SSR Part-I completeincluding testing of earth resistance complete all as specified & directed by engr-in-charge.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nuts, bolts, reducers, nipples, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB compete all as specified as shown in electrical plateNo. 3 of SSR Part-I and testing of earth resistance as required complete all as specified & directed by engr-in-charge.
RAVI KUMAR
SARDALIA CONST CO
K S BUILDERS
MOHAN LAL AND SONS
FANGALIA TRADERS
PROACH ASSOCIATES BUILDERS & ENGINEERS
GURU KRIPA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .