Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | Admitted-Finance |
| 2 | Admitted-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | Admitted-Finance |
| 3 | Admitted-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | Admitted-Finance |
| 4 | Admitted-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | Admitted-Finance |
| 5 | Admitted-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | Admitted-Finance |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
14 Oct 2021, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
REPAIR AND MAINTENANCE OF DUCTABLE PACKAGE CASSETTE AC AND OTHER CONNECTED WORKS IN CVRDE AVADI
2021_MES_475970_1
8450/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
21 Oct 2021
17 Sept 2021
16 Oct 2021
17 Sept 2021
14 Oct 2021
30 Sept 2021
17 Sept 2021 - 30 Sept 2021
Amount
M&L for general service of package/ cassette type AC unit 4/3 Ton capacity installed at ground / first floor by cleaning outdoor and indoor unit area by blower, cleaning condersor coil unit ,Indoor cooling coil unit with water/chemicals, filter cleaning , cheking electrical wiring, tighting wires apply proper tags, replace copper lugs,insulation tape over bare terminal and trouble shooting for any gas leakage with nitrogen and arresting leakage, recharging with required qty of R22 gas including necessary welding works to maintain required temperature and testing complete all as specified and directed. Note:(i)Servicing of Acs shall be carried once in three month per AC Unit. (ii) Serve record to be submitted for claming payment and rate including of service slip etc..
supply R22 gas refrigerant
supply and fix copper pipe 1/4 22SWG
supply and fix copper pipe 1/2 22SWG
supply and fix condensate drain pump 230V suitable for cassette AC 4/3Ton complete all as specified.
supply and fix copper cooling coil suitable for R22 gas 50-90degree. rated working pressure 150-300PSI, 50-90degree suitable for cassette AC 4 Ton complete all as specified.
supply and fix copper condensor coil suitable for R22 gas rated working pressure 150-300PSI, 50-90degree suitable for cassette AC 4 Ton complete all as specified.
supply and fix fan blade suitable for 4 Ton casstte AC outdoor unit .
supply and fix fan blade suitable for 3 Ton casstte AC outdoor unit .
supply and fix Indoor unit blower motor suitable for cassette AC 4 Ton complete all as specified.
supply and fix indoor unit fan motor suitable for cassette AC 3 Ton complete all as specified.
supply and fix Outdoor unit motor suitable for cassette AC 4 Ton complete all as specified.
supply and fix Outdoor unit fan motor suitable for cassette AC 3 Ton complete all as specified.
supply and fix U/S power contactor 3 phase 3 Pole 40A capacity complete.
supply and fix copper cooling coil suitable for R22 gas 50-90degree. rated working pressure 150-300PSI, 50-90degree suitable for cassette AC 3 Ton complete all as specified.
supply and fix copper condensor coil suitable for R22 gas rated working pressure 150-300PSI, 50-90degree suitable for cassette AC 3 Ton complete all as specified.
supply and fix sensor for 3.0/ 4.0 ton cassette type cooling coil control.
supply and fix sensor for 3.0/ 4.0 ton cassette type room temperature control
supply and fix sensor for 3.0/ 4.0 ton cassette type float and manual mode control
supply and fix three phase Bakelite cable connector 10 way 40 Amps capacity.
supply and fix PCB suitable for 4.0/3.0 Ton cassette type AC suitable for as per site requirement all as directed
supply and fix replacement running capacitor 50mfd 415 Volt all as directed.
supply and fix starting capacitor 80/100mfd 415 Volt all as directed.
supply and fix starting relay suitable for 3.0 /4.0 Ton cassette type A/C all as directed.
supply and fix thermostat for 3.0/4.0 Ton cassette type AC all as directed.
supply and fix wiring kit suitable for 3.0 / 4.0 Ton cassette type A/C all as directed
supply and fix discharge valve for 4 TR cassette type Air conditioner
supply and fix discharge valve for 3 TR cassette type Air conditioner
supply and fix Suction valve for 4 TR cassette type Air conditioner
supply and fix Suction valve for 3 TR cassette type Air conditioner
supply and fix expansion valve for 4 TR cassette type Air conditioner
supply and fix expansion valve for 3 TR cassette type Air conditioner
supply and fix driyer unit for 4 TR cassette type Air conditioner
supply and fix driyer unit for 3 TR cassette type Air conditioner
supply and fix filter unit suitable for Indoor unit cassette type 3/4Ton complete.
supply and fix and fix Pvc pipe size 25mm suitable for cassette type AC drain all as directed
supply and fix and fix NUF insulation for copper tubing suitable for cassette type AC all as directed
S&F in replacement PVC cable 4 core PVC insulated 2.5 Sqmm copper conductor 1100V all as directed
S&F in replacement MCB three Pole 40 Amps 415Volt 3 phase all as directed
M&L for taking down unserviceable Scroll compressor 4Ton capacity including disconnect suction and discharge connections, transporting to workshop dismantle the unit by welding cut the outer frame, remove the burnt winding and rewind with super enameled copper wire including insulation varnishing etc assemble the outer frame by welding, brazing and testing unit transporting fixing in outdoor unit and testing the AC unit complete all as specified and as directed.
M&L for removing old paint and apply one coat of primer & two coat of synthetic enamel paint outdoor unit as exiting colour including writing letters/marking arrow discharge/suctiuon line, Indoor cassette unit all as specified.
M&L for arresting of water leak in the indoor unit of cassette type AC unit of 3/4 ton by necessary repair works including all accessories complete all as specified and as directed by Engineer-in-charge.
M&L for submain wiring with PVC insulated, PVC unsheathed cable, single core, stranded, copper conductor cable 4 x 6.0 Sqmm size, 1100V FRLS grade, drawn into rigid non-metallic PVC conduit 25mm pipe ISI marked with 1 x 4.0 Sqmm unsheathed, stranded copper 1100V FRLS grade cable for continuous earth wire, including taking down the old wiring complete all as specified and directed by Engineer-in-Charge. Note: 4 run of 6 sqmm and 1 run of 4 sqmm and i run PVC conduit shall be measured as one unit length.
BKR Enterprises
SAMYDOSS CONSTRUCTIONS
KRISHNA ENTERPRISES
rc enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .